HomeMy WebLinkAboutEngineered Plan - 2016GENERAL NOTES: SOIL TEST LOGS:
A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC SYSTEM TEST HOLE 1: EL=52.2±
UNLESS H-20 COMPONENTS ARE USED.
B.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UN-
LESS CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING.
C.) CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL
UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK.
CTI O OTES
DEPTH FROM
SURFACE
(INCHES)
SOIL
HORIZON
SOIL
TEXTURE
(USDA)
SOIL
COLOR
(MUNSELL)
SOIL OTHER
MOTTLING
0-30
Fill
fine Loam Sand
I OYR3 2
Water Level Adjustment:
30-38
Ab
Fine Loamy Sand
I 0YR3/2
NONE
38-62
B
1 Fine Sand
7.5YR7 8
NONE PERC P, 52"• <2 MIN/IN
62-126
CI
Fine Sand
I 0YR7 8 I
NONE
50.3
16 x 5 (LAYUP LENGTH) x 4.80 SF/LF = 384.0 SF
_W_
1`
49.5\gyp
CONSTI�U N N .
TEST HOLE 2: EL=52.4±
1.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE,
TITLE 5, AND THE REQUIREMENTS OF THE LOCAL BOARD OF HEALTH.
2.) SEPTIC TANK(S), GREASE TRAP(S), DOSING CHAMBERS) AND DISTRIBUTION
BOX(ES) SHALL BE SET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY
COMPACTED, OR ON A 6 INCH CRUSHED STONE BASE.
3.) SEPTIC TANKS) SHALL MEET ASTM STANDARD C 1 127-93 AND SHALL HAVE
DEPTH FROM
SURFACE
(INCHES)
0-23
SOIL
HORIZON
Fill
SOIL
TEXTURE
(USDA)
SOIL
COLOR
(MUNSELL)
OTHER
HNONE
23-32
Ab
fine Loam Sand
I OYR3 2
Water Level Adjustment:
32-53
B
Fine Sand
7.5YR7 8
PERC 47"• <2 MIN/IN
53-120
C I
Fine Sand
I OYR7 8
NONE
Proposed EL= 54.3±
DMH
TWELVE (12) ARC 36HC SIDE PORT COUPLERS - (SEE SAS DETAIL FOR LOCATION)
�D�00
? WI;�UNG
LEACHING CAPACITY:
AT LEAST THREE 20 DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT-
TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48". DATE OF TESTING: 10/27/1 G
4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G" PERCOLATION RATE: LESS THAN 2 MIN/INCH IN "B" AND "C I " LAYERS.
ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE WITNESSED BY: ROBERT REEDY, EIT, J.M. O'REILLY * ASSOCIATES, INC.
CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE. PHIL RENAUD, YARMOUTH HEALTH DEPARTMENT
GROUNDWATER ENCOUNTERED @ 1 17" IN TEST PIT #2, EL=42.7
5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM.
CONCRETE WATER TIGHT RISERS OVER INLET AND OUTLET TEES TO WITHIN G" OF
FINISH GRADE, OR AS APPROVED BY THE LOCAL BOARD OF HEALTH AGENT.
6.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL
BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN I %.
7.) DISTRIBUTION LINES FOR SOIL ABSORPTION SYSTEM (AS REQUIRED) SHALL BE
4" DIAMETER SCHEDULE 40 PVC LAID AT 0.005 FT/FT. LINE SHALL BE CAPPED
AT END OR AS NOTED.
8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST
2' BEFORE PITCHING TO SOIL ABSORPTION SYSTEM. WATER TEST DISTRIBUTION
BOX TO ASSURE EVEN DISTRIBUTION.
9.) DISTRIBUTION BOX SHALL HAVE A MINIMUM SUMP OF G" MEASURED BELOW
THE OUTLET INVERT.
HIGH GROUNDWATER LEVEL CALCULATIONS:
Depth To Water Table (10-27-16):
9.8 FEET, EL=42.7
Appropriate Index Well:
MIW-29
Water Level Range Zone:
A (0'-2')
Current Depth To Water Level For Index Well (I O/ 16):
9.8'
Water Level Adjustment:
2.7
Estimated Depth To High Water:
7.1 FEET, EL=45.4
10.) BASE AGGREGATE FOR THE LEACHING FACILITY SHALL CONSIST OF 3/4 TO SAS DETAIL
1-1 /2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST AND SHALL BE
INSTALLED BELOW THE CROWN OF THE DISTRIBUTION LINE TO THE BOTTOM OF THE
SOIL ABSORPTION SYSTEM. BASE AGGREGATE SHALL BE COVERED WITH A 2"
LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINES AND DUST. SIDE PORT CC
1 1.) VENT SOIL ABSORPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50 FEET;
WHEN LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS, PARKING AREAS,
TURNING AREAS OR OTHER IMPERVIOUS MATERIAL; OR WHEN PRESSURE DOSED.
