HomeMy WebLinkAboutEngineered Plan - Rev. 2016LO C US MAP SCALE: N.T.S. N/F SULLIVAN MAP 68 LOT .163 #342 LONG POND DRIVE C,y rQom' G 4 R03 RT VV. o U CAVI! RQgERT W. CROW�LL P.E. CERTIFY THAT THIS PLAN CONFORMS TO TITLE 5 SND THE YARMOUTH B.O.H. REGULATIONS. PUMP TO BE EQUIPPED WITH AN ALARM LOCATED IN BRING RISERS TO WITHIN SOIL MOTTLING THE BUILDING WHICH IS POWERED BY A CIRCUIT 6" OF GRADE AS REQUIRED WITNESSED BY: j SEPARATE FROM THE CIRCUIT TO i THE PUMPS. APPROX. M. S L. J SCH 40 CHILD PROOF COVER RISER AT OUTLET TEE TO WATER TIGHT ACCESS MIH. TOP OF FDN GRADE WITH SECURED COVER JUNCTION BOX 2.5Y6/8 RfCI SiER�� J�i� s/DNC AND '� Wrr PVC ELECTRICAL PIPE 21 2 FLOAT HANGER MIN. LEACHING AREA= 550 GPD/0.74 GPD/SF= 743 SF BOTTOM OF CHAMBER 15.70 2"TO 4" INLET FROM PUMP TO PUMP CONTROLSEXPANDER/,CHAMBER USING INFILTRATOR QUIK4'S (SEE DETAIL _ AA) IN BUILDING DETACHABLE FLANGE „ POLY PROPELENE LIFTING LINE 157.5 FT/4FT/UNIT = 39.4 UNITS EXISTING BUILDING SEWER PROP.1500 GAL 4" PVC PIPE FLOAT SWITCHES 2 F M' SEPTIC TANK (SCH. 40) M 1-1 4" PVC PIPE 11.Ot VALVE 1/4"4 HOLE AT 18 7 MIN. SLOPE 6" MIN (SCH. 40) va INVERT OF PIPE DETAIL AA 02 - Z ALARM 0 19 3 b 14" MIN. SLOPE L PROVIDE 1/2 C.Y. OF +.zs' ON 10.81 CONCRETE TO FORM SLOPED= BOTTOM AND PUMP SUMP `D 4 OFFWITHIN EXISTING TANK 6.8t USE MEYERS SRM4 4/10 HP SUBMERSIBLE SEWAGE PUMP, 2" 30" SOLIDS HANDLING CAPABILITY EXISTING 19000 GAL SEPTIC TANK EXISTING TANK TO BE CONVERTED FOR USE AS A PUMP CHAMBER. PUMP AND CLEAN TANK. REMOVE EXISTING INLET AND OUTLET TEES. PROVIDE WATERTIGHT SEAL BETWEEN 2" i DISCHARGE PIPE TANK. REMOVE EXISTING 4" DISCHARGE PIPE AND PROVIDE WATERTIGHT s PLUG AT EXISTING OPENING. yF0 �! AN ELECTRICAL PERMIT IS REQUIRED '�. LONG POND tt N (GREA T POND) tt 12" \ POND ELEVATION 11/30/16 �6, = 8.2 FT t \ �7, y TOA r I 1 d D,n 6 Q ; � .....•.`-" ", ONO t: EDGE FPA t/EME LONG POND DRIVE /E (PUBLIC - 40'; WIDE) CB N/F WISNIEWSKI MAP 68 L 0 T 165 #320 LONG POND DRIVE GRAPHIC SCALE d ( IN FEET ) 1 inch = 20 ft. 01 18.7 �18.45 =/ ZABEL FILTER SANITARY TEE A100 SUPPORT LEG ypraypr VerapO-aVQ�aypr4pra 0 avpray 25.5' ° r0y �r2 0 oa4 8 o e 2 Q °004 g9 46' OgO o 000 40)0,00 0 °Q0 o0), 00 6" CRUSHED STONE PROP. 1500 GALLON SEPTIC TANK (NEW TANK AT FRONT OF HOUSE) PUMP FLOW CALCULATIONS PUMPED VOLUME=99 GAL DRA4'i'EA_f'X VO UME=24 GAL NET FORWARD FLOW=99 GAL -24 GAL=75 GAL CYCLES PER DAY = 220 GPD/75 GAL = 3 CYCLES PER DAY PUMP HEAD CALCULATIONS STATIC HEAD = 18.7'-7.5'=11.2' PUMP RATE = 33 GPM FRICTION LOSS = 2.8 FT TDH= 11.2+2.8=14 FT PUMP CHAMBER RESERVE CAPACITY (VOLUME & TIME) RESERVE CAPACITY AFTER ALARM = 2.25'x4'x8'x7.48 GAL/CF = 539 GAL 625 GAL-. 