Loading...
HomeMy WebLinkAboutEngineered Plan - 2007N/F N ARISAN Al WAYS nin SAFF PRInR Tn rnNSTRUCTInN--trni ITY I OrATIONS SHOWN INCOMPLETE .3' .DEEP IMPERVIOUS BARRIER --75 L.F. OF 40 MIL POLYETHYLENE ®13,72 (MILLER BREAKOUT**) A4 14. BENCH MARK -TOP MAG. NAIL SET TOP BARRIER=TOP x IN PAVEMENT=14.40 ASSIGNED UNITS=15.04,GRADE ABOVE BARRIER -=15.5 MIN ** BARRIER IS STIFF 8c OBTAINABLE FROM 15.814.11 \ CALL R.J. CADILLAC AND/OR MILLER -ENVIRONMENTAL HEALTH DEPARTMENT TO \ INSPECT REMOVAL PRIOR TO 508-697-3710. 15.3 \ \ PLACING SAND. 5.1 14.40 ... 9 \ BENCH MARK -TOP, BACK, CENTER N/F SEPTIC TANK=15.56 ASSIGNED `RODERIQUES �� ::ate ::.. .7\ e0o") x'15.7 14.8 4,6 \ \ 1 3.7 \ GRADE CHANGES ARE L:OT 86 1 :.{ �- PROPOSED,.AS SHOWN. N _`\: 4: • 1�3.9x 14,6 x\ :: 72920 %.F.� 15.1 6.2, 5` . \ VA 14,0 V. 14,6 C 15 6' ✓ 4,9 \ : 4.9 C \ 14.6 x26,3 p \ �/�\ 0 l � 14.58 14.7 co \ 5.9 ..: 6.�\ 'Dec oo TI•}\ 1 5,3\ 15,1 1),6 \ �0 5Q \ of N/F Gt0ya F� � /� / 15,63 BUCKLEY ��:: ...::::.. �' � 16,2 F �' � 15.74 16.4 x 16.1 16.4 BENCH MARK--S.W. CORNER OF BOTTOM STEP=16.26' ASSIGNED i' ><I 5.81 \ 16.3 .3�i \ 16.2 16.2 \ 15.9 7 16,8 ���/// 6X 25.85 H2O ROUND (4INSIDE DIAM.) BRDM PUMP CHAMBER DRILL 3/8" WEEP/VENT HOLE Place 4" inlet pipe 'KITCH BATH slmNc.RM. top 8" knockout 14.19 Quick Disconnect/ Invert Alarms 22 Union LVNG RM. BRDM` On -16" Check Valve Off 9" FLOOR PLAN P NOT TO SCALE 10.05 » LEGEND "Bottom- 6 STONE UNDER 41> TH 1 TEST MOLE LOCATION, .NUMBER V/ WATER LINE MARKINGS E OVERHEAD ELECTRIC WIRES (IF SHOWN) G GAS LINE MARKINGS x 9.5 x 15,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) �-6-� EXISTING CONTOUR g PROPOSED CONTOUR UTILITY POLE (IF SHOWN) ® EXISTING DRAINAGE CATCH BASIN x - FENCE (IF SHOWN, NOT ALL SHOWN) .0 TREE (IF SHOWN, NOT ALL SHOWN) JOB NO. Y07-,02 17.06 Top ,Found. Invert 15.14 Exist. PVC pipe TEST HOLE DATE: February 7, 2007 PERFORMED BY- Ron Cadillac, Soil Evaluator WITNESSED BY: Philip Renaud, Inspector PERC RATE: <5'-00"/inch (C layer) SOIL SURVEY(1993): Carver coarse sand GEOLOGIC MAP(1986): Harwich outwash plain :deposits Existing 6" cover S=3/4"./ft _ Existing Invert 14.52 1000 Gal. I Existing Septic Tank Invert 14.27 9 CULTEC CONTACTOR 100'S Existi12" Cover Use Gas Baffle Invert 14.56 Proposed 15.04 see detail Top Unit® filter cloth 4" .Inspection P Port Sanitary 6" I Bottom 10.0 Tee T 60' 70' 78' 1 Q8' 118" 160" Fill A layer 10yr 3/1 sandy loam perc_hea waTCr - . :B layer 7.5yr 3/3 sandy loam C layer 2.5y 5/4 vey fine loamy sand observed watLr- 110.8 r - i 0.8 10.0 6.8 6.0 2.5 Proposed Invert 14.73 ' NOTES WHITEHEAD.dwg