HomeMy WebLinkAboutBLD-17-5403Owner: Maplewood Senor Living One Gorham Island Westport, CT 06880 Architect: DMS design, Ilc Suite 339C, 100 Cummings Center Beverly, MA 0191 5 A ' k-,. Phone: 978-965-3470 Fax: 866-513-5573 No. a' Drawings: Cover Sheet A I First Floor Egress Plan - Phase I A2 First Floor Egress Plan Phase 2 A3 Second Floor Egress Plan A4 Enlarged First Floor Egress Plan - Phase I A5 Enlarged First Floor Egress Plan - Phase 2 _ I Issued: 23 February 2017 Y r « i° t= 3 , z' v.. r } ... ..... ..... „ sw , y e � t i r.1 w .., ..... ..t001- po ♦ . ... r ,:- r ..re: '`% ,; .:: •. \'..-:.:.x., :°r'TL*.. ._i '�.': a,:�; iy ,... .:. t. . .:. r %2' :b�»,, ka « x 1r ' v .' >"�, ):r. ,a '+: .. A..,.n "- n;: '�� .: Ya �.� .. Asn ..' ,. �,✓ _ i.[' � 0.0. Nl?.`�. w�_-a k1 ti -' ,.NS., e �,.y. • wr i�.. r ..... :.'. "' 'i: n ..., , �..: .,:.: �:: a r"i' i��i':' ,J?a Xx il,,. ... q..-.. .�, .,. ..,_: '!T..: ,, i,t �: :.as' ?:,_ ,.'.-. '.Asti ,7 _ a '::-.:•+x... g. ^>.;:;;.- x....,: ., '...:.: r. .,.: ?,- �'z:-- ;: ff a - r, Owner: Maplewood Senor Living One Gorham Island Westport, CT 06880 Architect: DMS design, Ilc Suite 339C, 100 Cummings Center Beverly, MA 0191 5 A ' k-,. Phone: 978-965-3470 Fax: 866-513-5573 No. a' Drawings: Cover Sheet A I First Floor Egress Plan - Phase I A2 First Floor Egress Plan Phase 2 A3 Second Floor Egress Plan A4 Enlarged First Floor Egress Plan - Phase I A5 Enlarged First Floor Egress Plan - Phase 2 _ I Issued: 23 February 2017 FIRST FLOOR SAFE ZONES ID PHASE AREA PERSONS REMARKS AVAILABLE' ALLOCATED CAPACITY 3 E 12 245 SF 49 32 G5% INCLUDES 8 APARTMENTS IN CARVER WING, 13 APARTMENTS IN EATON WING cnn F1 1 453 5F 90 G I G8% INCLUDES G APARTMENTS IN CARVER WING, MULTI-PURPOSE ROOM (40), CHAPEL (1 2) G 1 1 1715 SF 343 171 50% INCLUDES ALL 1 14 NON -MEMORY CARE APARTMENTS (171 PERSONS) a 1 *2 392 5F 78 78 100% INCLUDES 14 APARTMENTS IN WINSLOW WING, 14 APARTMENTS IN BRADFORD WING, ACTIVITY SPACES AND PUB/CAFE (3G) 168 O Gam' ° .-•.��pFORD "00 L LEGEND: F0771 SAFE ZONE X77 PATH TO ,•' SAFE ZONE NTS 0 NOTES: 149 ._ I . AVAILABLE SPACE CALCULATED AT I PERSON/5 SF (BASED ON STATE BUILDING CODE 156 0 14j ALLOWANCE FOR OCCUPANT LOAD ALLOWANCE, ASSEMBLY FUNCTION, STANDING SPACE). � 2. ALLOCATED USE CALCULATED AT 1.5 OCCUPANTS PER APARTMENT UNIT PLUS ANTICIPATED ��, 'y OCCUPANCY OF NOTED SPACES. LEGEND: O 3. CAPACITY FILLED WHEN OCCUPIED BY ALLOCATED PERSONS (ALLOCATED / AVAILABLE X 100). .+�iNs� p P O A� 4. ALLOCATION OF DINING SPACES F I F2 BASED ON USE BY ALL RESIDENTS. ° Ow -+ EXIT TO GRADE R j� / y �� PATH TO O 758 N G S 3. ,.' GRADE EXIT qj c 0 ° o 0 157 41 m a h HOPKI N5 LANE q /Y ASST h 160 3 OFFICE DIRECTOR O 0� ♦ 0� 1g9 O STAIR RETAIL CONFERENCE STORE ROOM I � ... � . I.MLL ROOM AdAINISTRATION DIRECTOR `♦ � (� nAleL A `-'. � ® FOUR V 1q -y_ d� ` �`L LpC .i pfee 'e �Q �L DIRECTOR ♦♦ , y LL ^� t'FS17gE.. 12 MENS EN , _ �. TOIL� X,TOILET ET !� CORRIDOR _ L Aft X -iiJ, O To Safe Zone (F1 ® LOBBY QRI MA S LOBBY • ' RM ELEV •/ \;/ 0 VESTIBULE ` U ELEV. *A .. -"M LOBBY11 �\ R MDIEATON -y,� ROOM NURSING WING Qom, NOT IN SCOPE CARVER- ' POOL®STAGE r' -. LlB4ARYT STORAGE CORRIDOR k HOPKINS LANE U O 17", 115 ' u 112 First Floor ress Dia ram w20 g g J \ > 114 w NTS � U Q 1 110 a<Ili 20 H 4 A R V E R W I N G EATON WI NG mrFy,QP w - ! ._ i F` ' I I LEGEND: N TENANT STORAGE I ! I C7 PHASE 1 109 o BmRAGE 106 i 104 i 102 STAIRie 162 i 163 D PHASE 2 TRASH Q � 1 1 , NU HOME NG_ - � FIRE STROBE ` -. FSTR FP (N t/ E I o Safe Zone (E) py,K E CORRIDOR I FSTR //�� SIR Fb H v� 1' . LL a I !® EXIT FP FIRE PULL LOUNGE „ 108 107 105 103 101 FEC FIRE EXTINGUISHER I 165 164 r7 CABINET I ( 1 , 1 rt - EXIT SIGN C A R V E R W I N G z w a w El t\ N a,u 166 10 EATON NURSING WING ------ _ NOT IN SCOPE _ CARVER %j cnn al .' z ' O Q O w First Floor Safe Zone Diagram NTS 0 NOTES: 149 ._ I . AVAILABLE SPACE CALCULATED AT I PERSON/5 SF (BASED ON STATE BUILDING CODE 156 0 14j ALLOWANCE FOR OCCUPANT LOAD ALLOWANCE, ASSEMBLY FUNCTION, STANDING SPACE). � 2. ALLOCATED USE CALCULATED AT 1.5 OCCUPANTS PER APARTMENT UNIT PLUS ANTICIPATED ��, 'y OCCUPANCY OF NOTED SPACES. LEGEND: O 3. CAPACITY FILLED WHEN OCCUPIED BY ALLOCATED PERSONS (ALLOCATED / AVAILABLE X 100). .+�iNs� p P O A� 4. ALLOCATION OF DINING SPACES F I F2 BASED ON USE BY ALL RESIDENTS. ° Ow -+ EXIT TO GRADE R j� / y �� PATH TO O 758 N G S 3. ,.' GRADE EXIT qj c 0 ° o 0 157 41 m a h HOPKI N5 LANE q /Y ASST h 160 3 OFFICE DIRECTOR O 0� ♦ 0� 1g9 O STAIR RETAIL CONFERENCE STORE ROOM I � ... � . I.MLL ROOM AdAINISTRATION DIRECTOR `♦ � (� nAleL A `-'. � ® FOUR V 1q -y_ d� ` �`L LpC .i pfee 'e �Q �L DIRECTOR ♦♦ , y LL ^� t'FS17gE.. 12 MENS EN , _ �. TOIL� X,TOILET ET !� CORRIDOR _ L Aft X -iiJ, O To Safe Zone (F1 ® LOBBY QRI MA S LOBBY • ' RM ELEV •/ \;/ 0 VESTIBULE ` U ELEV. *A .. -"M LOBBY11 �\ R MDIEATON -y,� ROOM NURSING WING Qom, NOT IN SCOPE CARVER- ' POOL®STAGE r' -. LlB4ARYT STORAGE CORRIDOR k HOPKINS LANE U O 17", 115 ' u 112 First Floor ress Dia ram w20 g g J \ > 114 w NTS � U Q 1 110 a<Ili 20 H 4 A R V E R W I N G EATON WI NG mrFy,QP w - ! ._ i F` ' I I LEGEND: N TENANT STORAGE I ! I C7 PHASE 1 109 o BmRAGE 106 i 104 i 102 STAIRie 162 i 163 D PHASE 2 TRASH Q � 1 1 , NU HOME NG_ - � FIRE STROBE ` -. FSTR FP (N t/ E I o Safe Zone (E) py,K E CORRIDOR I FSTR //�� SIR Fb H v� 1' . LL a I !