220 GPD = 2.8 DAYS RESERVE CAPACITY PUMP CHAMBER - 1000 GAL SEPTIC TANK W/RISER TO GRADE ACCESSING PUMP - MUST BE MADE WATER TIGHT PUMP USE MEYERS SRM4 SEWAGE PUMP OR EQUAL 4/10 HP HANDLE 2" 0 SOLIDS RUN TIME PER PUMP CYCLE 99 GAL/33 GPM = 3 MIN CONTROL PANEL REQUIREMENTS SIMPLEX CONTROLLER WITH ALARM, MUST BE INSIDE BLDG - OFF -AUTO -ON SWITCH (MINIMUM 3 SWITCH SYSTEM) - ALARM WITH LIGHT AND BUZZER/BELL - ALARM SILENCE BUTTON MUST BE OUTSIDE - ALARM TEST SWITCH - ALARM ON SEPARATE CIRCUIT FROM PUMP FORCE MAIN - 2" 0 P.E. PIPE OR SCH. 40 PVC - FORCE MAIN TO HAVE AN UPWARD SLOPE (NO -SAGS) FROM PUMP CHAMBER TO D -BOX W DRAIN BACK CAPABILITY. PUMP CHAMBER BUOANCY CALCULATION TANK BASE ELEV=6.2 FT GROUNDWATER ELEV=10.5 FT SUBMERGED DEPTH=10.5 FT -6.2 FT=4.3 FT BUOYANT FORCE=4.3 FTx4.5 FTx8.5 FTx62.5 LB/CF=10280 LB TANK WEIGHT=8750 LB CONC. BALAST WEIGHT=0.5 CYx27 CF/CYx10 LB/CF=1890 LB SOIL COVER =4.5 FTx8.5 FTx 0.5 FTx 110 LB/CF=2100 LB TOTAL WEIGHT=8750 LB+1809 LB+2100 LB=12740 LB NET FORCE=12740 LB -10280 LB=2460 LB DOWN BRING RISER TO WITHIN 6" OF GRADE INSPECTION PORT CHARCOAL 12" MIN. COVER I VENT GRADE 36" MAX. FINISHED 2 x e 2% MIN• SLOP T2 MW LEVEL E SOIL MOTTLING BENCH MARK FILL TOP OF CB 1 WITNESSED BY: ELEV=24.48 NO MOTTLINGVERY APPROX. M. S L. J SCH 40 10YR4/1 Of v�sf9c Bb o SHELDON yN J o ROBERT C PHINNEY H No. 33608 90�� 2.5Y6/8 RfCI SiER�� J�i� s/DNC AND '� Wrr 16.37 �� V N/F WISNIEWSKI MAP 68 L 0 T 165 #320 LONG POND DRIVE GRAPHIC SCALE d ( IN FEET ) 1 inch = 20 ft. 01 18.7 �18.45 =/ ZABEL FILTER SANITARY TEE A100 SUPPORT LEG ypraypr VerapO-aVQ�aypr4pra 0 avpray 25.5' ° r0y �r2 0 oa4 8 o e 2 Q °004 g9 46' OgO o 000 40)0,00 0 °Q0 o0), 00 6" CRUSHED STONE PROP. 1500 GALLON SEPTIC TANK (NEW TANK AT FRONT OF HOUSE) PUMP FLOW CALCULATIONS PUMPED VOLUME=99 GAL DRA4'i'EA_f'X VO UME=24 GAL NET FORWARD FLOW=99 GAL -24 GAL=75 GAL CYCLES PER DAY = 220 GPD/75 GAL = 3 CYCLES PER DAY PUMP HEAD CALCULATIONS STATIC HEAD = 18.7'-7.5'=11.2' PUMP RATE = 33 GPM FRICTION LOSS = 2.8 FT TDH= 11.2+2.8=14 FT PUMP CHAMBER RESERVE CAPACITY (VOLUME & TIME) RESERVE CAPACITY AFTER ALARM = 2.25'x4'x8'x7.48 GAL/CF = 539 GAL 625 GAL-. 