Loading...
HomeMy WebLinkAboutEngineered Plan - 2017- - 100- -- EXISTING CONTOUR N x 100.98 EXISTING SPOT GRADE -W-EXISTING WATER SERVICE -G-EXISTING GAS SERVICE a -6.H. bl- OVERHEAD WIRES TEST PIT s 0 BENCHMARK Ra LEGEND 0 a Z LOCUS LOCUS MAP a NOT TO SCALE LO � loo.le %� � � 7 Ne EXISTING SEPTIC TANK TOP OF TANK, EL. =103.78 INV.(OU T)=102.45f \� 4\ \ '100.94 O � 106.40 `` \ \ 1 V `\ �.�x 101.29 105.A5 1 101.69 EXISTING LEACH PITS ' J I CONTRACTOR SHALL PUMP, r - / \106.26\ \ FILL WITH SAND & ABANDON. 106.39 x 105.48 x<% FUTILITY POLE . Ux x 107.72 S CB ' 101.39 yes 1-08 x 108.37 + i 1� ii x 106.97 // 105.33 �) EXISTING I 107.12 HOUSE(#193) x Ilk O.F.=109.f i t o i p 100.75 143.79 104.4 101.26 LQ DEC �PO� _01.36 t LQ P _ % �s• i � 104.6 � 102.46 10314�G ..: 3. -101.26. _: .101.19_ / \`/ -... .9 0�? • i 104.38 \ 03.60 102.34 PAVED , "c DRI V/EWAY.., �..... SHED 1 / +�, 101.54 �' 104.93 x &/ ff ;4 r 10 22 , „ �.,� > : io . 9.. S 89'03'26" E ,.---- ��' 1.19 W 102.4 100.68 ri W + rn 36' 402,22-- 101.53 i 99.11 100. _.--• ry`� - - _ -.-r-� 101.1 .55'.::". _:: .. , TP 0 O I 101.00 101.36 N PROP_ .A .� \ 7 ... .:..: 98.41 41 1-186 100.98x \ - 100.0 2x 996 .,o ,Q3/� 100.26 x �0 q -_ - - 98-----------/`- CV x 97.44 x 97.62 x 0 LOT 3 97.87 .- 96.64 40,003 S.F.f � MAP ID: 136-025 98,P�' S�� _---------'96-- /f 95.84 s- ✓.cri'.-`- O �� 195.33' J N 89'08'02" W BENCHMARK Yarmouth Health Department DRIVEWAY CORNER APP VED EL. =101.10 me Date TAKEN FROM CERTIFIED PLOT PLAN DATED 9/29/81. HOU E LOCATION PROPOSED SEPTIC SYSTEM UPGRADE PLAN o PETER T. �, McENTEE 193 SETUCKET ROAD, YARMOUTHPORT, MA v CIVIL No. 35109 Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 RE6IS1E�� Engineering by: SCALE DRAWN JOB. NO. E OWNER OF RECORD Engineering Works, Inc. 1 "=30' P.T.M. 159-17 93 SETUCKET ROAD U, RICHARD D & SUSAN L 112 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED 193 SE SHEET NO. y-� YARMOUTHPORT, MA 02675 (508) 477-5313 4/317 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:99.0 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D-BOX PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER PROPOSED S.A.S. SET TO 6" OF GRADE INSTALL RISER & COVER OVER ONE CHAMBER AND T.O.F.=109.3± SET TO 3' OF F.G. TO SERVE AS INSPECTION PORTS F.G. EL.=105.5± F.G. EL.=104.5± F.G. EL.=101.5%P F.G. EL.=101.0± L = 51' L = 13' ® S=1% (MIN.) ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2- 6" DOUBLE WASHED STONE " 10"1 6 as $ as (OR APPROVED FILTER FABRIC) 6138 BBB 14" Ba6a66a EXISTING 48" LIQUID aaaa6aa -3/4" TO 1-1/2" DOUBLE LEVELADD J . PROPOSED 4' 4.8' 4' WASHED STONE PROPOSE INV.=99.00 GAS BAFFLE INV.=102.45± D-BOX EFFECTIVE WIDTH = 12.8' EXISTING H-20 INV.=98.50 EXISTING SEPTIC TANK 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN H-10 RATED TOP CONC. ELEV.=99.3± Al NOTES: BREAKOUT ELEV.=99.0 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=98.50 ease ease INVERTS, PRIOR TO INSTALLATION. aaaa6 eases 2) D-BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM ELEV.=96.50 GRADE ON A MECHANICALLY COMPACTED SIX 4' 2 x 8.5'=17.0' 4' 4' OF NATURALLY OCCURRING INCH CRUSHED STONE BASE, AS SPECIFIED EFFECTIVE LENGTH = 25.0' PERVIOUS MATERIAL IN 310 CMR 15.221(2). 5' (MIN.) ABOVE G.W. 3) INSTALL INLET & OUTLET TEES AS REQUIRED. LEACHING SYSTEM SECTION 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE BOTTOM OF TP, EL.=90.0 AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. SEPTIC SYSTEM PROFILE SOIL LOG GENERAL NOTES: DATE: MARCH 29, 2017 SOIL EVALUATOR: PETER McENTEE SE#1542 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL WITNESS: AMY VON HONE RS HEALTH AGENT BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS ELEV. TP DEPTH OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 0 LOCAL RULES AND REGULATIONS. 101.0 A 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR LOAMY SAND 4/2 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE10YR 100.3 g" DESIGN ENGINEER. B 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING MED. SAND FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN IOYR 5/8 ENGINEER BEFORE CONSTRUCTION CONTINUES. 98.8 C 26" 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF MED. SAND HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 10YR 6/6 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 90.0 132" DIRECTED BY THE APPROVING AUTHORITIES. NO GROUNDWATER OBSERVED 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY PERC RATE <2 MIN/IN. ("C" HORIZON) THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3),IF 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND EXISTING NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. ti HOUSE#19.3 I� 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A TRENCH PERMIT FROM THE LOCAL MUNICIPALITY IN WHICH THE WORK IS BEING T.O.F.=109.3±1 PERFORMED. SPG d V ^ �°' N DESIGN CRITERIA D,, NUMBER OF BEDROOMS: 3 BEDROOMS SH SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN r-r DAILY FLOW: 330 GPD� I(PR071 DESIGN FLOW: 330 GPD `_GARBAGE GRINDER: NO-not allowed with design.A.S' LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF--25--- AT � S.A.S. LAYOUT .74 GPD/SF EXISTING SEPTIC TANK: 1000 GALLON CAPACITY PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D-BOXI: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED USE 2-500 GALLON LEACHING CHAMBERS IN SERIES 193 SETUCKET ROAD YARMOUTHPORT, MA SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES s SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 Engineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. Engineering Works, Inc. N.T.S. P.T.M. 159-17 TOTAL AREA: .............................................................. 471.2 S.F. DATE CHECKED SHEET NO. 12 West Crossfield Road, Forestdale, MA 02644 DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD (508) 477-5313 4/3/17 P.T.M. 2 of 2