® EXIT FP FIRE PULL LOUNGE „ 108 107 105 103 101 FEC FIRE EXTINGUISHER I 165 164 r7 CABINET I ( 1 , 1 rt - EXIT SIGN C A R V E R W I N G z w a V First Floor Egress Plan t\ N 1fi7 166 10 %j cnn al ce) N Mx!CIS O 0 v� A W '5 i5 Q z r- ;'.- C Lu 168 W A 1 1 1 1 I rn �o u IV 00 1 1 1 1 1 169 i O 174 172 170 ui 171 173 x rAUselsWeter1Dmpbox (DMS Design, LM)Wtaplewood-MayRower Place -579 Buds Wand Road, Yar naM, MAIM - Schenmtic Design\Fist V t\ N O r--4 f� %j a-+ ct al ce) N Mx!CIS .O �; v� A W '5 i5 ct r- ;'.- C +-jb u ~ M� U rnu,L" W A 1 1 1 1 I rn �o u IV 00 1 1 1 1 1 V t\ N O r--4 f� %j a-+ ct al ce) N Mx!CIS �; v� A W M M ct r- ;'.- C +-jb u ~ M� U rnu,L" CU b10 0 •� •� ��•++ 1 N % OS L U rn �o u IV 00 °aaar� 4° 1 %i cV t\ N O r--4 f� %j a-+ ct al ce) N Mx!CIS �; v� A A Floor Egress Plan.dwg 2/272017 FIRST FLOOR SAFE ZONES ID PHASE AREA PERSONS REMARKS AVAILABLE' ALLOCATED CAPACITY 3 E 12 245 SF 49 32 G5% INCLUDES 8 APARTMENTS IN CARVER WING, 13 APARTMENTS IN EATON WING z F2 2 304 SF GO G 1 100% INCLUDES G APARTMENTS IN CARVER WING, MULTI-PURPOSE ROOM (40), CHAPEL (1 2) GZ 2 852 5F 171 1 71 100% INCLUDES ALL 1 14 NON -MEMORY CARE APARTMENTS (171 PERSONS) [H] I t2 392 SF 78 78 100% INCLUDES 14 APARTMENTS IN WINSLOW WING, 14 APARTMENTS IN BRADFORD WING, ACTIVITY SPACES AND PUB/CAFE (3G) M qNL,Ln i °>s ti NOTES: X48 1. AVAILABLE SPACE CALCULATED AT I PERSON/5 SF (BASED ON STATE BUILDING CODE rS6 4 X47 Y- ALLOWANCE FOR OCCUPANT LOAD ALLOWANCE, ASSEMBLY FUNCTION, STANDING SPACE). y 2. ALLOCATED USE CALCULATED AT 1.5 OCCUPANTS PER APARTMENT UNIT PLUS ANTICIPATED O )5g 134 ti OCCUPANCY OF NOTED SPACES. s� s; O 3. CAPACITY FILLED WHEN OCCUPIED BY ALLOCATED PERSONS (ALLOCATED / AVAILABLE X 100). D F ° F°R q`� �� � 4. ALLOCATION OF DINING SPACES F I *- F2 BASED ON USE BY ALL RESIDENTS. N o Safe one 2 S 1 COaBY `��T 1 R�SS O� s �C9 IV ti y° �r°yah ��hHG • IS i 0• •' CORRIDOR MULTIPURPOSE ROOM MAIL ROOM H O PKI N5 LANE STAIRH I SI"CE I DIRECTOR E TORE FRE ADMINISTRATION fl DIRECTOR .amu �, :- �,• LOBBY ELEV t SOCIAL DIRECTOR F1 Y LEGEND: SAFE ZONE PATH TO ,•' SAFE ZONE ' � � E1 ; n ccv r...4 m AL L EATON NURSING WING - it T NOT IN SCOPE CARVER STORAGE ii,:::::!S=.-.RR11-R A z ai Lolluili 0 Pa uj First Floor Safe Zone Diagram $i NTS -► In V LBRARY n ccv r...4 m L 1 it T STORAGE ii,:::::!S=.-.RR11-R A -F-J En cN ai Lolluili 0 Pa r...I t04 .O $i cq l 1 W HOPKINS LANE 'S 1` COD a� eo v M qNL,Ln �80 Ln co A FLn x09 o aw O z 115 w J LL 192 First Floor gress Diagram W 0-/20 114 w NTS oC > U a - U 111 0 110 U -- C A R V E R W I N G N E A T O N W I N G (D o w LEGEND: .... _.. TENANTSTORAGE ! -- 4cz? D PHASE 1 109 cn 0106 STORAGE 104 1 102 162 i 163 PHASE 2 TRASH MO I I ' STAIR i6 I FSTR FIRE STROBE O Safe Zone (E) R 4 Y �� CORRIDOR E� RSiR t� ._. ., EXIT FP Q FIRE PULL LOUNGE 108 107 105 1103 f 101 FEC FIRE EXTINGUISHER I ( ! CABINET 165 164 EXIT SIGN C A R V E R W I N G Z lij First Floor Egress Plan 167 c 166 10 -o,. zca cn � O a z Lu 168 i 169 Z , ! O 174 172 --- -- � � a 170 w 171 173 x V n ccv r...4 m 4 N ,� A -F-J En cN ai Lolluili 0 Pa r...I t04 .O $i cq U) 1 W A 'S rwc� COD a� eo v M qNL,Ln �80 Ln co A FLn x09 o aw V n ccv r...4 m 4 N ,� A -F-J En cN ai Lolluili 0 Pa r...I t04 r..cd $i cq U) 1 W A a, co M rwc� COD eo v M qNL,Ln �80 Ln co A FLn x09 o aw w o � 0 N w co .� 4-J _� mm a w 40 w O ° T 0 � � U O134 CCS CCS 1 F -i n ccv cd 4 N ,� A -F-J En cN ai M Pa r...I t04 r..cd $i cq U) A A A2 Vl Y 0 U N O Q Vv U En p �� F LAI A /� • rN M ct ►F�"'ll W ^ kf) N kn U D1Mh -- C� rn � 00 _ JV V ; °O �GQaw 1 1 1 1 1 A3 Design\Second Floor Egress Plen.dwg 3(;?./2017 Y 0 U N U � Q Vv U En p �� F LAI A /� M ct ►F�"'ll W ^ kf) kn U D1Mh -- rn � 00 V ; °O �GQaw A3 Design\Second Floor Egress Plen.dwg 3(;?./2017 Y 0 r - N U � Q Vv <° En p �� F LAI A /� 0 ct w W ^ kf) A3 Design\Second Floor Egress Plen.dwg 3(;?./2017 r - C) o Q � M to LAI A /� A3 Design\Second Floor Egress Plen.dwg 3(;?./2017 WORK SIDE II 1 IjJ RE: Detail: Tern: SCALE: 1-1/2" =1'-0" First Floor Egress Plan (Phase 1) 3/32„ = 1.-0" Floor Egress Plen.dwg ?12712017 EXISTING FLOOR STRUCTURE RUNNER TRACK (TYPICAL) EXISTING FINISH CEILING EXISTING ACOUSTIC CEILING - GRID TO REMAIN IN PLACE, REMOVE TILES AS NEEDED FOR TEMPORARY PARTITION SINGLE LAYER 1/2" GYPSUM BOARD, FULL HEIGHT ON RESIDENT (NON -WORK) SIDE 3-5/8" METAL STUD @ 24" O.C. EXISTING FLOORING Work Partition i i I i i i I i i i WORK SIDE I RESID Detail: Terr. SCALE: 1-1/2" = V-0" EXISTING FINISH CEILING �— EXISTING ACOUSTIC CEILING SHALL REMAIN IN PLACE _G -MIL REINFORCED TRANSLUCENT, FIRE -RETARDANT POLYETHYLENE SHEETING (TYPICAL). SHEETING SHALL MEET OR EXCEED NFPA 701 TEST, METHOD 2 SPRING-LOADED TEMPORARY BARRIER SUPPORTS, 'ZIPWALU OR EQUIVALENT ,�EXISTWG FLOORING Dust Partition LEGEND: C� PHASE 1 (=°7 PHASE 2 cd . O FIRE STROBE FSTR '2 Q °,d E] FIRE PULL FEC FIRE EXTINGUISHER a-+ CABINET EXIT SIGN I~ ;_4 CTS +J 0 N cd . O I --q o N '2 Q °,d '5 iv 4-j od a-+ hh nn� • a A i�l cC Vpo. 0 � U o� AM M ct 2� M V ;_4 CTS +J 0 N cd O I --q o N '2 Q °,d ^ ,Fi w aj cd �r. a 4-j od a-+ hh nn� • a O 0 i�l cC Vpo. 0 � U o� AM M ct 2� M , p \i 4-1 V '" M m U rn T m Q� a 8,0 Ln rn ' 0 � VC"b W 00 °aaaw ti 12 s~ 0 ;_4 CTS +J 0 N cd O I --q o N i!