12.) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9" OF
CLEAN MEDIUM SAND (EXCLUDING TOPSOIL).
13.) FINISH GRADE SHALL BE A MAXIMUM OF 36" OVER THE TOP OF ALL SYSTEM
COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX, DOSING CHAMBER:
AND SOIL ABSORPTION SYSTEM. SEPTIC TANKS SHALL HAVE A MINIMUM COVER
OF 9".
W
14 .) FROM THE DATE OF INSTALCATION OF THE SOIL ABSORPTION SYSTEM UNTIL
RECEIPT OF A CERTIFICATE OF COMPLIANCE, THE PERIMETER OF THE SOIL ABSORP-
TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH
AREA FOR ALL ACTIVITIES THAT MIGHT DAMAGE THE SYSTEM.
15.) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION
BY AN AGENT OF THE BOARD OF HEALTH (OR THE DESIGNER IF THIS SYSTEM RE-
QUIRES A VARIANCE) AND MAY REQUIRE SUCH PERSON TO CERTIFY IN WRITING
THAT ALL WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE
PERMIT AND APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED.
16.) EXISTING PUMP CHAMBER AND LEACH PITS) TO BE REMOVED. ANY
CONTAMINATED SOIL WITHIN 5' OF THE PROPOSED SOIL ABSORPTION SYSTEM
SHALL BE REMOVED AND REPLACED WITH CLEAN SAND. AREAS TO BE COMPACTED
TO MINIMIZE SETTLING.
17.) SOIL REMOVAL: ALL FILL AND TOPSOIL ('A' LAYER) SHALL BE REMOVED FOR
A DISTANCE OF 5' FROM THE 501L ABSORPTION SYSTEM DOWN TO THE 'B' LAYER
AT ELEVATION 49.0±. AREA TO BE BACKFILLED WITH CLEAN SAND AND COMPACTED .
TO MINIMIZE SETTLING.
FLOW PINOFI LE:
.' •
NOT TO SCALE
24" DIAMETER CONCRETE COVERS
THREE(3) COVERS
LEACHING CAPACITY REQUIRED:
RAISED TO WITHIN G" OF FINISH
3 BEDROOMS (MIN.) @ I 10 GPD = 330 GPD REQUIRED
TOP OF FOUNDATION
GRADE (OR AS NOTED)
DAILY FLOW = 330 GPD @ 200% = 660 GAL. REQUIRED
PROPOSED CONTOUR
EL=55.0
(SEE NOTE #5)
1500 GALLON SEPTIC TANK (MIN. ALLOWED)
�w
w
LEACHING CAPACITY PROVIDED:
PRpP05�D
M
'
Proposed EL= 54.3±
DMH
TWELVE (12) ARC 36HC SIDE PORT COUPLERS - (SEE SAS DETAIL FOR LOCATION)
�D�00
? WI;�UNG
LEACHING CAPACITY:
50.3
16 x 5 (LAYUP LENGTH) x 4.80 SF/LF = 384.0 SF
_W_
1`
49.5\gyp
Vt = (384.0 + 67.3) x 0.74 GPD/SF = 334 GPD > 330 GPD REQ'D
Existing Building
m
NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN.
-0-
00L
si
BENCHMARK:
ONE (1) - 1500 GALLON SEPTIC TANK (MFG: SHOREY)
N
- W
CUCL, Existing Catch Basin
53.5±
in
x 5 19
EL=49.4-}- (Assumed datum)
GAS SERVICE LINE
,
Q
�
TEST HOLE / BORING LOCATION
20
LOT 16
5TT
Approx. Location of
y
-
DB
DISTRIBUTION BOX
54.3 `
110"14"
4
3"T T
'IO"
GAS BAFFLE -
10--j 1500 GALLON
SEPTIC TANK
51.95
47.8±
�--10'
DB -6
D -BO
H-20
ZONING TABLE
R-40 ZONE
FRONT YARD SETBACK 30 FEET
SIDE AND REAR YARD SETBACKS 20 FEET
BUILDING COVERAGE 25%
PROPOSED BUILDING COVERAGE:
HOUSE * DECK AREAS
X 100
LOT AREA
1,284 SF± X 100 = 1 1.7% < 25%, OK
10,935 SF±
18" PIECE OF #5 REBAR INSTALLED NEXT TO -
INSPECTION FORT FOR FUTURE LOCATION
EL=53.0± �-Proposed EL= 53.0±
4" PVC INSPECTIO
PORT W/ SCREW CAP
RAISED TO WITHIN
3" OF GRADE.