BUCK ISLAND RD. 1. LOCUS IS A.M. 49, PARCEL 4. Proposed I -_ Kl-=10.0 2. ELEVATIONS SHOWN ARE . ASSIGNED. I I I, 3. ,LOCUS IS IN FLOOD ZONE ,B ON FIRMS :DATED .JULY :2, 3992 -,& .MUNE 17, 1986. I 10 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) m 5. MUNICIPAL WATER 1S AVAILABLE. LOTS WITHIN 100' . ARE ON TOWN WATER. s - 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. �o 0 7. INLET TEE TO PROJECT DOWN 13', OUTLET TEE DOWN 14". CIRCUIT RI 8. IF TWO OR MORE LINES,WATER. TEST D -BOX FOR EQUAL FLOW W o� s BEDROOMS: . D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. _ ___ Observed Water=6.0 9. DEPTH OF :COMPONENTS -NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. NOT T LEACH AREA COVERS: BUILD UP COVERS --1 TO GRADE OVER PUMP, 1 ON LEACHING. SCALE 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. LOCATION MAP 11. IF UNSUITABLE .°SOILS, OR SOILS . DIFFERING FROM .THE SOIL LOG .ARE FOUND, EXCAVATE 22'=6" BY 10'. LEACH AREA; AS SHOWN. USE 9 CULTEC H=10 CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 337.5 SF 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING 5.0 SF/LF X 7:5'/UNIT=37:5 S.F/UNIT MAINTENANCE OF PUMP: =PROVIDE UNION/DISCONNECT IN 2" PVC IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 13. PUMP AND "FILL ANY -EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, -BLOCK, AND STONE IN DESIGN CAPACITY: LEACH AREA, AND DISPOSE . OF AS .DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. 0 15.8 17.06 Top ,Found. Invert 15.14 Exist. PVC pipe TEST HOLE DATE: February 7, 2007 PERFORMED BY- Ron Cadillac, Soil Evaluator WITNESSED BY: Philip Renaud, Inspector PERC RATE: <5'-00"/inch (C layer) SOIL SURVEY(1993): Carver coarse sand GEOLOGIC MAP(1986): Harwich outwash plain :deposits Existing 6" cover S=3/4"./ft _ Existing Invert 14.52 1000 Gal. I Existing Septic Tank Invert 14.27 9 CULTEC CONTACTOR 100'S Existi12" Cover Use Gas Baffle Invert 14.56 Proposed 15.04 see detail Top Unit® filter cloth 4" .Inspection P Port Sanitary 6" I Bottom 10.0 Tee T 60' 70' 78' 1 Q8' 118" 160" Fill A layer 10yr 3/1 sandy loam perc_hea waTCr - . :B layer 7.5yr 3/3 sandy loam C layer 2.5y 5/4 vey fine loamy sand observed watLr- 110.8 r - i 0.8 10.0 6.8 6.0 2.5 Proposed Invert 14.73 Invert 14:50 6 Bottom PLACE IMPERVIOUS BARRIER, AS so 6 Stone or compact Proposed Proposed I -_ Kl-=10.0 II I I I, I I N I 6, I per waher I 10 { 4) 3 .I I - 36, EI.