� Q °,d ^ ,Fi w aj cd �r. a 4-j od a-+ O ^,^, a O 0 i�l cC Vpo. bO 10 P4 o� o CCS ct ;_4 CTS - 0 N cd O I --q o i!� H Op.� -"4 C� N A M co 2� �nAA No. 0038 EXISTING FLOOR STRUCTURE RUNNER TRACK (TYPICAL) 6 � F� �v Yti A. �3s EXISTING EXISTING FINISH CEILING FINISH CEILING EXISTING ACOUSTIC CEILING - EXISTING ACOUSTIC CEILING L NOTE: ! C GRID TO REMAIN IN PLACE, MAKE TEMPORARY R/0 REMOVE TILES AS NEEDED i SHALL REMAIN IN PLACE O R BARRIER SYSTEM i OR FOR TEMPORARY PARTITION 6 -MIL REINFORCED Sy TIGHT TO EXISTING ! TRANSLUCENT, FIRE-RETARDANTSINGLE LAYER I/2" GYPSUM SURFACES AT j POLYETHYLENE SHEETING RE51DENT ( ONARD, FULL EWOM 51DE AVOID DUIGHT ON ST MOVEMENT (TYPICAL). MOVEMENT INTO ! SHEETING SHALL MEET OR 3-5/8" METAL STUD @ 24" O.C. RESIDENTIAL AREAS EXCEED NFPA 701 TEST, T i METHOD 2 CO y p� SPRINGLOADED TEMPORARY 147 �� G 5� BARRIER SUPPORTS, 'ZIPWALL' OR EQUIVALENT i j I To O�� EXISTING FLOORING i EXISTING FLOORING O i O,Q WORK SIDE RESIDENTS SIDE WORK SIDE RESIDENTS SIDE DeFi'l: Tem ora Work Partition Detail: T ��.a em ora Dust Partition -1/2" _ �'-o" SCALE: 1-1/2" = 1'-0" �p F� 00 s9F9G 0, 1p�i j c0, b Op 9�Fy�0 GQ -1p y°G�ti G,y0 9cTi 2 G� EXIT ASST. OFFICE DIRECTOR p...e,. STAIR #1 RETAIL V cGti cp STR STORE CO ROOM CE % *� s Q� 9 O i c� �9��9 9�P� RMAIL OOM ADMINISTRATION DIRECTOR CHAPEL R • � b4 ,[ MAIL -) �^ U 110, F��` OXE V ` cif) #c' SOCIAL A 0 MENS MEN DIRECTOR r� FSR o a TOILET TOILET CCS CORRIDOR 2 v ? FP O 1` e- f, LOBBv y Ln M G LEV.7'EXIT> c � Lo !p F CH. RM ELEV. #1 . C CO ON G,yc� -nK VE TIBULE ELEV. LOBBY ��_ �j��00 MULTI-PURPOSE �{'� p ,� c ti ROOM I '�I r, f� P, far { STAGE FI' 2 STORAGE CORRIDOR LIBRARY i O�Fp FQ � I 0 T 115 'OA. 112 Oti \Qo 2 GO O 5�e' 9sy�tic � U N O OST O� V c� GOR?: �90 cz + P p., 3 G�Okl 5� O O F W O moi(;, First 4-4 C, )�3/32" Floor Egress Plan (Phase 2) �c " to g W �c�Fp ti a O 14 CCS CCS ca �Fc (LION ��Gti° s " LEGEND: PHASE 1 �G sTF� O PHASE 2 F O�F} FIRE STROBE FSTR FP FIRE PULL FEC FIRE EXTINGUISHER CABINET EXIT SIGN A5 (:'V lcwePrinrlflmMnr RllulS f�cinn 11 (:1W"Nw""N..Mw"flmunr Plarw57G Ri"4 IdnM Rnarl Vamwdh 11dAY1'i . CMamir rLeNnlGiM Floor Egress F7an.dwg 2/272017 II �-1 � N � CV O � `v � � M N � • p'� � . � t� co A A • � ai Floor Egress F7an.dwg 2/272017 II �-1 � N � CV � � `v � � M N � • p'� � U � t� co A A u c s an oa, %W/St al .0, t 9 6- Code Code Information Owner: Maplewood Senior Livincj DATE OF CONSTRUCTION: 1988 (EATON WING CONSTRUCTED 1998) byA: >; OCCUPANCY GROUP: R2, RESIDENTIAL OCCUPANCIES CONTAINING... MORE THAN Froaineecwn One Gorham Island ort, CT OG880 �1 °•awry TWO DWELLING UNITS WHERE THE OCCUPANTS ARE PRIMARILY West n R, PERMANENT IN NATURE". r KI E' YTnuo ar; CONSTRUCTION CLA551FICATION: IIB (CURRENT MASSACHUSETTS BUILDING CODE, 8TH EDITION `,• * ''" .. TYPE OF CONSTRUCTION IN WHICH THE BUILDING ELEMENTS Architect: vert `rr'•y�' ��«' LISTED IN TABLE GO I ARE OF ANY NONCOMBUSTIBLE •- � .�` � �� Cape Cod Bay North Eastham MATERIALS, EXCEPT AS PERMITTED IN SECTION G03 AND DMS de519n IIc Atlantic OceanOTHER AREAS OF THIS CODE".) AREA of 3ag`m '9each air 2C (MASSACHUSETTS BUILDING CODE, 4TH EDITION, 1988) woRK Suite 339C, 100 Cumming5 Center 4 areham-'.�+? •'c�'��','���h 8r. z MAOI 9 15 THE BUILDING HAS BEEN OBSERVED TO HAVE FULL SPRINKLER COVERAGE WITH A SYSTEM THAT B e ve r l Monumen[isearn �a L •+ „ COMPLIES WITH CODE SECTION 903.3.1.2 (NEPA TYPE 13K SPRINKLER SYSTEM) y gyp, D ARC iTI,�servaUon .. Z West Barrnta6k rirmarM Port-+�2 4 °�$' �t i i ✓ },fit,. X'�Drnnp„ Harwich 'i `�hatliam .�i r� iaresceat kMa st«,s Ines r�.•-a.+'•.�,:�.�,... Phone: 978-965-3470 I.Wffu� "�`"H'`h x .� ` Fax: 866-5 13-5573 Z00 z- OstevBe�" "' FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) 04 ry FROM TABLE GO I , MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION West frilmtnith, £ wr�Hp �} < , res Bay `�East6almdrths ,`. Fatrr�u V TYPE II BUILDING ELEMENT B i1� Ate@ Key Plan N.T.S. PRIMARY STRUCTURAL FRAME�G) p LOCATION '; � Yneynas�c( LOC ` F BEARING WALLS TOWN Off' YARMOUTH EXTERIOR (F,G) p REVIEWED FOR BUILDING AND ZONING CODE COMPLI- S ite Location Plan INTERIOR p ANCE, ERRORS OR ON,MISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT' +� NONBEARING WALLS AND PARTITIONS(e) 0 COMPLIANCE, 4 Y'L ,i< ,?m; •e ',.1 P Y, ( '3i ( '�^' Yf i't��. r*F_'Y 3a,,,t VW:-. 2 r ayig:. q { Y.•' M.hrAl`ti 1 { " ` .e- , '1 - yy►p_x. .r�1>,ww,.t-.v'.•1t. -f•�' j. w^.+r.i,,..-,,. i'.r :,°i�tr �x , .. ,:�i',4 . ofr t 4ah+.wy'p�,?,,.v:..'.=.r.:., ehr �'mC' �z,'.r-g.:'4;;',�.#s>•'s^Y,ci ,'�:Fry, -aa, ..w•+;`:�:-.b C ,yd t�4'?^`.�d:,r�C,•..,-"i<..k�*,�! ,.,,,�t`a d�a,..�:.�fi a ;r *a'�,. t'y+»':, 1-:�`_}Y �9:'^t�l4 ..r.t<.r;.,a..,-,�.-':5,.,r<.,,,"-y� DATE: i General Notes p xFLOOR CONSTRUCTION AND SECONDARY MEMBERSa*: BUILDING OFF Bu LDINGI WORK SHALL COMPLY WITH APPLICABLE PROV15IONS OF THE MASSACHUSETTS STATE BUILDING CODE, 780 CMR.LOCATION +' 0«) ROOF CONSTRUCTION AND SECONDARY r 2. BUILDING WILL REMAIN FULL Y OCCUPIED DURING ENTIRE CONSTRUCTION PERIOD. NKOs MEMBERS - ,r*tom :. ','�r' 4''.',.1 C,e• _t arG;. .