HomeMy WebLinkAboutEngineered Plan - 2009FOUNDATION SYSTEM PROFILE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE D. EL. 23.1' MINIMUM 75' OF COVER OVER PRECAST PRECAST H-10 RISERS (TYP.) 2'0 20.8' 4� EXISTING 10. 1000 GAL H-10 14" TEE SEPTIC TANK TEE 19.4' (RE -USE)** oo 0000a GAS BAFFLE ::` EXIST. LEGEND 4' LIQ. LEVEL (ACME OR EQUAL) 19.18' 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 CLASS I SOILS TEST HOLE 2� SLOPE OF GROUND_ c_Q UTILITY POLE �cllll__- FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING (NOT TO SCALE) 4"OSCH40 PVC PIPES LEVEL 1ST 2' 6" MIN. SUMP V 19.01', 2' 19.01 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE 2% SLOPE REQUIRE OVER SYSTEM 2" DOUBLE WAR6 PEASTONE OR GEOTEXTILEI FABRIC H-20 3050 INFILTRATORS 19.5' 17.01' 3/4" TO 1 1/2" DOUBLE WASHED STONE / 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) OVERALL DIMENSIONS TO OUTSIDE OF STONE: 30.4' X 10.25' (-!-V. SLOPE) 11.6' BOTTOM TH-1 NO GROUNDWATER FOUND SEPTIC TANK 22' D' BOX 2' LEACHING FACILITY w *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE. TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, SE GARBAGE DISPOSER IS NOT ALLOWED WITNESS: AMY VON HONE, RS DATE: JUNE 23, 2009 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS LEACHING: ELEV. 1 Q opt 22.6' TOTAL: 473 S.F. 350 GPD FILL 9„ USE (4) 3050 INFILTRATORS, l WITH 1' STONE AT ENDS AND 3' AT SIDES A L LS - 1OYR 4/2 It 11 B LS 28„ 1OYR 5/6 20.3' PERC EO FMS 1OYR 7/4 132" I 111.6' NO GROUNDWATER ENCOUNTERED 09-147 �f 20.4 ,,+-20.0 / 8.7 SO \ 20.4 p0 + 20.0 6 PAVED t wS \ DRIVE. \ °O / \ 22,8 -119,4 + 8 o 22.9 BENCHMARK: USE CONIC PATIO CORNER AT ELEV. 22.7' C� y9ti 2.7 �y AN 2 �- to NOTES 1.. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT UNE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. T Buck /s/o�d e� o n 5ro L us q ca °� 0 ° s��e4 0°� Morn' �o �cwsf. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE OF ALL UNDERGROUND OVERHEAD U11UTI SATION PRIOR TO COMMENCEMENT OF LOCUS MAP WORK. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 49 PARCEL 212 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOT 53 10,000 SF GARAGE \ (SLAB) 22.3 EXIST. DWELL. TOP FNDN. = 23.1' 400 22.7 Q P2Y GONG 22.2 + 1100 22,8 EXIST. ST °o. + 22.. 2. 22.4 O + 22.4 + 22.5 22.6 GS, FF- + 221 OSP 'i 3.2 +/ o� / X2.6 o\ Scole:1"= 20' 0 10 20 30 40 50 FEET 22.9 22,6 22.7 2.7 PLS SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW _SEPTIC TANK_: -330-GPD _ 2 = 660 RE -USE EXISTING 1000 GAL. SEPTIC TANK** LEACHING: SIDES: 2 (30.4 +10.25) 2 (.74) = 120 GPD BOTTOM 30.4 x 10.25 (.74) = 230 GPD TOTAL: 473 S.F. 350 GPD s USE (4) 3050 INFILTRATORS, l WITH 1' STONE AT ENDS AND 3' AT SIDES L - �q MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 11 MERGANSER LANE WEST YARMOUTH PREPARED FOR EST. OF P. L'ANTIGUA JUNE 23, 2009 off 508-362-4541 I fax 508-362-9880 downcope.com 0OW17 cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 09-147.DWG(SBO)