HomeMy WebLinkAboutReview Checklist �--��"� � .
� TOWN OF YARMOUTH ����� �
SEWAGE PLAN REVIEW CHECKLIST ''���
�
Zone of Contribution: In� Out_�Acr�g
Location: A.M._��,� Lot -
� �� Commercial: Residential:
Street: �
Village: li' Floor Plan: " #Bedrooms:
Owner: Installer: �
Address: Phone: `
Phone:
Builder: Engineer: �
Address: Phone: �7 " �`
Phone: �-��/,,,��'1/�'� �� � ''`'� � , /,
���
A � S NO
l.Re uired# of copies received
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturall occurrin ervious material,above water ta.ble �--'�"
4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic com onents V�'•�
6. Benchmark indica.ted and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.: �--�'"
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands V�'•�
10.Leaching minimum 150 ft from drinkin we1U25 ft irri ation well Var.: -
1 l.Tank/leachin minimum 10 ft from roperty line Var.:
�
12. S stem meets all other setback r uirements Var.:
13.Uses adjustment for maximum hi groundwater Var.: �
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons) or 5'removal �-�
16.Pro osed contours are suitable !
17. S stem meets slo e r uirements-min. 1/8", '/4" eferred L-�`
18. System meets breakout r uirements PVC liner: Wall: � _ `
19. Specified tee sizes are ro er, gas baffle on outlet tee ,
20. Sewa e is under 10,000 d for arcel L��'
21.No garba e dis osal `'� �
22. S stem ad uatel sized for its intended use �o '
23.Minimum 6"stone or com acted below tank and dbox
24.Manhole covers within 6"of ade, um chamber cover to ade v`'�
25.Ins ection ort on lastic chambers/leach field
26.Electrical ermit for um chamber/S arate meter for du lexes •�A
27,pum system-2" line,wee hole,check valve,tee in dbo� ump size j
28. Septic tank/pum chamber to be factory waterproofed
i 29.Vent rovided if leaching below 3 feet,under driveway/parkin ,
i 30.Buoyancy calculations for tank/pump chamber
31.En ` eer to ins ect and cert' soils: � wall: commerc' L•
32.En ' eer/Registered Sanitarian and Land Surveyor stam s/si ature L ' �
33.H-201oadin is subject to vehicular traffic, oundwater ,
� 34.Title V A lication and ermit fee, insta.11er si ture �� ?� � � � �'`�
35.Foundaxion footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction r uired max. #bedrooms: max. flow: d
37.Check area lots for groundwater/Label oundwater in Assessor's Ma
6/03/03
' Plan reviewed by:
i
i