�, 4•,tw<,�;,. . ,, ^�„�#.,,LL:. ��,;«,,.'v'd-.{ r v„ ��:.,:a*M ,+, 3 f�r,>. ,4s-``af�,Y , �de , e iai �,M �s . .� ..a. R-w� , ni :,-,;. ;�.��fiFr,.. � -; ° ;'�k �,�r°::;w..,� ,:�x.,�.��, � 3+ .�v.Y" ',, ��" 4�„ �`^+R74;'$•.:'a2'3.:na•. COOPERATE WITH OWNER DURING C ONSTRUCTION OPERATIONS TO MINIMIZE CONFLICTS FILE ■LE AV PY AND FACILITATE RESIDENT USAGE TO THE GREATEST EXTENT POSSIBLE. PERFORM WORK SO " x , ' A NOT TO INTERFERE WITH OWNERrS AND RESIDENTS DAY-TO-DAY OPERATIONS. C IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE ALLOWED WHERE A I —HOUR •,�_ ,.:, ,.,`. -�,. x ;, , ,,,r,.,+, :� ^ w. �. �, � ,, �,,f;,..,_ � % A: • . �.,,_ . �,-,.. >,.. � ,e. �, � .. �: 3. REFER TO AND COMPLY O Y WITH INFORMATION CONTAINED IN THE EVACUATION AND PHASING 4t .; # `r,,, T; , ` .;. OR LESS FIRE—RESISTANCE RATING IS REQUIRED. NOT APP I A �, ... � � �_ ,. , ,, I L C BLE TO THIS Drawings: " ' PLANS FOR THIS PROPERTY. REFER TO THE OWNER AND/OR ARCHITECT IN CASE OF `.:. Tt' • , .z ,, :,,, e: M WORK] REQUIRED CHANGES TO THESE PLANS. MAINTAIN EXISTING EXITS UNLESS OTHERWISE E NOT LESS THAN THE FIRE—RESISTANCE RATING REQUIRED BY OTHER Cover Sheet M ' w INDICATED. f , "r` ::, f' r� }; SECTIONS OF THIS CODE (OTHER SECTIONS DO NOT MODIFY �. "`.,_ s i w , REQUIREMENTS] ......'� ` '-" 4. REFER TO AND COORDINATE WORK IN THESE DRAWINGS WITH IN A I .0 1 Fir5t Floor Scope Plan W INTERIOR FINISH DRAWINGS y; .. }# , �C F NOT LESS THAN THE FIRE—RESISTANCE RATING BASED ON FIRE PREPARED BY THE ARCHITECTURAL TEAM, INC. REFER TO THE OWNER AND ARCHITECT IN SEPARATION DISTANCE ABLE .'':, ' ; . ,,.., .,�_, � r. � .� ..;, .. ,:�,', ,.,.. � ,>, ��<<.z . s-. { r' -�4 �aa'� � • Cf 602). [EXTERIOR WALL RATING NOT — ......,.. ... :.: ,.,?, , a -z^:r "'..:= t,x-.,: ,t.,,.g ,..r ,,a?.• .{,,.; r '. c.>„, .r::, ,,t >t� t ;;r a- >3.r:^ �z;"k� c CASE OF CONFLICT WITH REQUIREMENTS. APPLICABLE TO THIS WORK] Second Floor Scope Plan L'+f`"71+�� ^-'tr �F :.'',.�,p c* �i'A.1� r.:?- ''� 7-:,.. � ..�' ;,'.'n., *`�':' � ,:.;aw• a, � i:t f-. A^l� �.,����, tai �� „ �. �'"" , � ; .w , ., ,,,,,-�. �:� F- ,... . , � ,.�'. �+,. , , . '.y..�, � , ..�,. '�, • ,� ..:r .;.. .. G NOT LESS THAN THE FIRE RESISTANCE RATING As REFERENCED IN secrlON 5. MODIFY LOCATIONS OF SPRINKLER HEADS AS NECESSARY TO COMPLY WITH COVERAGE PER A— I .03 Enlarcjed First Floor Plan I of 2 ' "`' � ,r„ .- ��, ¢, : , »a � � �,2.,=�;,: -! ;` >• �, "'� 3r �-« `'� R �-.;:� 704. 10. (FIRE RATING OF EXTERIOR STRUCTURAL MEMBERS NOT N FPA 13 R. ' °'�•�/� ,�' �-r+�'—' x " �-±iG A.- a.�: ;,,,fir yx.�' a' � APPLICABLE TO THIS WORK] z y l �F., x r A .� A- I. 4 ed First Floor Plan 2 of 2 •A..,. " yf x' G. REFER TO OTHER NOTES ON INDIVIDUAL DRAWINGS. O Enlarg 'YrVIj,, Irq ;,` 4'a .S.Rt. s 1� } ,,�. F'� aXx• ,:r< ,moi >~: ::r Y 4aW '� s T" "i, ry — 1 A G.0 I Fin�5h and Door 5chedule5 ;.~�: "E' '^""�.- aN'1 f ��a .'`.n e .•AES �S,`� n t ''r2''�; ,: •d s »: £ 3r�`}�r-.<4s ._,k ;M B". -'� yi = `�a, :"h'.!�3 , ', 'i+"�. �r .,, •. . �- ,- :,'eV .,, ... a�,�A�Sj`��� �.,.::r y,, 'sa.r "fir k� a _ giNY ��'�" _" �1 "',eq ,k� is k' ',F�i :'a Jj, ��.w",<,. `..4,•`aY xc'1 y.��,+ .f S, 4gy,;�.,,��'!t i,.-.$''Yt'� A-. T, �r'm'f L��r:y. .N pf x, fs' ,yaf M -^i-: -i , I #� ># �: a 9i* a*'�' '9 y ""fffF.:�Fw.: �i i°' ,� e -s"' �. Ao x'„,�� •, �, a: 3 y f e � ', ° �'3 _ ». �w x � : _ Y S r ♦ � Mt t r J z <: 7W „,w.- �''�� � "�^ `. �,k, t �, t r�,,r*r e fix",, % �:� '* '^ y:: A� � <'.", 4 �' a { � .e '` �e,k.,l >k. � ..^� s p '«� 's � fs,t�,c} r � yc� �z,• �` "r r a- .a L .r `:" a a }. '� B'•: YN +, . J'7 iF `^ , �, ,. `' ,.,a .k, :v. 'w.:' t k' s� t°c' �.dtr`. s-„..--, r . , t 2 aFr r � •� '” +� MdR�� Ad r- '" ,•:' d � v r 3. ,�, ,t {, P ?s ,<-r� d :fir d s r,�„A'i: F_„y_- �: ;. ;.:. t .,,`d',, ">;` '��' "•�' +as,.,-,rk�..>r, ;:,,r,.,r..4 �.T'i•,; , `xc''4 144Se h Site Locus Plan 77f 2V7-,. 7iPt IMarc0 7 ..":�ft L r 7 q..." r z i d. k � J V..i:d G Sa' d a al �`..: z h 1 ,i:t :1+ :$ '^ ��.,.. a ,: 'r.'., x�i`-.,. "f .;� -e:.. Yk, :•,... g ., ... 1 ,?e, .. ..r, �•: } 4 4i*,�:'t - u _ --,'e: n, � i4 d. , .R , . .Ef� :, n T, i':.. ". `Y:. x , , ... .o- C tw N4 z ' AV L "F" dY{. '• I r• r: ,. , .,, :. :<:, '....:0.G, x:y F r•. -S , t n ' �J , 1' u c s an oa, %W/St al .0, t 9 6- Code Code Information Owner: Maplewood Senior Livincj DATE OF CONSTRUCTION: 1988 (EATON WING CONSTRUCTED 1998) byA: >; OCCUPANCY GROUP: R2, RESIDENTIAL OCCUPANCIES CONTAINING... MORE THAN Froaineecwn One Gorham Island ort, CT OG880 �1 °•awry TWO DWELLING UNITS WHERE THE OCCUPANTS ARE PRIMARILY West n R, PERMANENT IN NATURE". r KI E' YTnuo ar; CONSTRUCTION CLA551FICATION: IIB (CURRENT MASSACHUSETTS BUILDING CODE, 8TH EDITION `,• * ''" .. TYPE OF CONSTRUCTION IN WHICH THE BUILDING ELEMENTS Architect: vert `rr'•y�' ��«' LISTED IN TABLE GO I ARE OF ANY NONCOMBUSTIBLE •- � .�` � �� Cape Cod Bay North Eastham MATERIALS, EXCEPT AS PERMITTED IN SECTION G03 AND DMS de519n IIc Atlantic OceanOTHER AREAS OF THIS CODE".) AREA of 3ag`m '9each air 2C (MASSACHUSETTS BUILDING CODE, 4TH EDITION, 1988) woRK Suite 339C, 100 Cumming5 Center 4 areham-'.