Loading...
HomeMy WebLinkAboutSav-On - Site Planswarf oastu+a at atra=auoair�i .� ,Q GENERAL NOTES COM SM D. I. ISLANDS . tcx .rr. oonG �o _ tRssmn n. _ -- eaT ti v .e - THREE NEW 5' SX -25' PUMP DISLANDS RWITH AENEW SIXHOSE IV • • 2 X t N 29 �'X X-- t-i/r cww = •V q� j PRODUCT DISPENSER AND CRINDS {CARD READING SYSTEM) ON EACH ao . o -=,W Ir ed=�,•Ir COMPACTO a ISLAND. iD T 2. INSTALL ONE NEW 28' x 75' CANOPY OVER NEW PUMP ISLANDS AS Y m b' r o f ADQfr ooaE dt ' SHOWN. EXPAND® i N Dlla!ITEIIi ' PLANTER +�1 3. INSTALL NEW PUMP ISLAND MATTS AS SHOWN. NEW POSITIVE LIMITING C� COWA to xn•serne -� ! - BARRIERS TO BE INSTALLED AS SHOWN. �� BIND l 'I G- 4. FIRE SUPPRESSION SYSTEMS TO BE UPGRADED PER NFPA-30 • �j�-►--_ L REGULATIONS, PEMALL MANUFACTURERS SPECIFICATIONS AND THE EXIST t�CDiQIAL r MASSACHUSETTS STATE FIRE MARSHAL REGULATIONS. SEE FIRE S LIGHT !. POLE` a 1� SUPPRESSION PLAN. EXIST LMJMAI- �i�•" ° ! p 5. EXISTING UNDERGROUND GASOLINE STORAGE TANKS TO REMAIN .•—STYLE LIGHT ,. MX t. CONCRETE / PAVING DETAIL T ` ® UNCHANGED. �' �•-� w� 6. ALL EXISTING PAVING, DRAINAGE AND UTILITIES TO REMAIN ! Kar t :_., R-25 UNCHANGED, EXCEPT AS NOTED. N/F jam J. ® 25 NEW `.� � ; ..��}^ �7+._ RDSARID F 8! 3:.�:-r ( DRIVE WIDTH - _ 9`3'' '`=� t=om q( 7. ALL EXIST CURB CUTS AND LANDSCAPE PLANTERS TO REMAIN UNCHANGED, EXCEPT AS NOTED. j8 4C t y �\ r�: S. SURVEY DATA TAKEN FROM SURVEY PERFORMED BY GOLDEN LAND SURVEY, D /// lea t�A, S 1 ; C` ,.r;, INC., 96 JORDAN RD., PLYMOUTH MA; TITLED: PLAN OF LAND IN y .!l YARMOUTH/BARNSTABLE MA, #381 CAMP ST., BARNSTABLE COUNTY;, \ ��• 40 DATED: 3/8/93, PLAN GLS #93-033 AND FROM FIELD OBSERVATIONS � ' 2/93. V ` p� O 9. OWNER: SHELL OIL COMPANY 400 BLUE HILL DRIVE f ` •p9, fAESTWOOD, MA 02090 APPRCX LD"..ATMN ST MASS. !` - T- £)CTBT SEPTIC INSPEC71ON t 617) 461-4600 r TAMC I LEECH SIGN TO REMAIN 10. APPLICANT: DECKER & COMPANY, INC. AREA -�►' ` EXPANDED 33 PARR PLAZA PLANTER POSITIVE LIMITING BARRIER DETAIL IP,. 0. BOX XMA oi58 39 (413) 243-4083 11. SCOPE OF WORK LIMITED TO ISLAND, MATT, DISPENSER RENOVATION Ole AND INSTALLATION OF OVERHEAD CANOPY ONLY. 12• ZONE BUSINESS INFORMATION: BARNSTABLE / -'YARMOUTH VolB SINESS R25 V� �� f�G TV REQUIRED FRONT SETBACK 20' 30' c!%,M coo& PROPOSED FRONT SETBACK 22'-6" 21* -(EXIST SSTBISL ND .• �`�� USE COMMERCIAL RETAIL,.. REMOVE EXIST ISLAND ---�*C- %q�L r, �,�(VARIANCE IS REQUIRED FOR CANOPY ON YARMOUTH; `SIDE) ` EXIST COLONIAL is CON LEGAL DESCRIPTION: BOOK 1436 PAGE 043' Q� STYLE LIGHT >� POLE Y Q 7b = • V ASSESSORS MAP/LOT: 345/09'`. 108/N94. RJZ ,,� \ "'to �� a 0% \ 2 01-2 13. TOTAL LOT SIZE: 27,588 +/- SQ. FT. TOTAL LOT COVERAGE: TO REMAIN UNCHANGED UTILITIES RR Q�Q \ ?0 N NOTE: SQUARTHE EPO POSITIVE 3NG XARRI R TO ON 4 3 CONTINUOUS (j1 CROSS INTERCONNECTING GROOVES, EQUALLY SPACED ON MIN. �`� q ♦ �` REQUIRED WITH CPOSITIVE H 12' MAX. 4s CENTERS. THE OUTSIDE GROOVES TO BE AT UhtR G E N E R A_L, NOTE S <Z�i o ATTN.S a` LIMITING BARRIER OF HAZARD PROTECTION AREA AND THE POTI:NTU11. SPILL AREA �/ TO BE WITHIN THIS PROTECTION AREA. GROOVES MAY BE SAWC'UT 1. Contact and coordinate with all proper authorities to field •O� �`' QFFIC AREA O \ �T �MED�INTO CONCRETE MAT. GROOVES MUST BE KEPT CLFJW verify the exact locations, sizes pand depths of existing , ` �� l� utilities and proposed connections prior t o consfruction Where conflicts arise between existing utilities, proposed connections and/or other construction, the contractor shall ti P notify the owner's construction engineer prior to continuance of work. The contractor shall contact Dig -Safe 72 hours prior to construction excavation. The locations of existing STORAGE underground sanitary and piping shown are approximate, having N BIT• been plotted from best available information from the utility by • c$e SERVICE BAYS / company. 