Loading...
HomeMy WebLinkAboutReview Checklist _ �a:r :;�.� , � TOWN OF YARM OU TH SEWAGE PLAN REVIEW CHECKLIST A i Location: A.M.�_ Lot� Zone of Contribution: In Out creage ,, , ,. �� Commercial: Residential:� Street: _ f Village: Floor Plan: #Bedrooms: �_ ` Owner: � Installer: ; Address: Phone: - - Phone: � . V � / Builder: Engineer: r Address: Phone: � � Phone: �" ,�t7 �' � �Ff /G��� �Tr'/� t 'k:�/�v� ' N/A YE NO l.Required# of copies received ' 2.Date of soils e�.m and ercolation test not older than 2 years �� i 3.4-5 ft of naturall occurrin ervious material,above water table 4.Founda.tion 2 ft above hi oint of road H.P.: Fnd: Var.: v-' i 5.Water line 10 ft from septic com onents Var.: �� ' 6.Benchmark indicated and shown-NGVD if near wetlands ✓�� 7. S tic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L�' 9.Leachin minimum 100 ft from wetlands Var.: `�-- 10.Leaching minimum 150 ft from drinkin welU25 ft irrigation well Var.: ' 11.Tank/leachin minunum 10 ft from roperty line Var.: ; 12.S stem meets all other setback r uirements Var.: � 13.Uses adjustment for maximum hi oundwater Var.: �./ 14.Leachin set 4-5 ft above adj.water or botto est 1 1.�� 15. System not in top or subsoil(A,B horizons) r 5'removal 16.Pro osed contours are suitable ' 17. S stem meets slo e re uirements-min. 1!8", '/4" eferred L.� 18. System meets breakout re uirements PVC liner: Wall: a,�-� 19. S ec�ed tee sizes are roper, gas ba.ffle on outlet tee '�---� 20. Sewa e is under 10,000 d for arcel ' '� 21.No garbage dis osal , 22. S stem ade uately sized for its intended use � 23.Minimum 6"stone or compacted below tank and dbox �"' 24.Manhole covers within 6"of ade, ump chamber cover to ade 25.Ins �tion port on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes - 27.Pump system-2" line,weep hole,check valve,tee in dbox, ump size �-� 28. Se tic tank/pum chamber to be factory wat roofed 29.Vent rovided if leaching below 3 feet,under driveway/parking �� 30.Buoyancy calculations for tank/ um chamber 31.En ' eer to ins ect and cert soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature , 33.H-20 loadin is subject to vehicular traffic, groundwater 34.Title V A plication and ermit fee, insta.11er si ature 35.Foundation footing min.2 feet above adjusted ound water for new house 'L..�' 36.Deed Restriction r uired max. #bedrooms: max. flow: d �--�' 37.Check area lots for groundwater/Label oundwater in Assessor's Map Plan reviewed by: �_ 6/03/03 i