�+? •'c�'��','���h 8r. z MAOI 9 15 THE BUILDING HAS BEEN OBSERVED TO HAVE FULL SPRINKLER COVERAGE WITH A SYSTEM THAT B e ve r l Monumen[isearn �a L •+ „ COMPLIES WITH CODE SECTION 903.3.1.2 (NEPA TYPE 13K SPRINKLER SYSTEM) y gyp, D ARC iTI,�servaUon .. Z West Barrnta6k rirmarM Port-+�2 4 °�$' �t i i ✓ },fit,. X'�Drnnp„ Harwich 'i `�hatliam .�i r� iaresceat kMa st«,s Ines r�.•-a.+'•.�,:�.�,... Phone: 978-965-3470 I.Wffu� "�`"H'`h x .� ` Fax: 866-5 13-5573 Z00 z- OstevBe�" "' FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) 04 ry FROM TABLE GO I , MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION West frilmtnith, £ wr�Hp �} < , res Bay `�East6almdrths ,`. Fatrr�u V TYPE II BUILDING ELEMENT B i1� Ate@ Key Plan N.T.S. PRIMARY STRUCTURAL FRAME�G) p LOCATION '; � Yneynas�c( LOC ` F BEARING WALLS TOWN Off' YARMOUTH EXTERIOR (F,G) p REVIEWED FOR BUILDING AND ZONING CODE COMPLI- S ite Location Plan INTERIOR p ANCE, ERRORS OR ON,MISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT' +� NONBEARING WALLS AND PARTITIONS(e) 0 COMPLIANCE, 4 Y'L ,i< ,?m; •e ',.1 P Y, ( '3i ( '�^' Yf i't��. r*F_'Y 3a,,,t VW:-. 2 r ayig:. q { Y.•' M.hrAl`ti 1 { " ` .e- , '1 - yy►p_x. .r�1>,ww,.t-.v'.•1t. -f•�' j. w^.+r.i,,..-,,. i'.r :,°i�tr �x , .. ,:�i',4 . ofr t 4ah+.wy'p�,?,,.v:..'.=.r.:., ehr �'mC' �z,'.r-g.:'4;;',�.#s>•'s^Y,ci ,'�:Fry, -aa, ..w•+;`:�:-.b C ,yd t�4'?^`.�d:,r�C,•..,-"i<..k�*,�! ,.,,,�t`a d�a,..�:.�fi a ;r *a'�,. t'y+»':, 1-:�`_}Y �9:'^t�l4 ..r.t<.r;.,a..,-,�.-':5,.,r<.,,,"-y� DATE: i General Notes p xFLOOR CONSTRUCTION AND SECONDARY MEMBERSa*: BUILDING OFF Bu LDINGI WORK SHALL COMPLY WITH APPLICABLE PROV15IONS OF THE MASSACHUSETTS STATE BUILDING CODE, 780 CMR.LOCATION +' 0«) ROOF CONSTRUCTION AND SECONDARY r 2. BUILDING WILL REMAIN FULL Y OCCUPIED DURING ENTIRE CONSTRUCTION PERIOD. NKOs MEMBERS - ,r*tom :. ','�r' 4''.',.1 C,e• _t arG;. .�, 4•,tw<,�;,. . ,, ^�„�#.,,LL:. ��,;«,,.'v'd-.{ r v„ ��:.,:a*M ,+, 3 f�r,>. ,4s-``af�,Y , �de , e iai �,M �s . .� ..a. R-w� , ni :,-,;. ;�.��fiFr,.. � -; ° ;'�k �,�r°::;w..,� ,:�x.,�.��, � 3+ .�v.Y" ',, ��" 4�„ �`^+R74;'$•.:'a2'3.:na•. COOPERATE WITH OWNER DURING C ONSTRUCTION OPERATIONS TO MINIMIZE CONFLICTS FILE ■LE AV PY AND FACILITATE RESIDENT USAGE TO THE GREATEST EXTENT POSSIBLE. PERFORM WORK SO " x , ' A NOT TO INTERFERE WITH OWNERrS AND RESIDENTS DAY-TO-DAY OPERATIONS. C IN ALL OCCUPANCIES, HEAVY TIMBER SHALL BE ALLOWED WHERE A I —HOUR •,�_ ,.:, ,.,`. -�,. x ;, , ,,,r,.,+, :� ^ w. �. �, � ,, �,,f;,..,_ � % A: • . �.,,_ . �,-,.. >,.. � ,e. �, � .. �: 3. REFER TO AND COMPLY O Y WITH INFORMATION CONTAINED IN THE EVACUATION AND PHASING 4t .; # `r,,, T; , ` .;. OR LESS FIRE—RESISTANCE RATING IS REQUIRED. NOT APP I A �, ... � � �_ ,. , ,, I L C BLE TO THIS Drawings: " ' PLANS FOR THIS PROPERTY. REFER TO THE OWNER AND/OR ARCHITECT IN CASE OF `.:. Tt' • , .z ,, :,,, e: M WORK] REQUIRED CHANGES TO THESE PLANS. MAINTAIN EXISTING EXITS UNLESS OTHERWISE E NOT LESS THAN THE FIRE—RESISTANCE RATING REQUIRED BY OTHER Cover Sheet M ' w INDICATED. f , "r` ::, f' r� }; SECTIONS OF THIS CODE (OTHER SECTIONS DO NOT MODIFY �. "`.,_ s i w , REQUIREMENTS] ......'� ` '-" 4. REFER TO AND COORDINATE WORK IN THESE DRAWINGS WITH IN A I .0 1 Fir5t Floor Scope Plan W INTERIOR FINISH DRAWINGS y; .. }# , �C F NOT LESS THAN THE FIRE—RESISTANCE RATING BASED ON FIRE PREPARED BY THE ARCHITECTURAL TEAM, INC. REFER TO THE OWNER AND ARCHITECT IN SEPARATION DISTANCE ABLE .'':, ' ; . ,,.., .,�_, � r. � .� ..;, .. ,:�,', ,.,.. � ,>, ��<<.z . s-. { r' -�4 �aa'� � • Cf 602). [EXTERIOR WALL RATING NOT — ......,.. ... :.: ,.,?, , a -z^:r "'..:= t,x-.,: ,t.,,.g ,..r ,,a?.• .{,,.; r '. c.>„, .r::, ,,t >t� t ;;r a- >3.r:^ �z;"k� c CASE OF CONFLICT WITH REQUIREMENTS. APPLICABLE TO THIS WORK] Second Floor Scope Plan L'+f`"71+�� ^-'tr �F :.'',.�,p c* �i'A.1� r.:?- ''� 7-:,.. � ..�' ;,'.'n., *`�':' � ,:.;aw• a, � i:t f-. A^l� �.,����, tai �� „ �. �'"" , � ; .w , ., ,,,,,-�. �:� F- ,... . , � ,.�'. �+,. , , . '.y..�, � , ..�,. '�, • ,� ..:r .;.. .. G NOT LESS THAN THE FIRE RESISTANCE RATING As REFERENCED IN secrlON 5. MODIFY LOCATIONS OF SPRINKLER HEADS AS NECESSARY TO COMPLY WITH COVERAGE PER A— I .03 Enlarcjed First Floor Plan I of 2 ' "`' � ,r„ .- ��, ¢, : , »a � � �,2.,=�;,: -! ;` >• �, "'� 3r �-« `'� R �-.;:� 704. 10. (FIRE RATING OF EXTERIOR STRUCTURAL MEMBERS NOT N FPA 13 R. ' °'�•�/� ,�' �-r+�'—' x " �-±iG A.- a.�: ;,,,fir yx.�' a' � APPLICABLE TO THIS WORK] z y l �F., x r A .� A- I. 4 ed First Floor Plan 2 of 2 •A..,. " yf x' G. REFER TO OTHER NOTES ON INDIVIDUAL DRAWINGS. O Enlarg 'YrVIj,, Irq ;,` 4'a .S.Rt. s 1� } ,,�. F'� aXx• ,:r< ,moi >~: ::r Y 4aW '� s T" "i, ry — 1 A G.0 I Fin�5h and Door 5chedule5 ;.~�: "E' '^""�.- aN'1 f ��a .'`.n e .•AES �S,`� n t ''r2''�; ,: •d s »: £ 3r�`}�r-.<4s ._,k ;M B". -'� yi = `�a, :"h'.!�3 , ', 'i+"�. �r .,, •. . �- ,- :,'eV .,, ... a�,�A�Sj`��� �.,.::r y,, 'sa.r "fir k� a _ giNY ��'�" _" �1 "',eq ,k� is k' ',F�i :'a Jj, ��.w",<,. `..4,•`aY xc'1 y.��,+ .f S, 4gy,;�.,,��'!t i,.-.$''Yt'� A-. T, �r'm'f L��r:y. .N pf x, fs' ,yaf M -^i-: -i , I #� ># �: a 9i* a*'�' '9 y ""fffF.:�Fw.: �i i°' ,� e -s"' �. Ao x'„,�� •, �, a: 3 y f e � ', ° �'3 _ ». �w x � : _ Y S r ♦ � Mt t r J z <: 7W „,w.- �''�� � "�^ `. �,k, t �, t r�,,r*r e fix",, % �:� '* '^ y:: A� � <'.", 4 �' a { � .e '` �e,k.,l >k. � ..