Loading...
HomeMy WebLinkAboutEngineered Plan - 2017TOP OF FOUNDATION ELEV. = 100.00_-, (ASSUMED) 9.0t SLAB ELEV. = 93.0f 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB CONCRETE COVERS 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. 4" CAST IRON PIPE (OR EQUAL) MINIMUM CLEAN SAND INSPECTION PORT LOAM AND SEED 2" LAYER OF 1/8" TO 1/2" WASHED STONE 02,5 MAX. OR FILTER, FABRIC VENT n 2°N• NOT REQUIRED PITCH 1/4 PER FT. H LEVELERS TEE �� FLOW LINE r�???.5 '� ELEV. = 91.0' 10'. MIN. - 2,0„ ° ° ° \ ► NO WATER ENCOUNTERED AT _- ELEV. = N_ �'. 120 80.6 ELEV. = i"3.52 LEVEL ° L I j t ° ELEV.= _90.09_ ADD GAS ELEV. 8n.17 6" SUMP ELEV. E19.00 ° = '.I. �..f._,_..-_,_ _...._ ° ELEV. _ --- BAFFLE _ ------ '_x��'�` 17-3 'I 0i NUMBER OF BEDROOMS 3 ��: ,<$ I! ��e� ELEV. = z LIQPUID OUTLET aI �r 4 HIGH CAPACITY INFILTRATORS WITH \ GARBAGE DISPOSAL UNIT (EXISTING) tell - STONE IN AN z TOTAL ESTIMATED FLOW 4 FEET 14 INCHES TO BE WATER TESTED g ,S7 ( 110 GAL/GR./DAY X 3 IIM Q_ GAL./DAY 5 FEET 19 INCHES 1000 p 11 X 30 X 10 -TRENCH FORMATION 6 FEET 24 INCHESa'3 IF MORE THAN ONE OUTLET N REQUIRED SEPTIC TANK CAPACITY 'i_ GAL. a cFs`° 1 .A WELL N A ACTUAL SIZE OF SEPTIC TANK (EXIS MNG) 1s 4 GAL. 7 FEET 29 INCHES t`etm �°► �{ , EEti� (TO BE PLACED ON FIRM BASE) S01 A z`30 . ' ,J, 8 FEET 34 INCHES SE -PM Ve 1,11K �'' r '" iy Z ZONE SOIL CLASSIFICATION 3/4" TO 1 1/2" CLEAN t S L[:,� �q) INDEX DESIGN PERCOLATION RATE < __ MIN./IN. DOUBLE WASHED STONE / ADJUST EFFLUENT LOADING RATE Qom_ GAL./DAY/S.F. FREE OF FINES & SILT LEACHING AREA 4-74.3 SQ. FT. (1 i X35)-(47x2.X10/12) - s a :3 a_ i i `, � USGS PROBABLE WATER TABLE ELEV. _ - _ LEACHING CAPACITY (AREA X RATE) x',551 9- GAL.JDAY DI i OBSERVED WATER TABLE ( / / ) E 474.33 X 0.74 NOT TO SCALE BOTTOM OF TEST HOLE; ELEV. _ _fQ RESERVE LEACHING CAPACITY ^°' GAL./DAY N0TES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. Q_v) 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. K 97.3 135.10 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 98.4 �� 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. \ ) 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL 84.5 1 BE MORTARED IN PLACE. i 1 x 84.3 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH 3 4� I - OWNER / APPLICANT IS TO 1,01.0 'j " DEEDED OR ZONING. REGULATIONS. OVti t 01. `� x 88.4 a, OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. X7.9 1 ; \ �� 6, U nLITiES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR x 98.3 IS. TO CALL "DIG -SAFE" AT i-88fi-344-7233- AT LEAST 72 HOURS x 93.7 \ ` PRIOR TO COMMENCING WORK ON SITE. \ 87.1 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS .AS WELL AS 92J x a � *_ SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION C" 1S TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER \ LOT 71 \ \ eT6r�r�i\�.'r� IMMEDIATELY. X E 1 8. PARCEL IS IN FLOOD ZONE - 20, 250 .E S. _ - v,;_ f_ ►,,,r'., �, R 9. LOT IS'SHOA", :C"I ASSESSORS MAP _ i3 _ AS PARCEL 1€� } _ F - _11''dv "IEACH._F'T _1S-T�;-G.l- P!�pr',PED AND L"^CKFiLLED. - 1 ` I t3.✓ • f 97.4 .•�;1fl0,� ', �; , n , �O�U�GA-�0 a \.N. o / r .. CT x 99.3 �98 SEPTIC TANK �? 89.2 1 x 99. - t x 91. IT oV93.1 8 Yarm dealt Depa nt ` a�tls la rtltBae 1_ } 1Aq.0OVE 3.2 \ r u y ;/� � 98.9 s � 4�,:, � , � l 1- , e."� � ��QFP''d':.e CJ :1 _ 93.09_, q SOIL,r' 6ri x TCFr(2T- mTEST % f=REMCF-DatL C µ-; RAYES 90.8 D. ✓�C ' j BOX 1�E0. 9� b \ 4 s t i 94.0 2 " �;, w . a` :S ,VITA TIAs 00. i"� + rte. t t' CD 95.0 2�� �`% 1 .... 8' 99.4 x 1 • 92.9 {j .1.00' :J 11. 95.7 (7 �` ��' •� � j�,. DATE AGENT -' 98.9 I ¢L �"E DATE OF SOIL TEST MARCH 23 2017 SOIL TEST DONE BY Sw'EETSFR ENGINEERING WITNESSED BY _P �E�►AUO_ V 91 N L 1 ELEV.=--90.6 PERCOLATION RATE _ < 3 - MIN./INCH AT 46__ INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-6" Ap LOAMY SAND 10YR5/1 NO ROOTS 6-17" B LOAMY SAND 10YR6/6 ROOTS 17-52" Cl LOAMY .SAND 2.5Y7/4 52-120" C2 FINE SAND 2.5Y7/2 DATE MAR. 27, 2017 SCALE „ 20' REV. JOB NO. , A. - ��. CATCH BASIN 119 � ' � -. ... - �'ngaY.iKlncAK']T!'..tt3.Y+f!.faP..3+suRPlb+cT'N![A1TFA".F.iW�siA:9Ssle®9.TP . C.taaO�hM^ 15a.` .. .�:.'R'.vA�c3'Ii:Y-�dv�6'�. -+�P'�WBtttK!sfg..:�m,4r"90M1'd.em3'.MN.b#.1,H^�. x � �� E i �tt� '• GAS LINE G REV. c.o. '[SHEET 1 OF I F CLAN OUT LOCATION MAP . E CESSPOOL C.P. C.• SBPR0,1\7834-00 d)tq 834-SAS.DWO 0? 2017 S�iEETSER ENGINEERING