=8.0 REQUESTED:. for any future additions/renovations/alterations to WIRING INSPECTOR. _ rn 2.0 USGS Adjustment .1' (9' PROVIDED). ® 3. ALARM TO BE LOCATED IN HOUSE. <Using MASH29-Dec 2006. PROVIDED) DESIGN DATA 4. PUMP TO BE CAPABLE OF PASSING - _Zone A BEDROOMS: 2 _ ___ Observed Water=6.0 BY 1' (4' PROVIDED). GARBAGE GRINDER: No LEACH AREA - '-- - -- REQUIRED---CAPACIT=Y:-"------'-22 -SEE-MC-Dln9)-CE- RTIFIC-ATION--FOR-GENERAL-USE -REV.-7/24/06) -- -- - PROPOSED SEPTIC TANK: 1500 GAL. EXCAVATE 22'=6" BY 10'. LEACH AREA; AS SHOWN. USE 9 CULTEC H=10 EFFECTIVE LEACHING AREA: 337.5 SF CONTACTOR 100'S SET IN 3 ROWS 6' APART. LAY FILTER CLOTH OVER 5.0 SF/LF X 7:5'/UNIT=37:5 S.F/UNIT MAINTENANCE OF PUMP: =PROVIDE UNION/DISCONNECT IN 2" PVC CONTACTORS AND 'BACKFILL TO TOP OF UNITS WITH -CLEAN 'SAND FROM 9 UNITS X. 37.5 SF/UNIT=337:5 SF(EFFEC7IVE) . A GRAVEL PIT, OR VIRGIN C LAYER FROM SITE MAY BE USED IF IT CAN DESIGN CAPACITY: 249 GPD BE KEPT CLEAN AND FREE OF TOP AND SUBSOIL. [(337:5 SF) X .74 GPD/SF] FEB 1 3 2007 5' REMOVAL WITH BARRIER PUMP CHAMBER STORAGE CAPACITY. 220 GAL. DO 5' ALL AROUND REMOVAL DOWN' 9't TO VERY FINE LOAMY SAND. ALARM & PUMP NOTES DOSES PER DAY: > 4 PLACE IMPERVIOUS BARRIER, AS SHOWN, Permit valid for REPAIR OF SEPTIC SYSTEM 1. ALARM TO -BE WIRED -BY ELECTRICIAN ON ONLY, due to State and Local septic variances. SEPARATE CIRCUIT FROM PUMP. Board of Health review and approval is required 2. ELECTRICAL WORK TO BE INSPECTED BY MAXIMUM FEASIBLE COMPLIANCE APPROVALS REQUESTED:. for any future additions/renovations/alterations to WIRING INSPECTOR. 1. VARY LEACH AREA TO -PROPERTY LINE BY .1' (9' PROVIDED). sewage facilities and/or structures/dwelling. 3. ALARM TO BE LOCATED IN HOUSE. VARY LEACHING TO DWELLING BY 4'-7"(15'-5" PROVIDED) Yarmouth Health Department 4. PUMP TO BE CAPABLE OF PASSING 310 CMR 15.21.1. (1). 1-1/4" SOLIDS AND INSTALLED IN STRICT 2.. VARY SEPARATION TO HIGH GROUNDWATER BY 1' (4' PROVIDED). APPROVED CONFORMANCE WITH MANUFACTURER'S 310 CMR 15.212, ,7. •��K `� SPECIFICATIONS. 5. USE :MEYER SRM4, 4/10 HP .PUMP, OR d2Z -� EQUIVALENT. 6. TO PROVIDE FOR EASY AND SAFE - .�s N ane Date MAINTENANCE OF PUMP: =PROVIDE UNION/DISCONNECT IN 2" PVC @ LINE AT TOP PUMP CHAMBER SO PUMP CAN BE REMOVED FROM TOP OF TANK. FLOAT BRACKET AT COVER SO SITE PLAN FEB 1 3 2007 -RECOMMEND FLOATS CAN BE ADJUST./REPLACED FROM TOP. FOR HEALTH DEPT. THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE: RONALD S WH I TE H E A D P\NOFMgsSgO LOT 86 59 SWAN LAKE ROAD, WEST YARMOUTH, M.A. _ R". ILFEBRUARY 12, 2007 SCALE: 1''=20' HEALTH AGENT APPROVAL DATE RONALD J. CADI,LLAC, PLS, RS, P.C. PROFESSIONAL LAND. SURVEYOR & REGISTERED SANITARIAN. P.O. BOX 258 WEST YARMOUTH, MA. 02673 .(508) 775-9700 @2007 BY R.J. CADILLAC PAGE 1 OF 1