^� s p '«� 's � fs,t�,c} r � yc� �z,• �` "r r a- .a L .r `:" a a }. '� B'•: YN +, . J'7 iF `^ , �, ,. `' ,.,a .k, :v. 'w.:' t k' s� t°c' �.dtr`. s-„..--, r . , t 2 aFr r � •� '” +� MdR�� Ad r- '" ,•:' d � v r 3. ,�, ,t {, P ?s ,<-r� d :fir d s r,�„A'i: F_„y_- �: ;. ;.:. t .,,`d',, ">;` '��' "•�' +as,.,-,rk�..>r, ;:,,r,.,r..4 �.T'i•,; , `xc''4 144Se h Site Locus Plan 77f 2V7-,. 7iPt IMarc0 7 ..":�ft SCOPE NOTES, THIS DRAWING CENTRAL COMMON AREA ALTERATIONS - REFER TO DRAWINGS A-1 .03 * A-1.04 CENTRAL COMMON AREA = ALTERATIONS - �� REFER TO DRAWINGS A-1 .03 * A-1 .04 t u 10 CORRIDOR SCOPE NOTES I . CORRIDOR WORK INCLUDES: A. REMOVAL OF EXISTING ACOUSTIC CEILING TILES B. REMOVAL OF EXISTING CEILING GRID AND WALL ANGLES C. REMOVAL OF ALL MISCELLANEOUS HANGERS AND SUPPORTS D. REMOVAL OF EXISTING CEILING LIGHT FIXTURES E. INSTALLATION OF NEW CEILING GRID FOR 2x2 CEILING TILE F. INSTALLATION OF NEW 2x2 ACOUSTIC CEILING TILES G. REINSTALLATION OF CEILING LIGHT FIXTURES H. REMOVAL AND REPLACEMENT OF ALL EXISTING LEAN RAIL5 2. NEW CEILING GRID HEIGHT SHALL MATCH EXISTING 3. COORDINATE LOCATION OF SPRINKLER HEADS TO COMPLY WITH COVERAGE PER NEPA 13R. UNLESS OTHERWISE NOTED, 5PRINKER HEADS SHALL BE CENTERED IN NEW CEILING TILES 4. MAINTAIN ACCESS FOR RESIDENTS AT ALL TIMES \ ,/t First Floor Scope Plan 3/64" =1'-0" GENERAL NOTES I . IT IS THE INTENT OF THESE DRAWINGS TO GIVE THE CONTRACTOR AN IDEA OF THE EXISTING CONDITIONS AND TO INDICATE THE GENERAL SCOPE OF WORK TO BE PERFORMED. ANY DIMENSIONS SHOWN ARE TO BE CONSIDERED APPROXIMATE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL SIZES AND CONDITIONS FOR ANY A5-13UILT DISCREPANCIES WITH THESE DRAWINGS. 2. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY QUESTIONABLE STRUCTURAL CONDITIONS PRIOR TO AND DURING DEMOLITION WORK. 3. SPECIAL CARE IS TO BE TAKEN IN PRESERVING AREAS NOT INCLUDED IN THE SCOPE OF WORK AND SHALL REMAIN INTACT. 4. PROVIDE TEMPORARY SHORING AT ALL STRUCTURAL LOCATIONS WHERE WORK IS TO BE PERFORMED. NOTIFY THE ARCHITECT OF ANY QUESTIONABLE CONDITIONS. 5. ALL WORK SHALL BE PROTECTED FROM EXPOSURE TO THE WEATHER. G. ALL POSSIBLE PRECAUTIONS SHALL BE TAKEN TO ENSURE THE PROTECTION OF THE PUBLIC, WORKERS, AND PROPERTY FORM CONSTRUCTION HAZARDS. 7. DO NOT REMOVE ANY LOAD BEARING ELEMENTS INCLUDING, BUT NOT LIMITED TO, COLUMNS, BEAMS, POSTS, OR WALLS WITHOUT FIRST PROVIDING ADEQUATELY 51ZED TEMPORARY SUPPORT. 5. ALL INTERIOR DIMEN51ONS ARE FINISH DIMENSIONS TO THE FACE OF STUD. 9. ALL WOOD COMING IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 10. ALL PLUMBING, ELECTRICAL, AND HVAC WORK SHALL COMPLY WITH LOCAL AND STATE BUILDING CODES. 1 1 . ALL EXISTING CABINETS TO BE REFINISHED AND ALL COUNTERS TO BE REPLACED WITH GRANITE COUNTERTOPS. 12. COORDINATE SPRINKLER HEAD LOCATIONS WITH ANY NEW WORK OR LIGHT LOCATIONS. SPRINKLER HEAD SPACING SHALL COMPLY WITH NEPA 13 REQUIREMENTS. 13. REPLACE ALL EXISTING LEAN RAILS. U �^ rA UU � • i -a W V1 •�U rn LO Q� ~ N Irmo A 3� 4-J U civ U o 0 'D 00 4-J00 C\Z 0 0 10 rW, V W 0 0 i~ � O o0 O � b `v r~ cd 0 CCS 0 0 4-J as rn a CCS LO 0 ;= 0 o H � N � •O OM M W A U �^ rA UU � • i -a W V1 •�U rn LO Q� ~ N Irmo A 3� 4-J U civ U o 0 'D 00 4-J00 C\Z 0 0 10 rW, V W 0 0 i~ � O o0 O � b `v r~ cd 0 CCS 0 0 4-J as rn a CCS LO IA - 1.0 1 0 ;= 0 o H � N � OM M IA - 1.0 1 �— CORRIDOR ALTERATIONS — REPER TO CORRIDOR 5COPE NOTES, TH15 DRAWING C) CORRIDOR SCOPE NOTES I . CORRIDOR WORK INCLUDES: A. REMOVAL OF EXISTING ACOUSTIC CEILING TILES B. REMOVAL OF EXISTING CEILING GRID AND WALL ANGLES C. REMOVAL OF ALL MISCELLANEOUS HANGERS AND SUPPORTS D. REMOVAL OF EXISTING CEILING LIGHT FIXTURES E. INSTALLATION OF NEW CEILING GRID FOR 2x2 CEILING TILE F. INSTALLATION OF NEW 2x2 ACOUSTIC CEILING TILES G. REINSTALLATION OF CEILING LIGHT FIXTURES H. REMOVAL AND REPLACEMENT OF ALL EXISTING LEAN RAILS 2. NEW CEILING GRID HEIGHT SHALL MATCH EXISTING 3. COORDINATE LOCATION OF SPRINKLER HEADS TO COMPLY WITH COVERAGE PER NEPA 13R. UNLESS OTHERWISE NOTED, SPRINKER HEADS SHALL BE CENTERED IN NEW CEILING TILES 4. MAINTAIN ACCESS FOR RESIDENTS AT ALL TIMES V r--4 rmmmq n to .0 h� 2 Q+V N • TTPMM4 U) bJD Lo • U N A to o U N Vw °` n o0 bo 0ON 00I .4 O �o CN"o 00 x;00 o �x� W V 0 o o ro 3 b 0 U O 4 Q: a CCS � N rA � N U .o c A A 'S W crs A V r--4 rmmmq n to .0 h� 2 Q+V N • TTPMM4 U) bJD Lo • U N A to o U N Vw °` n o0 bo 0ON 00I .4 O �o CN"o 00 x;00 o �x� W V 0 o o ro 3 b 0 U O 4 Q: a CCS IA - 1. 02 1 � N rA � N U u v� c A A IA - 1. 02 1 O� <V O O O cd y U5 A A U � O� <V O O cd y U5 A A A- 1. 03 SUNSPACE GREENHOUSE 131 133 REMOVE NON-5TRUCTURAL COLUMNS AND WALLS w5m1m REPLACE EXISTING CABINETS, COUNTERTOP AND SINK ACTIVITY 130 VESTIBULE - 138 - REFINISH EXISTING CABINET - REFER TO NOTES REFINISH DINING DINIk- EXISTING CABINETS - ROOM 2 ROOM REFER TO NOTES _ 125-B 125A II f 120 ` ENS \\\ 1l LOBBY 2 PME04 O 126 REFINISH EXISTING SERVING COUNTER, PROVIDE NEW cfs +.A TOP - REFER TO DETAILS .0 d O ELEV. / MACH. PIANO .O `___—____- � o LOUNGE ROOM 107 07 113 BISTRO ' 12 127 \F REMOVE N � PERIMETER b ro \ 122 CROWN MOLDING �� IOU U �` U 8 113 I—, r VESTIBULE - 138 - REFINISH EXISTING CABINET - REFER TO NOTES REFINISH DINING DINIk- EXISTING CABINETS - ROOM 2 ROOM REFER TO NOTES _ 125-B 125A II f 120 ` ENS \\\ 1l PME04 O OOM♦ 118 LIBRARY cfs +.A / 105 .0 d O ELEV. / MACH. .O W � o R400M �/ / "' ♦ 122 / / ROOM 107 07 O V1 ' \F N � b ro \ 122 _ JANITOR 107A O �� IOU U �` U o0 o rnCo. RELOCATE EXISTING cz RELOCATE EXISTING DOOR AND FRAME 00 > DOOR AND TRANSOM - TO ROOM 103. REMOVE EXISTING FRAME, ai ami 00 p ayi 4 � O124 TO OPENING 1 22 \\ d, M a w -_ CL05E \\ \\ CHAPEL \\ 1 10 y TRANSOM OPENING, FINISH AND TRIM 124 D RELOCATE \\ .