Loading...
HomeMy WebLinkAboutEngineered Plan - 2016• PRECAST H-10 RISERS (TYP.) 20 22.57 J° 000. NOTE: ALL INTERIOR PLUMBING TO BE RE—ROUTED TO LOCATION SHOWN ON PLAN VIEW. PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 25.5'1 MINIMUM .70 OF COVER OVER SYSTEM PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 26.0' %1, NOTE: 2" MIN. WALL THICKNESS REQUIRED BLOCKS OR 4"0SCH40 PVC MORTAR ALL PRECAST RISERS 6" MIN. SUMP PIPES LEVEL 1ST 2' COKiPONENTS H-10 12" MIN. INT. DIM. ENDS (TYP•) \/'S EL 22.0 SIDES 23.0' 10" 1500 GAL H-10 14" ° ': ° ':. .... TEE SEPTIC TANK TEE 2.32' ° ° ° ° �ElE3� �0�rn ��m0 —�1! 0000000 00 °°°°°°°°°°°° WATERIEST D'BOX >00000000 . ooaa000a000 ao�aa�ao�oo 00000000 0 0 0 0 0 0 O �o°o°o°o° p p 0 !� O !� O 0 0 0 0 0 p p (� 'o°o°o°o° GAS BAFFLE°°°°°°°°°°° FOR LEVELNESS °°°°°°°° a�ao�a�a000 aoaaa������ ;°°°°°°°° ° >00000000 0�00�o��ocia o�aaa�o�ooa .00000000 22.27' 22.10' °°°° °°°° 20.0 4' LIQ. LEVEL (ACME OR EQUAL) °°°°°°°° °°°°°°°° °°°o°o°o°o°oo°oo°°°°°o°°°°°000°oo°°o°o°oo`' °o°o°°,°,°°,o;°°,°�°o°000°�°°°,°o°°°°°,°;°o°o°° H-20 500 'GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) in r0 (2.2 % SLOPE) FOUNDATION 15' — LEGEND- 99— EGEND 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 ASSESSORS MAP 91 PARCEL 165 TEST HOLE 20.. SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BRUCE G. MURPHY DATE: 12/29/2016 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 24.5' A LS 12" 1OYR 3/2 B LS 30" 1OYR 5/6 22, C PERC MS 1OYR 7/4 120" 14.5' NO GROUNDWATER ENCOUNTERED INCL' #16-411 ( 1 % SLOPE) (1 % SLOPE) SEPTIC TANK 5' D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM Scale:1 "= 20' 0 10 20 30 40 50 FEET 14.5' BOTTOM TH-1 NO GROUNDWATER FOUND LEACHING FACILITY VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5') (1b): REDUCTION IN SETBACK, SAS TO FOUNDA11ON (20' TO 17.2') DATE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -2Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. rmit valid for REPAIR 01, S.f 1 TR7. SYSTEM` NI..Y, hire. to State and Local septic variances. Bo d of Llealth review and approval is required for an future ad(litions/reno%ations/alterations to septi, ge facilities and/or structures/dN%elling. L Yarmouth Ileattb II)epartrnent APPROVED/ � r `avme Date LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 91 PARCEL 165 N _> gjj Z d ix SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S. F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #51 HARBOR HILL RUN SOUTH YARMOUTH. MA PREPARED FOR B&B EXCAVATION / MARCHESE DATE: DECEMBER 30, 2016 off 508-362-4541 fax 508-362-9880 downcope.com 00Wn CQ,D.e ell h)ed* fin.►, h7 C. civil engineers S land surveyors I 939 Main Street ( Rte 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 16-411