SERVATION PORT
50.0
,SYSTEM DESIGN CALCULATIONS:
.' •
SEWAGE DESIGN FLOW:
2 BEDROOM DWELLING @ I 10 GPD = 220 GPD
SMH'
LEACHING CAPACITY REQUIRED:
-- 32
3 BEDROOMS (MIN.) @ I 10 GPD = 330 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED:
DAILY FLOW = 330 GPD @ 200% = 660 GAL. REQUIRED
PROPOSED CONTOUR
SEPTIC TANK CAPACITY PROVIDED:
1500 GALLON SEPTIC TANK (MIN. ALLOWED)
�w
w
LEACHING CAPACITY PROVIDED:
PRpP05�D
M
'
SIXTEEN (I 6) ARCH 36HC CHAMBERS - IN FIELD CONFIGURATION (SEE SAS DETAIL)
DMH
TWELVE (12) ARC 36HC SIDE PORT COUPLERS - (SEE SAS DETAIL FOR LOCATION)
�D�00
? WI;�UNG
LEACHING CAPACITY:
50.3
16 x 5 (LAYUP LENGTH) x 4.80 SF/LF = 384.0 SF
_W_
12 x 1. 17 (LAY-UP LENGTH) x 4.80 SF/LF = 67.3 SF
49.5\gyp
Vt = (384.0 + 67.3) x 0.74 GPD/SF = 334 GPD > 330 GPD REQ'D
Existing Building
m
NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN.
-0-
INSTALL:
m
BENCHMARK:
ONE (1) - 1500 GALLON SEPTIC TANK (MFG: SHOREY)
N
YARMOUTH,
ONE (1) - 6 OUTLET DISTRIBUTION BOX (H-20 Rated) d PLAN BOOK 142 PAGE 43
SIXTEEN (I 6) ARC 36HC CHAMBER UNITS DEED BOOK 25892 PAGE 331
TWELVE (12) ARC 36HC SIDE PORT COUPLER UNITS
FOUR (4) ARC 36HC END UNITS ASSESSORS' MAP 50 PARCEL 79
FOUR (4) ARC 36HC SPLASH PADS m
THREE (3) - 24" DIA ACCESS COVERS TO GRADE WITH RISERS.
ONE (1) - 4" OBSERVATION PORT, SEE PROFILE LEG E N D
�0
Guywire,
5UP
Z ., i�x52�
50.9 D�1v�WPI �-
49.7'
`5 53x5
•
.' •
.x 3,0 1
.e
SMH'
-- 32
EXISTING CONTOUR
�w
32
PROPOSED CONTOUR
Existing Chamlmk Fence
TO BE REMOVED
�w
w
EXISTING SPOT GRADE
PRpP05�D
M
'
N
DMH
c 52.5r0
► 1 `
�D�00
? WI;�UNG
50.3
_W_
PROPOSED WATERLINE
49.5\gyp
05 2
Existing Building
TO BE DEMOLISHED
-0-
OVERHEAD UTILITY SERVICE
BENCHMARK:
-
49.5
UNDERGROUND UTILITY SERVICE
- W
CUCL, Existing Catch Basin
x 5 19
EL=49.4-}- (Assumed datum)
GAS SERVICE LINE
,
Q
�
TEST HOLE / BORING LOCATION
20
LOT 16
5TT
Approx. Location of
y
-
I I" Prbposed
(9" Min - 36" Max)
Existing Pump Chamber Area= 10,935 SF± x 53.
SEE NOTE 16 ro
TP7
c 52.2 + 0 5Ax3 5� .�■
49.6 x 51.5
x 52.4 RESERVE
vz N x52.3
n �� 51.5 /7 6.23'
sz.zx
07
49.7 Edge of Pavement
SO
Existing Catch Basm�
Rim EL=49.8± J U I ITE 1` LANE
(40' Wlde - Public Way)
x 53.1 ® �O
S�
/ / x 52 q
O
1+
\Curb
Approx. Location of
Exlstmcj Leach Pit(5)
SEE NOTE to
Yarmouth Hcalth Department
�N�QV
52.1
UP/70-
�c 52.1
PLAN
SCALE0'
THIS AREA IS SERVED
BY TOWN WATER.
IR INSPECTION NOTE:
111 r 51.70 PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM
51.75 50.80 NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS.