� EXISTING DOOR OPENING TO MATCH ADJACENT EXISTING DOOR AND FRAME TO OPENING 101 B, - <� — RELOCATE EXISTING DRAIN, CL05E EXISTING -n IN WALL TO ACCOMODATE OPENING COORIDOR NEW DOOR ' 120 11 Q 11 q MULTIPURPOSE o�yL��/tij ROOM r� c" 111 f11 PAI CL05E EX15TING OPENING wwj 117 CORRIDOR 115 119 PRIVATE MENS ROOM 117 GENERAL NOTES I . IT 15 THE INTENT OF THESE DRAWINGS TO GIVE THE CONTRACTOR AN IDEA OF THE EXISTING CONDITIONS AND TO INDICATE THE GENERAL SCOPE OF WORK TO BE PERFORMED. ANY DIMENSIONS SHOWN ARE TO BE CONSIDERED APPROXIMATE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL SIZES AND CONDITIONS FOR ANY A5-15UILT DISCREPANCIES WITH THESE DRAWINGS. 2. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY QUESTIONABLE STRUCTURAL CONDITIONS PRIOR TO AND DURING DEMOLITION WORK. 3. SPECIAL CARE 15 TO BE TAKEN IN PRESERVING AREAS NOT INCLUDED IN THE SCOPE OF WORK AND SHALL REMAIN INTACT. 4. PROVIDE TEMPORARY SHORING AT ALL STRUCTURAL LOCATIONS WHERE WORK 15 TO BE PERFORMED. NOTIFY THE ARCHITECT OF ANY QUESTIONABLE CONDITIONS. 5. ALL WORK SHALL BE PROTECTED FROM EXPOSURE TO THE WEATHER. G. ALL POSSIBLE PRECAUTIONS SHALL BE TAKEN TO ENSURE THE PROTECTION OF THE PUBLIC, WORKERS, AND PROPERTY FORM CONSTRUCTION HAZARDS. 7. DO NOT REMOVE ANY LOAD BEARING ELEMENTS INCLUDING, BUT NOT LIMITED TO, COLUMNS, BEAMS, POSTS, OR WALLS WITHOUT FIRST PROVIDING ADEQUATELY SIZED TEMPORARY SUPPORT. 5. ALL INTERIOR DIMENSIONS ARE FINISH DIMEN51ON5 TO THE FACE OF STUD. 0. ALL WOOD COMING IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 10. ALL PLUMBING, ELECTRICAL, AND HVAC WORK SHALL COMPLY WITH LOCAL AND STATE BUILDING CODES. 1 1 . ALL EXISTING CABINET5 TO BE REFINISHED AND ALL COUNTERS TO BE REPLACED WITH GRANITE COUNTERTOPS. 12. COORDINATE SPRINKLER HEAD LOCATIONS WITH ANY NEW WORK OR LIGHT LOCATIONS. SPRINKLER HEAD SPACING SHALL COMPLY WITH NFPA 13 REQUIREMENTS. 13. REPLACE ALL EXISTING LEAN RAILS. WALL LEGEND WALLS TO BE REMOVED NEW WALLS EXISTING WALLS TO REMAIN ® ® LIMIT OF WORK LINE C) PME04 O �W V n cfs +.A � Lift .0 d Q� .O W � o � G O p O V1 bo N � b ro O �� IOU U �` U o0 o rnCo. 'r-4 cz C) PME04 O �W V n cfs +.A � Lift .0 d Q� r W � o � G O p O V1 bo N � b ro O �� IOU U �` U o0 o rnCo. 'r-4 cz 00 ai ami 00 p ayi 4 � M a w IA - 1.041 O �W V cfs +.A '° c d r W � o � G O p O s~ � O cd � b ro O Oa 4-J m rn IA - 1.041 O r• cfs +.A '° c d r A A IA - 1.041 DOOR SCHEDULE FIRST FLOOR DOOR NO. ROOM DOOR j FRAME HDW SET FIRE RTG. REMARKS FROM TO SIZE MAT'L ELEV. GLASS MAT'L ELEV. HEAD JAMB SILL 100 VESTIBULE EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- -- EXISTING SLIDING DOOR I OOA LOBBY 1 VE5TIBUI F EXISTING AUGL -- -- AL -- -- -- -- -- -- ACT 101 LOBBY I VESTIBULE EXISTING AUGL -- -- AL -- -- -- -- -- -- EXISTING SLIDING DOOR IOIA CARVER WING LOBBY I EXISTING HM -- -- PM -- -- -- -- -- 0 MIN DOOR AT FIRE SEPARATION WALL 101 B JANITOR LOBBY I EXISTING HM -- -- PM -- -- -- -- -- -- RELOCATED DOOR AND FRAME 101C LOBBY I STAIR C EXISTING HM -- -- PM PT PT 107 ELEV. MACHINE ROOM 30 MIN DOOR AT FIRE -RATED STAIR WAIL IOID STAIR C EXTERIOR EXISTING 5CW -- -- WD -- -- -- -- -- -- PT 102A CLOSET OFFICE EX15TING SCW -- -- WD -- -- -- -- -- -- PT 102B CLOSET OFFICE EXISTING SCW -- -- WD -- -- -- -- -- -- EXIST. 103 LOBBY I MARKETING EXISTING 5CW -- -- WD -- -- -- -- -- -- RELOCATED DOOR, FRAME AND TRANSOM 104 OFFICE SOCIAL DIRECTOR EXISTING SCW -- -- WD -- -- -- -- -- -- 1 12 105 LOBBY I LIBRARY EXISTING SCW -- -- WD -- -- -- -- -- -- CPT 105 OFFICE DIRECTOR EXISTING 5CW -- -- WD -- -- -- -- -- -- PT 107 El FV. MACH. RM. JANITOR EXISTING HM -- -- PM -- -- -- -- -- -- PT 108 OFFICE A5515T. DIRECTOR EXISTING SCW -- -- WD -- -- -- -- -- -- ACT 109 LOBBY I STORAGE EXISTING SCW -- -- WD -- -- -- -- -- -- PT 110 OFFICE OFFICE EX15TING 5CW -- -- WD -- -- -- -- -- -- I I I A MULTI-PURP. RM. LOBBY I EXISTING HM -- -- PM -- -- -- -- -- -- RELOCATED DOOR AND FRAME 1 1 1 B MULTI-PURP. R.M. CORRIDOR EXISTING SCW -- -- " WD -- -- -- -- -- -- W -PTD I I I C MULTI-PURP. RM. STORAGE EXISTING SCW -- -- WD -- -- -- - -- -- PT I I I D MULTI-PURP. RM. CORRIDOR EXISTING SCW -- -- WD -- -- -- -- -- -- PT I I I E CORRIDOR STORAGE EXISTING SCW -- -- CPT WD -- -- -- -- -- -- PT I I I F MULTI-PURP. RM. STORAGE EXISTING 5CW -- -- PT WD -- -- -- -- -- -- 125D 1 1 2 OFFICE ED. OFFICE ROOM EXISTING SCW -- - ACT WD -- -- -- -- -- -- W -PTD 112A LOBBY I ED. OFFICE ROOM EXISTING 5CW -- -- PT WD -- -- -- -- -- -- RELOCATED DOOR, FRAME AND TRANSOM 113 LOUNGE VESTIBULE EXISTING AUGL -- -- CORRIDOR AL -- -- - -- -- ACT EXIST. 