HomeMy WebLinkAbout2017 Feb 03, 07 - Emails r
vonHone, Amy .
From: Robert Crowell <crowelleng@gmail.com>
Sent: Friday, February 03, 2017 11:47 AM
To: vonHone, Amy
Subject: 330 long pond rd Septic
Attachments: 330 LONG POND SEPTIC.PDF i
�Y�
See attached septic design.
I will give more details on pump design . �
I will use a 26 inch diameter concrete manhole with a grinder pump per our discussion. The pdf shows the force
main going to the dbox; change that, going to ST.
Thank you in advance
I sent this at 9:30 this am. It bounced back...I am horrified....Hope you can give it a quick once over. I will make
my changes and have someone bring 4 copies to youtr office on Monday. I am leaving At 4 am tomorrow for
vacation
Please give me a call '
�
Bob Crowell, P.E. j
774-283-0443
i
,
i
,
I
i
i 1
l
�
�
. i
vonHone, Amy _ , '
From: vonHone, Amy �
Sent: Thursday, February 09, 2017 11:34 AM
To: 'Robert Crowell'
Cc: Grant, Kelly; Murphy, Bruce
Subject: RE: 330 long pond rd Septic
Attachments: 330 LONG POND DRIVE.tif; Septic Review Standard Conditions 2017.pdf
Bob-
I apologize for the delay. I have attached a copy of the plan that has been marked up for your review and
revisions when you are back from vacation.
1. Show work limit line in rear of house for conservation purposes. The septic permit will be issued with
the attached conservation guide.
2. Add notes to pump chamber:
a. Electrical permit required
b. Provide buoyancy calcs.
c. Waterproof at factory '
d. Provide gallons capacity since we are technically pumping for 2 bedroom in basement—must
provide 220 gal emergency storage
e. Show the pump chamber pumping to the septic tank (as you noted below) and change the
profile schematic to also show tank instead of dbox
3. Provide PLS stamp on plan (local regulation requirement) or provide copy of certified plot plan with PLS
stamp referenced
I will be unavailable 2/10—2/26, however, Bruce Murphy, Health Director, is available if there are any
questions. I hope you are enjoying your vacation.
,'
Thank you, Amy
Amy L.von Hone, R.S., C.H.O. ,
Assistant Health Director .
Yarmouth Health Department '
�
From: Robert Crowell [mailto:crowelleng�u,gmail.com] •
Sent: Friday, February 03, 2017 11:47 AM
To: vonHone,Amy
Subject: 330 long pond rd Septic
�Y�
� See attached septic design.
� I will give more details on pump design .
I will use a 26 inch diameter concrete manhole with a grinder pump per our discussion. The pdf shows the force
I main going to the dbox; change that, going to ST.
Thank you in advance
� 1
I sent this at 9:30 this am. It bounced back...I am horrified....Hope you can give it a quick once over. I will make
my changes and have someone bring 4 copies to youtr office on Monday. I am leaving At 4 am tomorrow for .
vacation
Please give me a call
Bob Crowell,P.E.
774-283-0443
.
�
�
I
i
I
I
I 2
;
a