Loading...
HomeMy WebLinkAboutReview Checklist � �y� � �� �� TOWN OF YARMOUTtI � SEWAGE PLAN REVIEW CHECKLIST , Location: A.M.� Lot `� Zone of Contribution: In�'" Out Acreage �- � Commercial: Residential: Street: '.='�--. ; /'�1��7=,`��� Village: Floor Pl . -� #Bedrooms: ��;;-���C� O��': 1 � Installer: LQ Address: � Phone: --�` �- Phone: Builder: Engineer: Address: Phone: � Phone: ���dL� f j ��� ;� J^•� N/A YES NO l.Required#of copies received i,i 2.Date of soils exam and ercolation test not older than 2 years �--^ 3.4-5 ft of naturall occurrin ervious material,above water table �--� 4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.: �� 5. Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands L� 7. S tic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ' 9.Leaching minimum 100 ft from wetlands Var.: ' 10.Leachin minimum 150 ft from drinking welU25 ft irrigation well Var.: I 1 l.Tank/leaching minimum 10 ft from roperty line Var.: �.-- ; 12. S stem meets all other setback r uirements Var.: 13.Uses adjustment for maximum high groundwater Var.: �� 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: �,/ � 15. System not in to or subsoil(A,B horizons)or 5'removal �'" i 16.Pro osed contours are suitable � 17. S stem meets slo e re uirements-min. 1/8", '/a" referred � 18. System meets breakout re uirements PVC liner: Wall: / 19. S ecified tee sizes are proper, gas baffle on outlet tee �j � 20. Sewa e is under 10,000 d for parcel 21.No arbage dis osal j ' 22. S stem ade uatel sized for its intended use �' 23.Minimum 6"stone or compacted below tank and dbox �'' r 24.Manhole covers within 6"of grade, um chamber cover to ade t,�,/' 25.Ins ection port on plastic chambers/lea.ch field � 26.Electrical ermit for um chamber/S arate meter for du lexes � 27.Pump system-2"line,wee hole,check valve,tee in dbo�pum size � 28. Septic tank/pump chamber to be factory waterproofed � 29.Vent rovided if leaching below 3 feet, under driveway/ arking � 30.Buoyancy calculations for tank/pump chamber �,,.� ; 31.En ' eer to ins ect and cert' soils: wall: commerciaL• 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature i 33.H-20 loadin is subject to vehicular traffic, groundwater 34.Title V A lication and ermit fee, insta.11er si ature �/ 35.Foundation footing min. 2 feet above adjusted ground water for new house � 36.Deed Restriction r uired max. #bedrooms: max, flow: d � 37. Check area lots for groundwater/Label groundwater in Assessor's Ma E Plan reviewed by: ,�_ eiosio3 j