Loading...
HomeMy WebLinkAboutReview Checklist i r�ZZ -1 � TOWN OF YARMOUTFI ., SEWAGE PLAN REVIEW CHECKLIST � Location: A.M. � � Lot � � Zone of Contribution: In Out �ge s Commercial: Residentia� Street: � � Village: Floor Plan: � #Bedrooms: � ',, Owner: Installer: �.� �� I Address: Phone: + ', Phone: � �'� � ���'"`�' Builder: Engineer: �� i Address: Phone: ��7 - � - � Phone: " , ��. � N/A YES NO 1.Re uired#of co ies received ✓ 2. Date of soils exam and ercolation test not older than 2 yea.rs �--� 3. 4-5 ft of naturall occurrin ervious material, above water table '�/� 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: L./ j 6.Benchmark indicated and shown-NGVD if near wetlands ✓ ' 7. S tic tank minimum 10 ft from foundation, deck Var.: , 8.Leaching minimum 20 ft full, 15 ft cra.wl, 10 ft slab Vaz.: 9.Leaching minimum 100 ft from wetlands Var.: --�- I 10.Leaching minimum 150 ft from drinkin welU25 ft irri ation well Var.: �-''"�� 11.Tank/leachin minimum 10 ft from ro line Vaz.: t../ 12. S stem meets all other setback r uirements Var.: 13.Uses ad'ustment for maximum hi oundwater Var.: 14.Leachin set 4-5 ft above adj.water or bottom of test hole Var.: ' 15. S stem not in to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable ✓ 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. S stem meets breakout r uirements PVC liner: Wall: �-- 19. S ecified tee sizes are ro er, gas ba.ffle on outlet tee ✓ 20. Sewage is under 10,000 d for arcel `-�� !i 21.No garbage dis osal �� �' " '22. S stem ad uatel sized for its intended use �---� - : 23.Minimum 6"stone or com acted below tank and dbox , 24.Manhole covers within 6"of ade, um chamber cover to ade L� I, � 25.Ins ection ort on lastic chambers/leach field (;._� 26. Electrical ermit for um chamber/S a.rate meter for du lexes " 27.Pum s stem-2" line,weep hole,check valve,tee in dbox, um size ----- , 28. S tic tank/ um chamber to be facto wat roofed 29.Vent rovided if leachin below 3 feet, under drivewa / arkin 30. Buo ancy calculations for ta.nk/ um chamber ! 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.En ' eer/Re 'stered Sanitarian and Land Surve or stam s/si ture - 33.H-20 loadin is sub'ect to vehicular traffic, oundwater � 34.Title V A lication and ermit fee,installer si ature 35.Foundation footin min. 2 feet above ad'usted ground water for new house �=-� 36.Deed Restriction r uired max. #bedrooms: �-max. flow: �,._ ' d 37.Check area lots for oundwater/Label oundwater in Assessor's Ma ; Plan reviewed by: '� sro3�o3