HomeMy WebLinkAboutEngineered Plan - 2001BMI"CMICZ TOP OF FOUNDATION. ELEV. = 00.00 10 FT. MINIMUM (ASSUMED) 28" 4" CAST IRON PIPE 10" (OR EQUAL) MINIMUM ' PITCH 1/4" PER FT. ' ELEV. _ ELEV. _ _97.67 _ INTERIOR PIPING IS TO BE GAS ELEV. _ _ PLUMBED TO EXIT AS SHOWN NOT REQUIP,ED I ELEV. _ _9S 70_ LIQPUID OUTLET ELEV. = I 4 FEET 14 INCHES 5 FEET 19 INCHES 6 FEET 24 INCHES 7 FEET 29 INCHES 8 FEET 34 INCHES I 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE CONCRETE COVERS' 4" SCHEDULE 40 PVC PIPE MIN. IRITCH 1/8" PER FT. 6" MAX. FLOW LINE , I 10" COLOR 2" LAYER OF I -THIN. i ' ELEV. _ _ - ° _96.45- LE �'L .60 MAX. WASHED STONE GAS ELEV. _ _ ° 95_45 6" SUMP ELEV. _ _95.28 NOT REQUIP,ED BAFFLE DISTRIBUTION LOAMY SAND CONCRETE ELEV. = ANCHOR 95.60 BOX Q_ (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED 1500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) I SOIL ABSORPTION WELL N A 3/4" TO 1 1/2" CLEAN ZONE _ SYSTEM (SAS) DOUBLE WASHED STONE LOCATION MAP ADJUST _ FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM PROFILE -_-_.-- NOT TO SCALE _6Q_ x 98.83 x 97.94 C- CLEAN SAND HORIZ LOAM AND SEED . COLOR 2" LAYER OF OTHER 1 /8": TO 1/2 A .60 MAX. WASHED STONE VENT X MIN. NOT REQUIP,ED Z 1 CU. FT. OF LOAMY SAND CONCRETE a) ANCHOR 95.60 C o ° ' 10"° ° ELEV. o- = 94.27 ------ 4 HIGH CAPACITY INFILTRATORS WiTH 5% COBBLES STONE IN A z JOB N0. 5246-00 11' X 36' X 10" TRENCH FORMATION •67 I SOIL ABSORPTION WELL N A ZONE _ SYSTEM (SAS) INDEX LOCATION MAP ADJUST _ USGS PROBABLE WATER TABLE ELEV. = ------ OBSERVED WATER TABLE ( / % ) ELEV. = -_-_.-- BOTTOM OF TEST HOLE ELEV. = _6Q_ X 98.05 \ X'98.60 X 98.05 \\ 99.0 \ r Z t 77\ 4' C 10' 9.38 �M 1500 GALLON SEPTIC TANK 0 rn �o N •D. BOX SOIL TEST x 98.13 '___ll 99.04 x 97.79 LOT 21 14,750 -S.F. • x 98.60 x 97.75 0 04 \ SPS X 98 00 E ,2•�8 IR�� GR EE PANG cN�P a c c ► [D) DEC 1 9 2091 L-LHEALTH DEPT. LEGEND: EXISTING SPOT ELEVATION 0010 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 00.0 FINAL CONTOUR 00 SOIL TEST LOCATION UTILITY POLE TOWN WATER CATCH BASIN GAS LINE CLEAN OUT C y CESSPOOL C.P.0 SOIL TEST DATE OF SOIL TEST OST. 31, 2001 -__- SOIL TEST DONE BY �4YFEIEf�EN�I��F�f3Lr1G WITNESSED BY-A._VQN HONE______ OBSERVATION HOLE 1 ELEV.=__98.60 PERCOLATION RATE ___<__2 __ MIN./INCH AT ___LZ _ INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-7 A LOAMY SAND 10YR5/1 NO ROOTS 7-25 B LOAMY SAND 10YR7/6 ROOTS 25-132 C MEDIUM SAND 10YR8/1 SCALE 1 " = 20' 5% COBBLES NO WATER ENCOUNTERED AT __132_ ELEV. DESIGN CALCULATIONS NUMBER OF BEDROOMS 3 GARBAGE DISPOSAL UNIT (TO BE REMOVED) --NOL- TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X _3 BR.) __334_ GAL./DAY , REQUIRED SEPTIC TANK CAPACITY GAL. ACTUAL SIZE OF SEPTIC TANK _1500 GAL. SOIL CLASSIFICATION ._- DESIGN PERCOLATION RATE <_-5-_ MIN./IN. EFFLUENT LOADING RATEQJ_f GAL./DAY/S.F. LEACHING AREA 4_74_33 SQ. FT. (11X36)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) -91 QQ GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY 55LQQ GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YYA$9 9_U_R -___ RULES, AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. .4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH OR--ZCNINC=-RECULA TICKS. CAINrp / Acpt (CANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY; EXCAVATION CONTRACTOR IS TO CALL I"DIG-SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE .BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE c____. 9. LOT IS SHOWN ON ASSESSORS MAP �g�__ AS PARCEL __87__. 10. EXISTING CESSPOOLS ARE TO BE PUMPED AND BACKFILLED. Vrl � S4 4 .Za�... tSrr ' sV/ T A. � . APPROVED: BOARD. OF HEALTH 4 DATE AGENT C: \S8\PROJ\5246-00\DWG\5246-00,DWG 0 2001 SWEETSER ENGINEERING GREAT WESTERN .__4 0 0 o 0 o LOCUS v_ Z C G'REEG PROPOSED SEPTIC DESIGN FOR MILUM BEARD PROJECT LOCATION LOT T n1g1 21 104 CLAPPING . GREEN CIR., S.X. S ,° MVGLPMCRbVG 235 GREAT WESTERN ROAD P. 0. BOX 713 508= SOUTH DENNIS, MASS. 398- 3922 02660 DATE OCT. 31, 2001 SCALE 1 " = 20' JOB N0. 5246-00 REVISED LOCATION MAP REVISED SHEET 1 OF 1 C: \S8\PROJ\5246-00\DWG\5246-00,DWG 0 2001 SWEETSER ENGINEERING