Loading...
HomeMy WebLinkAboutEngineered Plan - 2017PRECAST H-10 RISERS (TYP.) 2'0 *32.1' ,.�• 31.49' (J-% SLOPE) FOUNDATION- 10' - ALL SYSTEM SHALL SYSTEM PROFILE MARKED WTHCMAGNETICTTAPE OR BE 1 (NOT To SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE 35.0' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 34.5' NOTE: 2" MIN. WALL BLOCKS OR THICKNESS REQUIRED MORTAR ALL PRECAST RISERS 4"OSCH40 PVC COMPONENTS PIPES LEVEL 1ST 2' H-10 <...• .. . < ENDS . BE0IFT. 10" 1500 GAL H-10 14." ,,, a,�,_o�o� , SIDES J� )o°o°o°c TEE SEPTIC TANK TEE 1 24' ;0.-° ° °-°-°-° °�°O°�°� a�D0a��00 �� 000•'�I�®��®����� �°°o°000° 000o O o0o0o00 �O°O°0°00 M=IF �I�aa al� 000000 ���al�oao ��a X00000000 GAS BAFFLE ::: 1°°°000°°°°° N >°o°o°o°o 0°0°000° ooa000r�oao® 00000° �o®®®®®®�®a :0000 >00°0°0°0 00000,00000000 LIQ. LEVEL (ACME OR EQUAL) 31.11' 30.94 ° 0 0 ° ° ° ° ° ° 0,6- Doo°O°000000000°°°°O°O°O°O°O°�°O°O o° 0 0 0 000 0 0 0 0 0 0 0 H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. P.,O„n_o.o 0 0 00°o.o_�_°_0_0.0 0 • 3/4"-1-1/2" DOUBLE WASHED STONE- '( ) 2 UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 30' X 9.83' COMPACTION. (15.221 [21)LO LEGEND- 99- EGEND (-L-7. SLOPE) (-!-% SLOPE) SEPTIC TANK 13' D' BOX 16' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS II PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM Sy- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 'VING F¢ BEDROOM 34" TEST HOLE 2YYYi SLOPE OF GROUND UTILITY POLE FLOOR PLANS FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 2/1/17 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. C 1 34.8' A LS 7" 1OYR 4/1 I= GARAGE PORCH KITCHEN Lm BEDROOM B 00 � LS X/t vali fo IMPAIR OF SEPTIC SVS1 m 'VING F¢ BEDROOM 34" 10YR 4/4 32.0' ROOM Wnin9 C FLOOR PLANS PERC NOT TO SCALE MS 2.5Y 7/6 132" I ( 23.8' NO GROUNDWATER ENCOUNTERED LICE #17-0i4 LEACHING FACILITY LOT 10,000 SF C T./ EXISTING DWELLING TOF = 35.1 TH 1 tvo o > >s, ~� 400,\� Scale:1 "= 20' 0 10 20 30 40 50 FEET •CAUTION ELECTRIC LINES L 7 4i NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 31:63' 6: "CONSTRUCTION :DETAILS 70 BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY 28.8' OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF 23.8' BOTTOM TH-1 WORK. NO GROUNDWATER FOUND NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 88 PARCEL 182 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SITE IS LOCATED WITHIN A ZONE II AND REMOVED OR PUMPED AND FILLED WITH CLEAN 2 BEDROOM DEED RESTRICTION REQUIRED SAND. SYSTEM DESIGN: % GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK S LEACHING: SIDES: 2 (30 + 9.83) 2 (.74) = 118 GPD BOTTOM 30 x 9.83 (.74) = 218 GPD TOTAL: 454 S.F. 336 GPD of USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) G WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' / VED BETWEEN UNITS ., i h � ,��IDECK /GARAGE " F OHE � c �0 �30 00 � R X/t vali fo IMPAIR OF SEPTIC SVS1 m Whites Poth 0�a Be0C0� 0/0' Townhouse Rd o Wnin9 G moo o, Locus °d amm r S,o l t. 7co6 y< `rc o -9S a CO t. Bes o O� HOZelmOor CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF 23.8' BOTTOM TH-1 WORK. NO GROUNDWATER FOUND NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 88 PARCEL 182 12. EXISTING LEACHING FACILITY SHALL BE PUMPED SITE IS LOCATED WITHIN A ZONE II AND REMOVED OR PUMPED AND FILLED WITH CLEAN 2 BEDROOM DEED RESTRICTION REQUIRED SAND. SYSTEM DESIGN: % GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS @ 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 1500 GAL. SEPTIC TANK S LEACHING: SIDES: 2 (30 + 9.83) 2 (.74) = 118 GPD BOTTOM 30 x 9.83 (.74) = 218 GPD TOTAL: 454 S.F. 336 GPD of USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) G WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' / VED BETWEEN UNITS ., i h � ,��IDECK /GARAGE " F OHE BENCHMARK: � CBDH ELEVATION � ,/z y MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #29 NIGHTINGALE DRIVE SOUTH YARMOUTH, MA .PREPARED FOR =35.5 NAVD88 / ESTATE OF LAWRENCE OBRIEN r• -Z -") -1 -7 DATE DANIEL A. OJALA, P.E., P.L.S. DATE: FEB 7, 2017 off 508-362-4541 fax 508-362-9880 I downeape.com d0W8 AfPe eftkeerinv, inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 17-014 1 APPROVED /Board vali fo IMPAIR OF SEPTIC SVS1 m due t tate and Local septic variances. of Health reVbw and approval is required for any future addrtion. /renocxtions/alterations to sewage facilities and/or A actor es/(IN+elling. Yarmiiutl*rt HeaHHl//ter l)cp:.rr•t\@mento/' �/�J:�l00 7 a c Rafe BENCHMARK: � CBDH ELEVATION � ,/z y MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #29 NIGHTINGALE DRIVE SOUTH YARMOUTH, MA .PREPARED FOR =35.5 NAVD88 / ESTATE OF LAWRENCE OBRIEN r• -Z -") -1 -7 DATE DANIEL A. OJALA, P.E., P.L.S. DATE: FEB 7, 2017 off 508-362-4541 fax 508-362-9880 I downeape.com d0W8 AfPe eftkeerinv, inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 17-014 1