Loading...
HomeMy WebLinkAbout2013 Oct 22 - Memo from Infiltrators Systsms Inc, � t INFILTRAT�JR� syst�ms in�. M E M O R A N D U M DATE: October 22, 2013 TO: Regulators, Designers, Distributors and Contractors RE: Chamber Load Ratings Infiltrator Systems Inc. (ISI) manufactures and warrants Infiltrator/Quick4�brand chambers and the TM ' TM tructuralloadin r . Please note the followin chamber s g ARC Biodiffuser chambe s g / recommendations: • H-10 Chambers: 16,000 Ib/axle load rating with a minimum of 12" of compacted soil cover and installed per installation instructions. Recommended for non-traffic installations. . - 4 ft maximum cover on bed instaliations and 8 ft maximum cover on trenches. • HD Chambers: 16,000 Ib/axle load rating with a minimum of 12" of compacted soil cover and installed per installation instructions. Recommended for residential driveway installations but not applicable for commercial traffic installations. - 5 ft maximum cover on bed installations and 8 ft maximum cover on trenches. ' • H-20 Chambers:32,000 Ib/axle load rating with a minimum of 18" of compacted soil cover and installed per installation instructions.Suitable for commercial traffic loading. - 8 ft maximum cover on bed and trench installations. Ali chambers may be installed with a minimum of b" of compacted soil cover installed per installation : instructions for a load rating of 4,000 Ib/axle. All chambers with shallow (at least 6" but less than 12") soii cover are recommended for non-traffic installations. Please contact me if I can be of further assistance, Best Regards, Dennis •C/ � � � 1 Dennis F. Hallahan, P.E. � Technical Director Infiltrator Systems Inc. � 6 Business Park Road•P.O.Box 768•Old Saybrook,CT 06475•Phone 860.577.7000•Fax 860.577.7001•www.infiltratorsystems.com