220 GPD = 2.8 DAYS RESERVE CAPACITY PUMP CHAMBER - 1000 GAL SEPTIC TANK W/RISER TO GRADE ACCESSING PUMP - MUST BE MADE WATER TIGHT PUMP USE MEYERS SRM4 SEWAGE PUMP OR EQUAL 4/10 HP HANDLE 2" 0 SOLIDS RUN TIME PER PUMP CYCLE 99 GAL/33 GPM = 3 MIN CONTROL PANEL REQUIREMENTS SIMPLEX CONTROLLER WITH ALARM, MUST BE INSIDE BLDG - OFF -AUTO -ON SWITCH (MINIMUM 3 SWITCH SYSTEM) - ALARM WITH LIGHT AND BUZZER/BELL - ALARM SILENCE BUTTON MUST BE OUTSIDE - ALARM TEST SWITCH - ALARM ON SEPARATE CIRCUIT FROM PUMP FORCE MAIN - 2" 0 P.E. PIPE OR SCH. 40 PVC - FORCE MAIN TO HAVE AN UPWARD SLOPE (NO -SAGS) FROM PUMP CHAMBER TO D -BOX W DRAIN BACK CAPABILITY. PUMP CHAMBER BUOANCY CALCULATION TANK BASE ELEV=6.2 FT GROUNDWATER ELEV=10.5 FT SUBMERGED DEPTH=10.5 FT -6.2 FT=4.3 FT BUOYANT FORCE=4.3 FTx4.5 FTx8.5 FTx62.5 LB/CF=10280 LB TANK WEIGHT=8750 LB CONC. BALAST WEIGHT=0.5 CYx27 CF/CYx10 LB/CF=1890 LB SOIL COVER =4.5 FTx8.5 FTx 0.5 FTx 110 LB/CF=2100 LB TOTAL WEIGHT=8750 LB+1809 LB+2100 LB=12740 LB NET FORCE=12740 LB -10280 LB=2460 LB DOWN BRING RISER TO WITHIN 6" OF GRADE INSPECTION PORT CHARCOAL 12" MIN. COVER I VENT GRADE 36" MAX. FINISHED 2 x e 2% MIN• SLOP T2 MW LOCAL UPGRADE APPROVAL REQUEST ALLOW THE MAXIMUM COVER OVER THE SAS TO GO FROM 3 FEET TO 4.81 -FT. THE VENT WILL MAKE THIS SYSTEM WORK FINE. CONSTRUCTION NOTES 1. PUMP EXISTING CESSPOOLS, REMOVE OR CRUSH & FILL W/GRAVEL 2. PLACE NEW TANK & INSTALL A100 ZABEL FILTER W/SUPPORT LEG J. EXCAVATE FOR SAS INSPECTION SCHEDULE B.O.H. TO INSPECT STONE BENEATH SEPTIC: TANK. BOTTOM OF EXCA VA TION INSPECTION TD BE W/ TNESSED BY B. 0. H. & ENGINEER B.O.H. TO INSPECT TANKS, DBOX, AND SAS PIPING. ENGINEER TO INSPECT AND CERTIFY PIPE INVERTS AND COMPONENTS, AND PREPARE AN AS -BUILT PLAN. w o' N,4 0" 0 w 30" 1 38" 46" 123" SOIL HOR. LEVEL E SOIL MOTTLING OTHER FILL 4" PVC WITNESSED BY: 5 -BEDROOM DESIGN NO MOTTLINGVERY -- Ab SCH 40 10YR4/1 16.7 Bb _ 6" SAND 10YR5/8 0.67' 16.60 C 15.7 2.5Y6/8 SINGLE GRAIN LOOSE wpaver�e�apo 0 8 oy°o`Q�o e o 16.37 i 't MIN. LEACHING AREA= 550 GPD/0.74 GPD/SF= 743 SF BOTTOM OF CHAMBER 15.70 LEACHING AREA: GROUNDWATER SEPERATION i USING INFILTRATOR QUIK4'S ADJUSTED GROUNDWATER 2.83' 2.83' 2.83' 2.83' 2.83' 743 SF/4.72 SF/LF= 157.5 FT 157.5 FT/4FT/UNIT = 39.4 UNITS USE 5 -ROWS OF 8 = 40 UNITS VARIES 42.34 `V 14.15' 40 UNITS x 4 FT x 4.72 SF/FT=755 S.F. 40-QUICK4 STANDARD INFILTRATORS 5 -ROWS OF 8-QUICK4'S S� STANDARD INFILTRATORS D -- BOX LEACHING 10.5 HI FIELD - GROUNDWATER LEACHING FIELD 7 -OUTLETS X -SECTION 2 -PLUGGED PLAN& PROFILE SITE NOTES 1. OWNERS: MURIEL E.WELDON TRUSTEE 2. DEED REFERENCE: BK 21101 PG 278 3. ASSESSORS: MAP 68 LOT 164 4. RC ZONE, AQUIFER PROTECTION OVERLAY DISTRICT 5. THIS LOT DOES NOT FALL IN A FLOOD PLAIN AS SHOWN ON 6' COMMUNITY PANEL NO. 25001CO587J 07-16-2014. THERE v SOIL TEST DATA ARE NO KNOWN WETLANDS WITHIN 100' OF THE PROPOSED SEWAGE ABSORPTION SYSTEM. TP N0. 