HomeMy WebLinkAboutBLD-17-5693SEE VALVE DETAIL 4- — - 2" WATER SERVICE _.---SPARE HEAD CABINET 1ofTO_� 0 SYSTEM 1 1/4" VICTAULIC RISER MANIFOLD / FLOW SWITCH, PRESSURE GAUGE, TEST AND DRAIN VALVE Litu 1 1/4" BUTTERBALL ® i VALVES W/ TAMPER SWITCHES TEST & DRAIN VALVE//TO DOMESTIC WATER METER 3/4" DRAIN 0--'�2- WATER PIPE T0/ SERVICE EXTERIOR) 11/4' AMES ODEL 20008—FP DOUBLE CHECK VALVE Valve Detail NOT TO SCALE SITE PLAN NOT TO SCALE j, LO I FLOW HYDRANT GAUGE HYDRANT ELEV: 7' 21 TOTAL SPRINKLERS MAX RESIDENTIAL HEAD SPACING: 16'x16' DRY SIDEWALLS AT UNHEATED CLOSET V-0" MINIMUM LENGTH HYDRAULIC REMOTE AREA #1 D. FPE STAMP A.H.J. LOCAL FIRE DEPT./F.P.E. SPRINKLER SYMBOLS PIPE TYPES t7u., 0 'N WA, SYM CNT NAME FINISH TEMP K -FAC NPT MFG. MODEL# ESCU IDEN# Q 10 RES. PENDENT WHITE 155 4.90 1/2" RELIABLE 171RES WHITE R3516 d 9 RES. SIDEWALL WHITE 155 4.40 1/2" RELIABLE FIRES WHITE R3531 1001 2 DRY SIDEWALL WHITE 155 4.40 1" RELIABLE F3RES44 WHITE RA5231 21 TOTAL SPRINKLERS MAX RESIDENTIAL HEAD SPACING: 16'x16' DRY SIDEWALLS AT UNHEATED CLOSET V-0" MINIMUM LENGTH HYDRAULIC REMOTE AREA #1 D. FPE STAMP A.H.J. LOCAL FIRE DEPT./F.P.E. DESIGN STD. N.F.P.A. 13D (2013 EDITION) PIPE TYPES t7u., 0 'N WA, MAINS CPVC co °''03 BRANCHES CPVC SPRINKLER ORIFICE K= 4.40 AREA LOCATION 2nd FLOOR LIVING # OF FLOWING SPRINKLERS 2 NOT TO SCALE DENSITY 0.05 G.P.M./SQ.FT 256 REMOTE AREA TWO SPRINKLERS SQ.FT. DEMAND AT SOURCE CONNECTION �f FLOW 32 G.P.M. PRESSURE 43.0 P.S.I. OUTSIDE HOSE STREAM _(INCLUDED) 0 G.P.M. AVAILABLE PRESSURE OF 75.0 psi EXCEEDS THE REQUIRED PRESSURE OF 43.0 psi. THIS IS A SAFETY MARGIN OF 32.0 psi OR 439 OF THE SUPPLY WATER FLOW TEST DATE: 4/3/17 STATIC: 75 PSI RESIDUAL: 70 PSI FLOW: 1250 GPM BY: MASS FIRE PROTECTION Jlr/'1LC 1/Y - I 'V 3 GENERAL NOTES 1. PROJECT IS A NEW 2 STORY SINGLE FAMILY HOME (NO BASEMENT). TYPICAL WOOD CONSTRUCTION. 2965 TOTAL SQUARE FEET (BOTH FLOORS INCLUDED). 2. FIRE SPRINKLER SYSTEM SHALL BE INSTALLED THROUGHOUT BUILDING. WET SPRINKLER SYSTEM SHALL BE PROVIDED. 3. SPRINKLER SYSTEM IS DESIGNED IN ACCORDANCE WITH NFPA 13D (2013) "INSTALLATION OF SPRINKLER SYSTEMS IN ONE & TWO FAMILY DWELLINGS". 4. OWNER TO PROVIDE ADEQUATE HEAT THROUGHOUT TO AVOID PIPES FREEZING. MAINTAIN TEMPERATURE ABOVE 407. 5. ALL WORK AND MATERIALS WILL BE IN ACCORDANCE WITH NFPA 13D STANDARD. 6. ALL SPRINKLER PIPING SHALL BE BLAZEMASTER CPVC JOINED BY COMPATIBLE CPVC FITTINGS. CPVC PIPE SHALL BE INSTALLED PER MANUFACTURER LISTING. EXCEPTION: VALVE ROOM PIPING SHALL BE BLACK STEEL PIPE THREADED OR GROOVED. 7. INSTALLING PENDENT AND SIDEWALL SPRINKLERS THROUGHOUT LIVING SPACE. 8. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS WHICH DO NOT EXCEED 55 SQUARE FEET. 9. SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS WHICH DO NOT EXCEED 24 SQUARE FEET AND HAVE A LEAST DIMENSION WHICH DOES NOT EXCEED 3 FEET. 10. SPRINKLERS ARE NOT REQUIRED IN ATTICS AND CONCEALED SPACES NOT INTENDED FOR LIVING, STORAGE, AND CONTAIN NO FUEL FIRED EQUIPMENT IN ACCORDANCE WITH NFPA 13D. 11. SPRINKLERS ARE NOT REQUIRED IN GARAGES. 12. SPRINKLERS ARE NOT REQUIRED AT COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS. 13. ALL ELECTRICAL WIRING FOR ALARM DEVICES SHALL BE PROVIDED BY OTHERS. 14. ALL CPVC PIPING SHALL BE CONCEALED IN WALLS AND JOIST SPACE. IF THIS IS NOT POSSIBLE, SOFFITS SHALL BE PROVIDED BY OTHERS. CPVC PIPE STRAP O o CPVC PIPE HEX HEAD SELF TAPPING SCREW _1-1n DOUBLE FASTENER CPVC PIPE STRAP HANGER APPLICATION O RESTRAINERAPPLICATION CPVC PIPE / O HEX HEAD SELF TAPPING SCREW` T SINGLE FASTENER CPVC PIPE STRAP WOOD BEAM --------SAMMY SIDEWINDER �3/8" ALL THREAD ROD SWIVEL RING HANGER 1P41 2S' Q) U r W 00 Q) Cit o Q) u cd p 0 O Co � Scott Henderson D. FPE STAMP rR� 0140-01*0*0ritf t7u., 0 'N WA, -1 co °''03 2017.04. C NOT TO SCALE J ` 'sL Q 2S' Q) U r W 00 Q) Cit o Q) u cd p 0 O Co � Scott Henderson D. FPE STAMP HANGER DETAIL w�x co °''03 2017.04. C NOT TO SCALE J ` 'sL Q 10:49-026 �f cf) I 4) C z 1001 4_ � LL .69 z I- 9 Ofa N Rt O � O 00 UN - o0 Ja w O co d - O O Lid 0 0 U a� 0 a w V3 A 0 m n Q z C I T u- 0 Cn 0 L 0Co