113A VESTIBULE EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- PT PT 114 LOBBY I CONFERENCE RM. EXISTING 5CW -- -- WD -- -- -- -- -- -- 131 I I G LOBBY I WOMEN'S ROOM EXISTING SCW -- -- WD -- -- -- -- -- STORE CPT 117 CORRIDOR MEN'S ROOM EXISTING SCW -- -- PT WD -- -- -- -- -- PT PT 118 LOBBY I MEN'S ROOM EXISTING SCW -- -- 134 WD -- -- -- -- -- PT ACT 119 CORRIDOR WOMEN'S ROOM EXISTING SCW -- -- W -PTD WD -- -- -- -- -- PT PT 122 CORRIDOR POSTAL ROOM EX15TING 5CW -- -- WD -- -- -- -- -- -- RELOCATED DOOR AND FRAME 123 PRIVATE DINING EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- -- CPT 124 CORRIDOR CHAPEL EXISTING SCW -- -- WD -- -- -- -- -- -- 125A KITCHEN DINING ROOM I EXISTING SCW -- -- WD -- -- -- -- -- -- 1258 DINING ROOM 2 EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- 12G LOBBY 2 EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- -- 127 CAFE SNACK EXISTING SCW -- -- WD -- -- -- -- -- 128 CORRIDOR CORRIDOR EXISTING HM -- -- PM -- -- -- -- -- O MIN EXISTING DOOR AT FIRE WALL 125A CAFE EXTERIOR EXISTING AUGL -- -- AL` -- -- -- -- -- -- 12813 CAFE EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- -- 128C CAFE EXTERIOR EXISTING AUGL -- -- AL -- -- -- -- -- -- 1281) CAFE EXTERIOR EX15TING AUGL -- -- AL -- -- -- -- -- -- 130 CORRIDOR ACTIVITY EXISTING 5CW -- -- WD -- -- -- -- -- - 130A CLOSET ACTIVITY EXISTING SCW -- -- WD -- -- -- -- -- 132 CORRIDOR STORE EXISTING SCW -- -- WD -- -- -- -- -- -- 133 GREENHOUSE SUNSPACE EXISTING AUGL -- -- AL -- -- -- -- -- -- 133A STORAGE GREENHOUSE EXISTING SCW -- --' WD -- -- -- -- -- -- 134 CORRIDOR OFFICE EXISTING 5CW -- -- WD -- -- -- -- -- -- 135 CORRIDOR SALON EXISTING SCW -- -- WD -- -- -- -- -- -- 135A CLOSET SALON EXISTING SCW -- --i WD -- -- -- -- -- -- 137 SUNSPACE SALON WAITING EXISTING SCW -- --j WD -- -- -- -- -- -- EX WD EXISTING WOOD HM -G HOLLOW METAL, GALVANIZED PM PRESSED METAL PM -G PRESSED METAL, GALVANIZED 5CW SOLID -CORE WOOD TEMP. TEMPERED TGL TEMPERED GLASS FINISH SCHEDULE FIRST FLOOR SPACE NO. SPACE DESCRIPTION O � m WALL CEILING O o Lu O � o� REMARKS N E S W MAT. HEIGHT 100 ENTRY VESTIBULE CPT W -PTD PT PT PT PT ACT EXIST. PT PT • 101 LOBBY I VARIES W -PTD PT PT PT PT VARIES EXIST.PT PT t 102 RECEPTION CPT W -PTD PT PT PT PT ACT EXIST. PT PT REWORK/REFIN15H DESK CABINETS 103 MARKETING OFFICE CPT W -PTD PT PT PT PT ACT EXIST. PT PT 104 SOCIAL DIRECTOR CPT W -PTD PT PT PT PT ACT EXIST. PT PT 105 LIBRARY CPT W -PTD PT PT PT PT ACT EXIST. PT PT IOG DIRECTOR CPT W -PTD PT PT PT PT ACT EXIST. PT PT 107 ELEV. MACHINE ROOM EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. -- -- 107A JANITOR CONC V5A5E PT PT PT PT ACT EXIST. PT PT 108 ASSISTANT DIRECTOR CPT W -PTD PT PT PT PT ACT EXIST. PT PT 109 ELEVATOR LOBBY CPT W -PTD PT PT PT PT ACT EXIST. PT PT 110 OFFICE CPT W -PTD PT PT PT PT ACT EXIST. PT PT I I I MULTI-PURPOSE ROOM CPT W -PTD PT PT PT PT ACT EXIST. PT PT 1 12 ED. OFFICE ROOM CPT W -PTD PT PT PT PT ACT EXIST. PT PT 1 13 PIANO LOUNGE CPT W -PTD PT PT PT PT ACT EXIST. PT PT 1 14 CONFERENCE ROOM CPT W -PTD PT PT PT PT ACT EXIST. PT PT 115 CORRIDOR CPT W -PTD PT PT PT PT ACT EXIST. PT PT I I G WOMEN'S ROOM CT CT PT PT PT PT ACT EXIST. PT PT 1 1 7 MEN'S ROOM CT CT PT PT PT PT ACT EXIST. PT PT 1 18 MEN'S ROOM CT CT PT PT PT PT ACT EXIST. PT PT 1 19 WOMEN'S ROOM CT CT PT PT PT PT ACT EXIST. PT PT 120 MAIL ROOM CPT W -PTD PT PT PT PT ACT EXIST. PT PT 121 DINING RECEPTION CPT W -PTD PT PT PT PT ACT EXIST. PT PT 122 POSTAL ROOM CPT W -PTD PT PT PT PT ACT EXIST. PT PT 123 PRIVATE DINING VARIES W -PTD PT PT PT PT ACT EXIST. PT PT NEW COUNTERTOPS, REFINISH CABINETS 124 CHAPEL CPT W -PTD PT PT PT PT ACT EXIST. PT PT 125A DINING ROOM I VARIES W -PTD PT PT PT PT ACT EXIST. PT PT NEW COUNTERTOPS, REFINISH CABINETS 125D DINING ROOM 2 VARIES W -PTD PT PT PT PT ACT EXIST, PT PT NEW COUNTERTOPS, REFINISH CABINETS 12G LOBBY 2 CPT W -PTD PT PT PT PT ACT EXIST. PT PT 127 BISTRO PLAN q W -PTD PT PT PT PT ACT EXIST. PT PT NEW COUNTERTOPS, REFINISH CABINETS 128 CORRIDOR CPT W -PTD PT PT PT PT ACT EXIST. PT PT 123 LOUNGE PLAN W -PTD PT PT PT PT ACT EXIST. PT PT NEW COUNTER* COUNTERTOP 130 ACTIVITY VPLANK W -PTD PT PT PT PT ACT EXIST. PT PT 131 SUNSPACE -- W-FTD PT PT PT PT ACT EXIST. PT PT 132 STORE CPT W -PTD PT PT PT PT ACT EXIST. PT PT 133 GREENHOUSE -- W -PTD PT PT PT PT ACT EXIST. PT PT 134 OFFICE CPT W -PTD PT PT PT PT ACT EXIST. PT PT 135 BEAUTY SALON CPT W -PTD PT PT PT PT ACT EXIST. PT PT 13G CAFE PLAN W -PTD PT PT PT PT ACT EXIST. PT PT 137 SALON WAITING PLAN W -PTD PT PT PT PT ACT EXIST. PT PT 138 VESTIBULE CPT W -PTD PT PT PT I PT ACT EXIST. PT PT KEY ACT ACOUSTIC CEILING TILE CONC CONCRETE CPT CARPET CT CERAMIC TILE EXIST. EXISTING PT PAINT VARIES SEE FINISH PLANS VBASE VINYL BASE VPLANK VINYL PLANK W -PTD WOOD, PAINTED WD WOOD NOTE: REFER TO INTERIOR FINISH DRAWINGS BY THE ARCHITECTURAL TEAM, INC. FOR SPECIFIC FINISH MATERIALS, COLORS, ETC. Tib V 0cd n C/) H �..j U N U Qjj .O 0 rPO4� M V1 • � aJ � b b cu Lr--� N O t � � n 4.j ct � tr L M N a .�.J U U 0 ., 'O o0 Lo WD 00 U V 0cd n C/) H �..j U N U Qjj • 0 rPO4� M V1 o � aJ � b b Lr--� N O t � � n 4.j ct � tr L M N a .�.J U U 0 ., 'O o0 Lo WD 00 Oro� C\\0 U �00 o>o as a I� V 0cd o H �..j N U rn /. z 0 �+ M A o � aJ � b b Lr--� O t U 0 4.j ct a Lo 0cd o H �..j N U rn /. z �+ M A