Loading...
HomeMy WebLinkAboutEngineered Plans - 201742---- — — — — — AREAS -4810.4 sf+— 70 4 I GAN ��P PLAN SCALE: 1 in = 20 ft 0 20 40 0 10 20 40 IBM = EL. 40.7 WATER GATE Yarmouth Health Department Date SURVEY BY: WELLER AND ASSOCIATES SOUTH YARMOUTH L�US LOCUS MAP LOCUS INFORMATION PLAN REF: 343/UU4 TITLE REF: D981852 PARCEL ID: MAP 99 PAR. 039 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 190 BEACON STREET SOUTH YARMOUTH, MA PREPARED FOR ISAAC JOSEPH APRIL 2, 2017 t0 s MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmoil.com SHEET 1 OF 2 J#1894 LEGEND 39, PROPOSED CONTOUR 40 ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR 25 0 O' + 96.52 EXISTING SPOT GRADE 41 \ 39 W— EXISTING WATER SERVICE TEST PIT 12 SCALE: 1"=20' ` \ \ 0 25,0 w fl 40 - 1 \ �X1Sj1NG �EP�N`NG\ EXISTIN-G, 1,000G , No SEPTIC\TANK o 9 \ w i \ \ o ) o 42---- — — — — — AREAS -4810.4 sf+— 70 4 I GAN ��P PLAN SCALE: 1 in = 20 ft 0 20 40 0 10 20 40 IBM = EL. 40.7 WATER GATE Yarmouth Health Department Date SURVEY BY: WELLER AND ASSOCIATES SOUTH YARMOUTH L�US LOCUS MAP LOCUS INFORMATION PLAN REF: 343/UU4 TITLE REF: D981852 PARCEL ID: MAP 99 PAR. 039 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 190 BEACON STREET SOUTH YARMOUTH, MA PREPARED FOR ISAAC JOSEPH APRIL 2, 2017 t0 s MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmoil.com SHEET 1 OF 2 J#1894 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH TOF SEPTIC TANK M. MEYER, GRADE SHALL NOT BE < EL:39.10 FOR A DISTANCE INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX 15' AROUND THE PERIMETER OF THE S.A.S. EL.=42.50f OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER &COVER PROPOSED S.A.S. INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6 OF GRADE INSTALL A RISER OVER ONE CHAMBER (MIIN) F.G. EL.=42.Ot F.G. EL.=41.0f F.G. EL: 41.501 AND SET TO 3" OF F.G. fF.G. EL: 41.50(MAX.) 9" MIN COVER/ 41.43 ' 36" MAX COVER L = 65' ® S=1X (MIN.) EL,a40.40t O S=1X (MIN.) L = 15'(MAX) 1' O S=1X (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC 2" OF 3/8" DOUBLE WASHED 3/4" - 1-1/2" 1./1 STONE OR FILTER FABRIC DOUBLE WASHED STONE 6 INV.=39.35 14 �INV 39.43 48" LIQUID tEt�t r ®®®®• O ®®®® PROPOSED ®®®awaE E3®® GAS aoFFLEJ D-80 ®®®®®®®®®®® -77 777777-INV.=38.45 INV.=38.25 DB -5 O 38.0 EXISTING 1.000 GALLON SEPTIC TANKS MEDIUM 4' 2 X 8.5' 4' EXIST. SEWER OUTLET EFFECTIVE LENGTH = 25.0' INV. ELEV.= 38.10 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING BREAKOUTEL. PIPE INVERTS PRIOR TO CONSTRUCTION 39.10 TOP CONC. ELEV.= 39.10 2) D -BOX SHALL BE SET LEVEL AND TRUE TO . ELEV..' INV = 3810 GRADE ON A MECHANICALLY COMPACTED SIX ®a® INCH CRUSHED STONE BASE, AS SPECIFIED IN ®6®8®®® a®®®BBB 310 CMR 15.221(2) BOTTOM EL.= 36.1080,63®a® 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK 4' 5 FT. 4' WITH 1500 GALLON SEPTIC TANK IF FAILED, SEPARATION 4.25 FT.* EFFECTIVE WIDTH = 13' DAMAGED, NOT H2O LOADING, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ 11 SOIL ABSORPTION SYSTEM (SECTION) GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE BOTTOM OF TESTHOLE EL: 31.85 (500 GALLON (H20) LEACH CHAMBER) *VERIFY 5 FT. SEPARATION AT'TIME OF INSTALL N.T.S. SOIL LOGS DATE: APRIL 2, 2017 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. TP -1 Depth 42.10 A 0" LOAMY SAND 10YR 4/1 41.43 8" B LOAMY SAND 10YR 5/8 39.43 32" C PERC TEST O 38.0 MEDIUM SAND 2.5Y 6/4 31.85 123" PERC RATE <2 MIN/IN. ("Cl' HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluationsand that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. OF Mqs� D E M" o.14 S1 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. B. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. PROPERTY IS LOCATED IN A GROUNDWATER PROTECTION DISTRICT. DESIGN CRITERIA NUMBER OF BEDROOMS: EXIST. 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERC RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. USE �NITAR�t USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS AND 4' ON SIDES: 25' L x 13' W x 2' D BOTTOM AREA: 25 x 13 = 325 SF SIDE AREA: (25 + 13) X 2 X 2 = 152 SF TOTAL SQUARE FEET PROVIDED = 477 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(477 S.F.) = 352.98 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 's 190 BEACON STREET, SOUTH YARMOUTH, MA Prepared for: Joseph System Design and Topography Plan by: SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 04/02/17 POBOX981 y � EAST SANDWICH, MA 02537 REV DATE CHECKED SHEET NO. 5083522822 DMM 2 of 2