1 1 7. THERE ARE NO KNOWN POTABLE WELLS LOCATED WITHIN 200' OF THE 0 - PROPOSED LEACHING FACILITY. LOCAL UPGRADE APPROVAL REQUEST ALLOW THE MAXIMUM COVER OVER THE SAS TO GO FROM 3 FEET TO 4.81 -FT. THE VENT WILL MAKE THIS SYSTEM WORK FINE. CONSTRUCTION NOTES 1. PUMP EXISTING CESSPOOLS, REMOVE OR CRUSH & FILL W/GRAVEL 2. PLACE NEW TANK & INSTALL A100 ZABEL FILTER W/SUPPORT LEG J. EXCAVATE FOR SAS INSPECTION SCHEDULE B.O.H. TO INSPECT STONE BENEATH SEPTIC: TANK. BOTTOM OF EXCA VA TION INSPECTION TD BE W/ TNESSED BY B. 0. H. & ENGINEER B.O.H. TO INSPECT TANKS, DBOX, AND SAS PIPING. ENGINEER TO INSPECT AND CERTIFY PIPE INVERTS AND COMPONENTS, AND PREPARE AN AS -BUILT PLAN. w o' N,4 0" 0 w 30" 1 38" 46" 123" SOIL HOR. SOIL TEXTURE SOIL �OLOR SOIL MOTTLING OTHER FILL -- WITNESSED BY: 5 -BEDROOM DESIGN NO MOTTLINGVERY -- Ab SANDY LOAM 10YR4/1 VERY FINE Bb SANDY LOAM 10YR5/8 FINE C COARSE SAND 2.5Y6/8 SINGLE GRAIN LOOSE NO GROUND WATER ENCOUNTERED PERC TESTS 8. THERE ARE NO KNOWN IRRIGATION WELLS LOCATED WITHIN 200' OF THE PROPOSED LEACHING FACILITY. 9. THIS PROPERTY FALLS WITHIN A ZONE II WELL PROTECTION AREA, 21.0 AS SHOWN ON DEP-TITLE V SETBACK AREAS MAP. 10. THIS DESIGN DOES REQUIRE VARIANCES TO TITLE 5 (310 CMR 15.00) 18.5 OR THE YARMOUTH SUPPLEMENTAL REGULATIONS. 11. TOPOGRAPHIC DETAIL, NATURAL AND MAN MADE SURFACE FEATURES 17.8 ARE BASED ON AN ON GROUND SURVEY BY S.R.PHINNEY & CROWELL ENGINEERING. 12. THERE ARE NO EASEMENTS FOR THIS PROPERTY. 16.8 13. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH 1" WASHERS. 10.8 GENERAL NOTES 1. ALL ELEVATIONS REFER TO AN ASSUMED BENCH MARK (APPROX. NGVD) SEE PERC # PERFORMED BY: DATE DEPTH RATE S.R. PH NNEY 11-30-16 WITNESSED BY: 5 -BEDROOM DESIGN SEPTIC TANK INLET 18.70 1 S.R.PHINNEY ROBERT CROWELL 11-30-16 46" 2 MPI AMY von HONE 'I DEEP iHOLES TEST PIT # PERFORMED BY: DATE WITNES ED BY: 1 I - S.R. PH NNEY 11-30-16 rAMY Von HONE THE CORRECTION FOR THE GROUND WA TER IS 2.3 FEET. THE POND ELVE VA TION WAS 8.2 FEET. 1 8.2+2.3=10.5 GROUND WA TER ELEVATION DESIGN DATA DESIGN ELEVATIONS SINGLE FAMILY RESIDENCE TOP OF FOUNDATION 21.20 EXISTING 5 -BEDROOM INV 0 FOUNDATION 19.30 5 -BEDROOM DESIGN SEPTIC TANK INLET 18.70 DESIGN FLOW 5 x 110 GPD/BDRM = 550 GPD OUTLET 18.45 550 GPD x 200% =1100 GAL USE 1500 GAL TANK D -BOX INLET 16.77 GARBAGE GRINDER NOT ALLOWED OUTLET 