2" DROP STONELESS SYSTEM
5.4'±
23.77' (SEE DETAIL)
Longest Run USE 16 ARC 36HC CHAMBERS WITH
8' 12 SIDE PORT COUPLERS �- -L=45.4± ESTIMATED SEASONAL HIGH GROUNDWATER
IN FIELD CONFIGURATION (SEE SAS DETAIL) 2.7
�( (SIDE VIEW)
-3- EL=42.7± OBSERVED GROUNDWATER, 10/27/16
LEACHING FIELDS 0 20 40 60
23.77'x I 1.52'x 0.9'
SCALE 1 "=20'
G:WAJobs\The Davenport Companie5\8232 - 24 Mars lane S. Yarmouth\dwci\8232.S5DS Plan.d%
JOHN
ISR.
GREILL`s
NO. 46733
'�fiCSt.w
JOHN V.
O'REILLY
CIVIL
NO. 35200
,� +"
The Davenport Companies
20 North Main Street, South Yarmouth, MA 02664
51TE � SEWAGE DISPOSAL 5Y5TEM DESIGN
24 MARS LANE, 5. YARMOUTH, MA
J.M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1573 Main Street - Route 6A
P.O. Bog 1773
(508)896-6601 Office Brewster, MA 02631 (508)896-6602 Fax
DATE: SCALE: BY:CHECK: JOB NUMBER:
1 11411 G AS Noted RFR JMO JMO-8232
r..
-- 32
EXISTING CONTOUR
32
PROPOSED CONTOUR
X 12.34
EXISTING SPOT GRADE
24x5
PROPOSED SPOT GRADE
50.3
_W_
WATER SERVICE LINE
Existing Building
TO BE DEMOLISHED
-0-
OVERHEAD UTILITY SERVICE
--
-u-
UNDERGROUND UTILITY SERVICE
x 5 19
-G-
GAS SERVICE LINE
�
TEST HOLE / BORING LOCATION
20
5TT
SEPTIC TANK
DB
DISTRIBUTION BOX
54.3 `
SAS
SOIL ABSORPTION SYSTEM
_ , \
Reserve
RESERVED FOR FUTURE
�
®
UTILITY POLE
CATCH BASIN
�
FIRE HYDRANT
x4s
__
G
WELL
DRAINAGE MANHOLE
\
CONCRETE BOUND, FOUND
_ _
---TOP
Of-BANK-
F -BANK
-
32
LIMIT
LIMIT OF WORK
52.9
FENCE
x 51.9
... �.M�
EDGE OF CLEARING
Existing Pump Chamber Area= 10,935 SF± x 53.
SEE NOTE 16 ro
TP7
c 52.2 + 0 5Ax3 5� .�■
49.6 x 51.5
x 52.4 RESERVE
vz N x52.3
n �� 51.5 /7 6.23'
sz.zx
07
49.7 Edge of Pavement
SO
Existing Catch Basm�
Rim EL=49.8± J U I ITE 1` LANE
(40' Wlde - Public Way)
x 53.1 ® �O
S�
/ / x 52 q
O
1+
\Curb
Approx. Location of
Exlstmcj Leach Pit(5)
SEE NOTE to
Yarmouth Hcalth Department
�N�QV
52.1
UP/70-
�c 52.1
PLAN
SCALE0'
THIS AREA IS SERVED
BY TOWN WATER.
IR INSPECTION NOTE:
111 r 51.70 PRIOR TO FINAL INSPECTION BY THE ENGINEER, SYSTEM
51.75 50.80 NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS.
2" DROP STONELESS SYSTEM
5.4'±
23.77' (SEE DETAIL)
Longest Run USE 16 ARC 36HC CHAMBERS WITH
8' 12 SIDE PORT COUPLERS �- -L=45.4± ESTIMATED SEASONAL HIGH GROUNDWATER
IN FIELD CONFIGURATION (SEE SAS DETAIL) 2.7
�( (SIDE VIEW)
-3- EL=42.7± OBSERVED GROUNDWATER, 10/27/16
LEACHING FIELDS 0 20 40 60
23.77'x I 1.52'x 0.9'
SCALE 1 "=20'
G:WAJobs\The Davenport Companie5\8232 - 24 Mars lane S. Yarmouth\dwci\8232.S5DS Plan.d%
JOHN
ISR.
GREILL`s
NO. 46733
'�fiCSt.w
JOHN V.
O'REILLY
CIVIL
NO. 35200
,� +"
The Davenport Companies
20 North Main Street, South Yarmouth, MA 02664
51TE � SEWAGE DISPOSAL 5Y5TEM DESIGN
24 MARS LANE, 5. YARMOUTH, MA
J.M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1573 Main Street - Route 6A
P.O. Bog 1773
(508)896-6601 Office Brewster, MA 02631 (508)896-6602 Fax
DATE: SCALE: BY:CHECK: JOB NUMBER:
1 11411 G AS Noted RFR JMO JMO-8232