Loading...
HomeMy WebLinkAbout2014 Nov 24 � J.M. O'Reilly & Associates, Inc. LETTER OF Engineering&Land Surveying Services 1573 Main Street,2nd Floor,P.O.Box 1773 T Brewster,MA 02631 ° (508)896-6601 aEC u � 2��4 Fax(508)896-6602 HEALTH DEPT. TO: DATE: JOB NUMBER: Town of Yarmouth 11/24/2014 6611AW Board of Health 1146 Route 28 REGARDING: South Yarmouth, MA 02664-4492 � ! Locus: 94 Iroquois Bivd, Yarmouth ; Shipping Method: Regular Mail ✓Q Federal Express � Certified Mail � UPS � Priority Mail � Pick Up � Express Mail � Hand Deliver � i COPIES DATE DESCRIPTION Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system For review and comment: � For approval: � As Requested: � For your use: � REMARKS: cc: John M. O'Reilly, P.E., P.L.S. Keith E. Fernandes, P.E. Client Oakson, Inc. From: els/KEF If enclosures are not as noted,kindly notify us at once � , ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address.: 94 Iroquios Blvd,Yarmouth Date: 11/21/2014 Homeowner: Tom Sheehan i Operator: Keith E. Fernandes, P.E., WWTO 4M-Full #13240 i ]Ob #: 6611AW HISTORICAL DATA and CURRENT READINGS_ � Previous flow meter reading: �3640 Design flow: 330 Date of last visit: 10/25/2013 Current flow meter reading: 9394o Calculated water usage: 51 GPD � Start-up dose rate Current dose rate � ZONE 1: 2�� GPM 2�2 GPM ZONE 2: I ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NO p Comments: � B. Air release valves: erosion YES❑ NOD . leakage/spraying YES❑✓ NO❑ COII'11712f1tS: Release valve broken.Replaced at time of inspection. PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YES� NO❑ � Comments B. Alarm float working YES� NO❑ Comments: C. Solids or scum present YES� NO� Comments: CONTROL PANEL A. Switches in AUTO position YESD NO❑ Comments: ` • _ � ' 6. Peak Level (ight on YES❑ NO❑✓ : Comments: i � C. Power and Run lights on (microprocessor) YES❑✓ NO❑ Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YES�✓ NO❑ Comments: ^ B. Zones 1-4 (one at a time): flow meter running YES�✓ NO❑ � dose rate correct YES❑✓ NO❑ flush rate > dose rate YES�✓ NO❑ Comments: C. Disc filter back flushing: working properly YESD✓ NO❑ ' Comments: D. Discfilter inspection: excessive residue YES�✓ NO❑ cleaning required YES�✓ NO� Comments: E. Switches returned to AUTO position YES�✓ NO❑ Comments: F. RESET/CYCLE START: functioning properly YES❑✓ NO ❑ Comments: � G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO�✓ � Comments: i i � � SEPTIC and/or PRE-TREATMENT TANKS *No cover at grade for access to inspect. A. Examine and clean effluent filter: excessive residue YES❑ NO❑ Comments: B. Septic tank pumping recommended YES❑ NO ❑ 1. Sludge depth: 2. Scum depth: Comments: C. Service pre-treatment system YES❑ NO❑ Comments: Operator signatur License No.13240 Comments/Observations: Green air release valve covers missing and should be replaced.Homeowner notified.