16.60 DESIGN PERC RATE: 2 MPI TOP OF CHAMBER 16.70 CLASS I SOIL TYPE, LTAR = 0.74 GPD/SF INV 0 INFILTRATOR 16.37 MIN. LEACHING AREA= 550 GPD/0.74 GPD/SF= 743 SF BOTTOM OF CHAMBER 15.70 LEACHING AREA: GROUNDWATER SEPERATION 5.2' USING INFILTRATOR QUIK4'S ADJUSTED GROUNDWATER 10.50 743 SF/4.72 SF/LF= 157.5 FT 157.5 FT/4FT/UNIT = 39.4 UNITS USE 5 -ROWS OF 8 = 40 UNITS TOTAL LEACHING AREA= 40 UNITS x 4 FT x 4.72 SF/FT=755 S.F. LEACHING RATE= 755 S.F. x 0.74 GPD/SF=558 GPD I I MASTER BEDRM LIVING RM FAA ATH FRONT ENTTY SUN ROOM KITCHEN GARAGE BA7H BED RM BED RM FIRST FLOOR I BEDRM GAME RM '' CARD ROOM unuTY BAR RM STORAGE IH 2 a BED RM BASEMENT FLOOR PLANS Permit'valid for REPAIR 0I` SEPUIC SYSTE'NI ONLY, dile to State and Liwai septic variances. Board of Health review and approval is required Ior any future additionsheuuaatious/:+iterations to sewage facilities andlor structsores/d.+cuing. Yarmouth Health Della rt[licit t llf"RoVE.t) 1.4ixA ame Date MAR 0 9 2017 HEALTH DEPT. PLAN FOR LOCATIONS. 2. ALL CONSTRUCTION SHALL CONFORM TO 310 CMR 15.00, TITLE V AND THE REGULATIONS OF THE YARMOUTH BOARD OF HEALTH. 3. THIS PLAN DOES NOT WARRANT OR IMPLY ANY SUBSURFACE SOIL CONDITIONS OTHER THAN THOSE OBSERVED AT THE IMMEDIATE TEST PIT LOCATIONS. IF UNSUITABLE MATERIAL IS ENCOUNTERED, ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. 4. ALL TANKS, D -BOXES, AND CHAMBERS SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OF CRUSHED STONE. 5. IF THE D -BOX IS DOSED OR THE INLET SLOPE EXCEEDS 8%, AN INLET TEE SHALL BE REQUIRED. 6. AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED TO MINIMIZE EROSION. THE AREA OVER THE SYSTEM SHALL BE GRADED TO A MINIMUM OF 2% SLOPE TO PROVIDE POSITIVE SURFACE DRAINAGE. 7. THIS PLAN SHALL NOT BE USED FOR THE REPRODUCTION OF PROPERTY LINES, NOR SHALL IT BE USED AS A MORTGAGE PLOT PLAN OR TITLE SURVEY. CONFORMANCE TO LOCAL BYLAWS SHALL BE DETERMINED BY THE OWNER PRIOR TO CONSTRUCTION. 8. THE OWNER IS RESPONSIBLE FOR THE DETERMINATION OF THE LOCATIONS OF ALL BURIED UTILITIES. 9. FOR PROPER PERFORMANCE, THE SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND PUMPED WHEN THE TOTAL DEPTH OF SOLIDS EXCEEDS 1/4 THE LIQUID DEPTH OF THE TANK. 10. ANY ALTERATIONS MUST BE REPORTED TO THE DESIGN ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 11. THE SYSTEM MUST BE INSPECTED BY THE BOARD OF HEALTH OR ITS AGENT AND BE CERTIFIED BY THE DESIGN ENGINEER. 12. NO STRUCTURE MAY BE CONSTRUCTED OVER THE RESERVE AREA. 13. CONSERVATION COMMISSION APPROVAL MAY BE REQUIRED. 