SEWAGE PLAN REVIEW CHECKLIST /�"'� `�,j
� Location: A.M.� Lot� Zone of Contribution: In_(�6�t_ Acreage����
�� • Commercial: ResidentiaL• �
Street:
Village: Floor Plan: E #Bedrooms: `�
;� ,/�� �
tOwner: ������ /�'j �/GT'��2� Installer: �
Address: � Phone: -
Phone: • � �
. ,
Builder: Engineer: `l� G���%
Address: Phone: �0 --' -'
Phone: ��' ' .' / � �
G�
N/A S NO
l.Required#of co ies received
2.Date of soils exam and percolation test not older than 2 years L,�'
3.4-5 ft of naturall occurrin ervious material, above water table C_-�
4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.: ;,/�
8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: •
9.Leaching minimum 100 ft from wetlands Var.:
10.Leachin minimum 150 ft from drinkin we1U25 ft irrigation well Var.:
1 l.Tank/leaching minimum 10 ft from ro erry line Var.:
12.S stem meets all other setback r uirements Var.:
13.Uses ad'ustment for maximum hi oundwater Var.: -
14.Leachin set 4-5 ft above adj.water or bottom of test hole Var.: �-�'
15. System not in top or subsoil(A,B horizons)or 5'removal L�
16.Proposed contours are suitable ��
17. S stem meets slo e r uirements-min. 1/8", '/4" referred t�
18. System meets breakout requirements PVC liner: all:
19. Specified tee sizes are proper, gas baffle on outlet tee
' 20. Sewage is under 10,000 gpd for arcel ' '
- 21.No garbage dis osal C�� �
22. S stem ade uatel sized for its intended use '
� 23.Minimum 6"stone or compacted below tank and dbox
� 24.Manhole covers within 6"of grade,pum cha.mber cover to grade
25.Inspection port on lastic chambers/leach field
26.Electrica.l ermit for um chamber/S arate meter for du lexes '
27.Pump system-2" line,weep hole,check valve,tee in dbox,pum size '
28. S tic tank/ um chamber to be factory wat roofed ��--� ',
29.Vent rovided if leachin below 3 feet, under driveway/ arking �-�' I
30.Buoyancy calculations for tank/pump chamber '
3l.En ' eer to ins ect and c ' soils: wall: commercial: '�
32.En ' eer/Registered Sanitarian and Land Surveyor stam s/signature '
33.H-201oading is sub'ect to vehicular traffic, groundwater I
34.Title V A lication and permit fee, installer si ature �'I
35.Foundation footing min. 2 feet above ad'usted ground water for new house •��
36.Deed Restriction r uired max. #bedrooms: max. flow: d
37.Check area lots for oundwater/Label oundwater in Assessor's Ma --1 i
Plan reviewed by: wo3�o3