Loading...
HomeMy WebLinkAboutEngineered Plan - 2004TDP FNDN, AT EL, 23.4' SYSTEM PROFILE + `- ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6' OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM A - - G�A RUN PIPE LEVEL 2' DOUBLE WASHED PEASTONE\ cy %\ EXISTING 1000 ��, w / FOR FIRST 2' GALLON SEPTIC TANK (H- 10 ) 1 GAS S ± ITEE - 1 RE -USE BAFFLE25S 22.08' 22. +s P � 0 2� _ _ M. (n�11 _ 4' 6' CRUSHED STONE OR MECHANICAL i V 1 DE 1iH ❑F FLOW - - - A: COMPACTION. rj�iY{TEE SIZES CgMPACTION. (15.221 [2]) co-- eyl �I" I " INLET DEPTH = 10" "o tet'' 0.58' t 4v � _ 14" 3/4' TO 1 1/2" DOUBLE WASHED '> STONE," OUTLET DEPTH - ��C ;A16 FOUNDATION - EXIST SEPTIC TA --- 17' PUMP NK 92 D' BOX 2' _EACHING F-1 CHAMBER -ACILITY ALARM AND CONTROL PANELTO BE INSTALLED INSIDE ` BUILDING. ALARM TO BE ON INV. 1N 17.75' SEPARATE CIRCUIT FROM PUMP 1000 GAL. H-10 S/ U 2' PRESSURE PIPE TO D'BUX ALARM ON 700 GAL.+ SLOPE TO DRAIN BACK TO PC . FLOAT SWITCH RESERVE ,WEEP HOLE SETTINGS, PUMP ON CHECK VALVE 4' WORKING RANGE 8' ZOELLER 'WASTEMATE' 4' SUBMER$ MODEL M282 1/2 HP PUMP PUMP OFF 8• SYSTE .,QUAL) / 64 4 6' CRUSHED STONE OR COMPACTION PUMP CHAMBER , (NOT TO SCALE) / +21.24 G /20.14 C> / 61 X0.16 20.29 \ 12" SPRI / 0153 W 4-2V3 --1,2i 7 / \\� OH TEL 420.64 -I-2137 ( * 2� o N G 1 �-I- nH ELECTRIC �` BENCH MARK - CTR OF C. BASIN ELEVATION - 20.6' /2S 01-312 12" 14" UCE V TH1 v 4 23 �, _'2.23 / 38 C / / // 2 ,00 22.14 T2 5 0 6 } 'AVED W ...99 DRIV .49 W� X2.05 22.65+ 22.4 G - 39 3.41 3.17 +22.53 CONC. .44 PATIO 23.21 EXIST DWELLING TF = 23.4' EXIST. 1000 GAL. SEPTIC TANK (RE -USE) LOT 56 20,000± SQ. FT. +23.2 23.25' 0.75' MIN 22.5' I 3 21_� 14.5' 4 f 17. 5 t TE ST HOLE LOGS ENGINEER, ARNE H. OJALA, PE WITNESS AMY VON HONE, RS DATE: NOV. 19, 2001 PERC. RATE = T_ < 2 MIN/INCH CLASS I SOILS P# FA'LED '°ELEV o' A _ L.S 6" 10YR 5/3 B SL 20" 1CYR 5/4 FAILED ELEV A LS 10" 10YR 3/3 �3 LS 24" 2.5Y 5/6 0' Q 23.0' A LS 3" 10YR 4/3 B LS 9 10YR 5/3 22.25' ASSESSORS MAP 141 PARCEL 33 WELL: SDW 252 ZONE: A 4 ADJ. WATER A" EL. 17,0' C1 C' Ci ADJ: 2.0' SL FS 32., MS 87" 2.5Y 6/3 48" 2 5Y 5/6 r C2 66" 10YR 5�8 (:2 `MILT LOAM C2 17.5' VARIANCE REQUESTED UNDER MAX. FEASIBLE SILT LOAM i 142•• 2.5Y 5/2 SL COMPLIANCE '15.405 (1): :68" 2.5ti 6/3 1 2.5Y 6/3 is REDUCTION IN SEPARATION TO ADJUSTED GROUNDWATER, 5' TO 4.5' _- - -- 3 �' C 3 72.. 17.0' t�LU `CLAY EI_UE CLAY C3 1 g0" 52.. 95' B� Yl!dTE 15.0' 120" MS 1 .0' +20.67 I � BLOCKS AS NECESSAR` NOTES:_ `SOQ, 1. DATUM IS APPROXIMATED FROM QUAD SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED > Z, MUNICIPAL WATER IS EXISTING +22.34 DESIGN 3 FLOW: 3• BEDROOMS ( 110 GPD) 30 = 332 GPD 3. MINIMUM PIPE PITCH TO BE 1/Et` PER F'pDT, USE A GPD DESIGN FLOW 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHD H-10 2� SEPTIC TANK: 330 GPD ( 2 ) = 660 , S. PIPE JOINTS TO BE MADE WATERTIGHT, +22'44 USE A 1000 GALLON SEPTIC TANK (EXIST.) 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, LEACHING:7. ENVIRONMENTAL CODE TITLE V. SIDES: -. (36.2 + 10.83-_(.58) (.74) 40 4 THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. BOTTOM. 36.25 x 10.83 74 = (• ) 290.5 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. -I z3'll '� TOTAL, --- 447 S, F. 330 9 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION TH3 6,0, �3.sa` USE (6) STANDARD INFILTRATORS WITH 4' STONE AT OBTAINED FROM BOARD OF HEALTH. `3's6 SIDES AND 2.5'--A 'r NDS 10. PUMP & REMOVE FAILED LEACH PIT 1 11. ELECTRICAL PERMIT REQUIRED LEGEND TITLE 5 j�� PROPOSED SPOT ELEVATION OF 36 HOMER'S DOCK ROA 100x0 EXISTING SPOT ELEVATION 100 CG 119- 0 IN THE TOWN OF: �+ - PROPD:`�ED CONTOUR AN� rHEALT,41DEPT. YARMOUTH(PORT)� �o�o '` 3 2002 100 EXIS I T'�JG CONTOUR _ •- PREPARED FOR: RUTH ROSS PROP. VENT (FINAL PLACEMENT BY CONTRACTOR WITH 0 20 20 40 60 HOMEOWNER) BOARD OF HEALTH "--"" // U PROVED DATc M A SCALE: 1» = 20' DATE: NOVEMBER 24, 2001 off 508-362-4541 -„ fnx 508 362-99+30 BENCHMARK: CORNER PATIO AT EL. 23.9' ����N Of �Jt1 Of Mq down cape engineering, Inc, ACNE �1J��11�y H. ARNE H. G CIVIL. ENGINEERS C OJALA M 9 No. 26348 � IVI _AND SURVEYORS 939 rig In = t. -ar•Mouth, r�Ia 02675 , _ p ARNE, H. OJALA, S. ^DA TE