14. THE SYSTEM SHALL BE VENTED AS SHOWN. 15. SEE 310 CMR 15.255 FOR FILL SPECIFICATIONS. SEE 310 CMR 15.247 FOR AGGREGATE SPECIFICATIONS. BOARD OF HEALTH CONDITIONS 1. THE PROPOSED SEWAGE DISPOSAL SYSTEM SHALL MEET THE APPLICABLE TITLE 5 WETLANDS SETBACKS AS SET FORTH BY THE HEALTH DEPARTMENT. 2. A "WORK LIMIT" LINE SHALL BE ESTABLISHED WITH EROSION CONTROLS (LE STRAW BALES, STAKED FILTER FABRIC, BARK MULCH, "SILT SACKS," PRODUCTS MADE WITH RICE STRAW, AND OTHER WEED -FREE PRODUCTS OR APPROVED BY THE COMMISSION.) HAY BALES ARE NOT ALLOWED. IT IS THE APPLICANT'S RESPONSIBILITY TO IMPLEMENT AND MAINTAIN APPROPRIATE AND ADEQUATE EROSION CONTROLS MEASURES THROUGHOUT THE CONSTRUCTION PROCESS. 3. NO WORK OF ANY KIND SHALL OCCUR ON THE RESOURCE AREA SIDE OF THE WORK LIMIT LINE. THIS LINE SHALL BE ESTABLISHED PRIOR TO ANY CONSTRUCTION OR WORK. 4. ALL IMPORTED FILL SHALL BE CLEAN AND NOT CONTAIN ANY FOREIGN DEBRIS SUCH AS CEMENT, BITUMINOUS CONCRETE, RUBBER, METAL, TRASH, BOULDERS, ETC. 5. DEBRIS, INCLUDING LITTER, SHALL BE PICKED UP IMMEDIATELY. ANY EXCESS MATERIAL THAT IS EXCAVATED FROM THE JOB SITE SHALL BE DISPOSED OF AT A LOCATION APPROVED BY THE CONSERVATION ADMINISTRATOR OR IN A COVERED DUMPSTER. NO DEBRIS SHALL BE ALLOWED IN A WETLAND OR WATERWAY. 6. WASHING OF EQUIPMENT/TOOLS SHALL BE DONE OFF-SITE OR HANDLED IN A MANNER APPROPRIATE BY THE CONSERVATION ADMINISTRATOR. 7. NO EQUIPMENT SHALL BE REFUELED, NOR SHALL FUEL BE STORED WITHIN 100 FEET OF A RESOURCE AREA. 8. THE CESSPOOL IS TO BE PUMPED DRY, THE CONNECTION BROKEN, AND FILLED WITH CLEAN SAND. 9. ANY AREA THAT IS DISTURBED DURING CONSTRUCTION SHALL BE REVEGETATED IMMEDIATELY OR AS SOON AFTER AS THE GROWING SEASON COMMENCES. PERMANENT STABILIZATION SHALL BE CARRIED OUT IN ORDER TO MINIMIZE EROSION. THIS DOCUMENT HAS BEEN PROVIDED TO THE CLIENT WITH CERTAIN CAVEATS AND VERBAL WARNINGS CONCERNING ITS USE AND RELIABILITY. THIS DOCUMENT WAS INTENDED FOR A SPECIFIC USE DURING A SPECIFIC TIME PERIOD. IF THIS DOCUMENT IS IN THE POSSESSION OF ANY PERSON THAN THE CLIENT OR ITS AUTHORIZED AGENT, THE SEAL, SIGNATURE, AND CERTIFICATION ARE REVOKED. RELIANCE ON THE DOCUMENT BY ANY PERSON AFTER DEC 2018 COULD LEAD TO SERIOUS DAMAGES OR UNEXPECTED CONSEQUENCES. SEWAGE DISPOSAL SYSTEM REPAIR 330 LONG POND DRIVE YARMOUTH, MA PREPARED FOR: MURIEL E. WELDON, TR CR 0 WELL ENGINEERING 981 LONG POND ROAD PLYMOUTH, MA 02360 774-283-0443 DATE: 12-12-16 SCALE: 1" = 20' R1 --REVISED PUMP CHAMBER R2 --ADD SURVEYORS STAMP