HomeMy WebLinkAbout47 Franklin St Ext Site Plan 2SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE TOP FOUND. EL. 13.5'** F 12.7' MINIMUM .75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2% SLOPE REQUIRED OVER SYSTEM 1 1.T1 J. 1 ,1, PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE mar -Ma kl1r.j 2'0 4 0SCH40 PVC : PIPES LEVEL 1ST 2' 2" DOUBLE -WASHED PEASTON OR GEOTEX11LE FABRIC 10" 1500 GAL H-10 14" 10.66' /� 10.7[{' TEE SEPTIC TANK TEE s ; o 0 0 0 0 0 0 0 0 o 0 o 0 0 0 0 0 0 o p00.0 a°o°o° 0°0°0°0°0°0°0 10.49 10.16' aaaaaaaaaaaaaaaaaaaaaaa0aaaaaaa 0 0 0 0 0 0 0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0°0 0°0°0°0°0°0°0° 0o0o0oO0000o °0000000°000000000000°0°0°0°0°0°0°0°0°0 0°0°0°0 0°0°0°0°0°0°0° GAS BAFFLE ::: °°���°°°°°° 0;0�0' i;°i; o�o�o°i;°o°i;°o°o�o�S°S°S°o°o°i; iaao°o° °o�o�o°o°0°0°8° 9.5' r: EQUAL 10.36' 10.19' 4" PVC SET AT .005'/' SLCPE 4' LIQ. LEVEL (ACME OR J� \-ON 6" DOUBLE WASHED 3/4" - 1 1/2" STONE 0°0°°0°0°0°0°0°0°00.000* °0°0°0°0°0°0°0°0°0°0°0°0°0°o WATER -TEST D'BOX FOR LEVELNESS , 10, 5 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (2-% SLOPE) (_L7. SLOPE) (1 %SLOPE) ' D' BOX 5' LEACHING USE ADJ. G -W 4.5' FOUNDATION 16' 13 SEPTIC TANK FAC I I 17 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **MIN ELEVATION TO PROVIDE GRAVITY FLOW AND HOLD MINIMUM 5' SEPARATION TO ADJUSTED GROUNDWATER LEGEN D - z7z7- tAiZ)iuNU wrvivum X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 TEST HOLE 2YYYi SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DAVID FLAHERTY, R.S., SE2755 WITNESS: PHIL RENAUD, YBoH DATE: 12/18/06 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 10.0' 0" 4 A LS 1OYR 5/4 B LS 35" 1OYR 5%8 7.08' 36" PERC C ®57" FMS 93" OBS WATER 2.25 94" 2.5Y 6/4 108" 1.0' 108" G -W ADJ. DATA: WELL: MIW 29 ZONE: BORDER A/B ADJ: 1.9'/2.8' (AVG. 2.3') 13-184 A LS 1OYR 5/4 B LS 1OYR 5/8 C FMS OBS WATER 2.5Y 6/4 ELEV. 10.0' 7.0' 10/17/13 D. GONSALVES, SE WITNESS: B. MURPHY & P. RENAUD ELEV. 0" 9.0' 22„ 2.17' 94" 1.0' 96" PROP. WATERLINE G -W ADJ. DATA (AH): WELL: MIW 29 ZONE: BORDER A/B L ADJ: 2.5'/3.7' (AVG. 3.1') 8 1.17' PROVIDE DRYWELLS FOR ALL ROOF RUN-OFF Scale:1 "= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPOSED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. WETLAND FLAGGED BY HAMLYN CONSULTING LOCUS MAP NOT TO SCALE ASSESSORS MAP 22 PARCEL 215.2 LOCUS IS CURRENTLY WITHIN FEMA FLOOD ZONE AE (EL 11) AS SHOWN ON COMMUNITY PANEL#25001CO588J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. BLDG COVERAGE: 25% MIN. FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' PROVIDE EROSION CONTROL BARRIER (HAY WATTLES) SITE IS NOT WITHIN APD AT ROAD RIGHT OF WAY IN AREA SHOWN (APPROX. t15') SYSTEM DESIGN: 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITHSPE FIC AI MED. SAND, M i15.2 � SPECIFICATIONS OF 310 CMR 15.255(3) X\ I N PROVIDE 90' OF 40 MIL N / LINER AT 5' OFF SAS IN AREA SHOWN. TOP AT ELEV. 10.7', BOTTOM AT EL. 6.7't GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD ( ) 2 = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: N/A BOTTOM 30 x 15 (.74) = 333 GPD TOTAL: 450 S.F. 333 GPD USE 30' x 15' x 0.5' DEEP LEACH FIELD WITH (3) 4" PERF. PVC IN DOUBLE WASHED STONE. SEE DETAIL , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF NAL DATE DANIEL A. OJALA, P.E., P.LIS. 47 FRANKLIN ST" EXT. WEST YARMOUTH PREPARED FOR ANTHONY DISIPIO DECEMBER 26, 2013 REV. 1/27/14 (NO FILL) REV. 2/3/14 (FILL) REV. 2/25/14 (WATTLE) REV. 2/29/16 (NAVD 88 DATUM) off 508-362-4541 I fax 508-362-9880 downcope.com down cape engineering, inc. civil engineers Ian d surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675