2. Field verify all existing and proposed invert elevations. \ / Notify owner's engineer of any discrepancies between field and 2,�0o sa FT. � o f �. EXPANDED plan information. N/F PHILIP GROSS FL. AREA CASTLEMAN PLANTER �~ EXIST BLDG. TO • • 1 3. Assure that all utility locations, size, material and REMAIN UNCHANGED tv / rllb •'9�- appurtenances are approved by the respective utility having jurisdiction. / EXIST CM -DNI / s' ,' •Y< ,,: / / INSTALL (3> NEW 5'X15 ( STYLE LIGHT L POLE - 4. Furnish and install all required boxes and sleeves for Sp — ISLANDS NEW 28'X%5 ` openings through concrete foundations, slabs, etc. for (3) COLUKN CANOPY electrical and plumbing, with the electrical and mechanical/plumbing • contractors regarding location, size and an other requirements so as to provide Y q proper openings for all services to buildings. \ • ��\ 5. Assure that electrical contractor furnish and install adequate y panels in required building(s) to accommodate all wiring and r'XIST DLh+GPSTER LQCATIONsC / _`` `\ , NEW DRAIN LINES FROM VQ y proper functioning of all items shown controls necessary for CANOPY ROOF DECK ! TIED on drawings. TO EXIST CATCH BASIN EXIST 64 SQ,FT. �. / b h 6. Insulate all water pipes within 5'-0" of finish grade. SHELL PECTIN GJ4RDS (TYP/� / ti 7. Consult with utility company regarding location of the utility pole and service entrance. / °) �/ • S. All underground electrical conduit shall be either rigid steel e EXISTING /�•.�� / \ conduit or intermediate steel conduit with number 12 n�inimum . V'Q TANK PADS �I�OC� • copper conductors for light fixture wiring. `SCC. 9. Provide seal fittings at each end of conduit runs for 0 EXIST CATCH BASIN TO submersible pumps, pole lights, dispensers, fire suppression /j REMOVE EXIST ISLAND BE CLEANED E� SERVICED system, and all other conduits as required by the National %i Electric Code. fes' PIPING TRENCH FOR • � PRODUCT SUPPLY & VAPOR �8, I �i;ti � 10. Submit a service request card to the electric company and O RECOVERY LINES t�' L. GRASS AREA verify the service location prior to any trenching or running �— of conduits. 4Q?—� C3. y �- _` / 0_ 11. Install and wire the relay cabinets for control of the Y O submersible pumps. The relay cabinets will be furnished by U Z Q Q Shell Oil Company. / W U (,DDD CiAI. 0 _J/ Lj 12. Furnish and install g g g w R � grounding bushings and round at all NEW BIT. CURBING c� w lights and signs. • O o tZ / DIST Ci1LONIA'- co !EXPANDED ;� EXIST COL.Dr�CAL / o c 1 STYLE LIGHT L POLE PLANTER N O- STYLE LIGHT 6 POLE �8� 2eV�(o!J Nnv.0.5 1393-.;°1-z4-93 1v �v�'IciN - 00 22L940 O 0 GRASS AREA s 0iI C o 120%ni pwp%a Isoml y o 0 o SITE PLAN fn ��rd" FOR t CAMP STREET ��' 381 CAMP STREET 381 WILLOW PUBLIC — 60' VIDE HYANN I S , MA YARMOUTH, MA DECKER & COMPANY SCALL, ' 1! V t v fI S3 PARK PICA /yam) By. tFE 141SS • - s trTNO 6+ MA r, E, eLuEPR.rt ,