HomeMy WebLinkAboutBono Sunoco-Standard Fiberglass Piping Details2' 0 GALV. STL. - VENT RISER 2' UNISTRUT PIPE CLAMP I 2' BREATHER VENT ASSY. a0 (PRESSURE RELIEF VALVE, GASOLINE) NOTE: IF KERO OR DIESEL. 2' VAPOR VENT ITEM# 52 REQ'D. 2'95 GALV. STL. VENT RISER i 0 I , GRADE_ 2 - 2041 GALV. ONIPPLE (TYP) M l PLAN - VENT RISER 2' UNISTRUT 41 PIPE CLAMP 2' PIPE 15 CAP z Q - zo I to o1 to o! 2' PIPE SUPPORT 2-0 GALV. STL.ANNULAR SPACE VENT RISER 2' GALV. 180' sa RETURN BEND 200 GALV. STL. ANNULAR SPACE VENT RISER I I I II CONCRETE FOUNDATION (FOR DETAILS SEE I I I I I DWG. 4-501, DETAIL 18) II I i II I I I I I I I I I I I I I I I I I I I I I I I I 3 - 2'0 G.I. 90' ELBOW 12 (TYP) 2.0 FRP ADAPTER BELL X NPT MALE 37 (TYP) 2'0 FRP VENT PIPE NOTE; 2" VENT LINE W/VENT VALVE (STAN3ARD) OMIT VENT VALVE & INSTALL 3' VENT LINE IN AREAS WHERE TRANSPORTS ARE NOT EQUIPPED FOR VAPOR RECOVERY I i 37 2'0 FRP ADAPTER BELL X NPT MALE 2' X 250" UNION 9� F_ 2- 2'0 GALV. 90' ELBOW O L_ 2-0 FRP VAPOR LINE r 4'X 2' C.S. BUSHING I6 SLOPE TO MANIFOLD �8 2 - 2'0 GALV. CLOSE NIPPLE MANWAY COVER 4' NPT COUPLING, BY TANK MFG, (C.SJ DETAIL 'J' VAPOR CONNECTION AT UNLEADED TANK (SEE DWG. NO. 3-413 FOR LEADED TANK) i i D c 2- 3' G.I. 90' ELGOW - 13 3' UNION O4s 3' 0 FRP ADAPTER 14 BELL X NPT MALE 3%0 FRP DRY BREAK LINE SLOPE UP TO DRY BREAK Q TANK 3 - 3' GALV. NIPPLE o j 3 - 2' GALV. NIPPLE- 0 IPPLE O s 2' GALV. UNION O 9 I I 2-2' GALV. 90' ELBOW I2 2' FRP VAPOR LINE SLOPE DOWN TO TANK (TYP.) THIS DRAWING IS AND SHALL REMAIN THE PROPERTY OF SUN REFINING AND MARKETING COMPANY. USE, REPRODUCTION OR ,ALTERATION OF THIS DRAWING WITHOUT THE EXPRESSED WRITTEN PERMISSION OF SUN REFINING AND MARKETING COMPANY IS PROHIBITED. 3' FRP VAPOR RETUNR LINE - MAX RUN TO DRYBREAK CONNECTION SHALL NOT EXCEED 100 FT. RUN AS DIRECT AS POSSIBEL USING A MINIMUM NUMBER OF PIPE ELBOWS (4' 0 SHALL NOT EXCEED 150') 3' DRYBREAK LINE MUST SLOPE DOWN TO MANIFOLD DRYBREAK CONNECTTION (SEE DETAIL 'L') FILL - SPILL CONTAINMENT (SEE DETAIL 3) VENT M.H. (SEE DETAILS 3 & '0') FUTURE ELECTRONIC GAUGE M.H. (SEE DETAIL 2) MANUAL GAUGE (SEE DETAIL 2) (SEE DETIAIL BLE 2 &MPH') 6' NPT FITTING (SEE DETAIL 1) ISOMETRIC OF MANIFOLD SYSTEM SHOWING PIPING AT UNDERGROUND TANK ARRANGEMENT (GASOLINE) (SEE DWG. 3-413 FOR DETAILS) FUTURE ELECTRONIC GAUGE WELL (SEE DWG. 3-413, DET. 2) RED JACKET LEAK DETECTOR MODEL #116-017 r 2' X 250' UNION i 2 - 2'0 GALV. O THREADED NIPPLE B 2'0 GALV. 90' ELBOW 12 2'0 FRP SPIGOT X NPT MALE MANWAY LID �J 280 FRP ADAPTOR 63 BELL X NPT FEMALE O MANUAL GAUGE SWIVEL END 2'X 30' FLEXIBLE CONNECTOR s2 2-0 FRP PIPE Z 2'41 FRP ADAPTER BELL X NPT FEMALE s3 DETAIL 'H' 36 SUBMERSIBLE PUMP NOTE: IF DOUBLE WALL PIPE (SECONDARY CONTAINMENT) IS REQUIRED SEE DWG. 3-419 FOR DETAILS VENT LINE CONNECTION 13'X 40' MANHOLE as D v a , D , 3' GALV. PIPE RISERS (TYP.) V i J I I I I I NOTE: 3' PIPE PLUG 42 3' GALV. NIPPLE O 7 0 0 li NOTE: 3"X 2' GALV. ENATE CONNECTION FOR REO.ELBOW VAPOR LINE IF GRADE S REQUIRE USE (SHALLOW COVER) LEADED & UNLEADED V/R VALVES, X2'41 FRP ADAPTER SEE DETAIL '"J' (TYP.) BELL X NPT MALE 37 DETAIL 'K' VAPOR RECOVERY MANIFOLD - -- 2' GALV. STEEL VENT LINE (STANDARD) NOTE: 3' VENT LINE IN AREAS WHERE MANIFOLD IS INSTALLED & TRANSPORTS ARE NOT EQUIPMENT FOR VAPOR RECOVERY 3 - 2'$ G.I. 90' ELBOWS (SEE VENT RISER DETAIL VAPOR RECOVERY MANIFOLD THIS SHEET) (SEE DETAIL 'K') 3' UNION 3' X 2' REDUCING ELBOW ANNULAR SPACE VENT LINE 2' VAPOR LINES MUST SLOPE UP TO MANIFOLD 2' VAPOR LINE MAX. RUN TO MANIFOLD NOT TO EXCEED 25'(3'0 SHALL NOT EXCEED 1001 ELECTRONIC MONITOR WELL - ANNULAR SPACE VENT (SEE DETAIL 4) POR LINE .E DETAIL 'J' & ALT. DETAIL 3A) ^ L 2-5/810 EXTRACTION BAR/ TAPERED VALVE SEAT S THREADS PER INCH 6 2e" VALVE SEAT DRAIN .� HOLE O 4-3/16'S� PRESS RELIEF HOLES 1/16' fd (ESSURE RELIEF )LE eco rfm ori, K ri v FLOAT ASSEMBLY 1 2.40' 0 2.40-0 ELEVATION ELEVATION DETAIL 'N' EVVR 30 LEADED VALE EVR 31 UNLEADED VALVE SCALE: HALF SIZE SCALE: HALF SIZE (FURNISHED BY SUN REFINING & MARKETING) 2s RD -12 MANHOLE 3' TOGGLE 29 CONCRETE MAT -7 r- 3' DRY BREAK 2a •,�� . • •. - 2' MIN. - 4' MAX. 2 - 3'0 GALV. NIPPLE O r 1 NE PIPERISERT BREAK I ! SLOPE DOWN TO MANIFOLD � 3'0 FRP ADAPTER BELL X NPT MALE 3-3' sv GALV. 90' ELBOW as 13 DETAIL 'L' CRY FREAK PIPING AND CONNECTION AT TAMC MANHOLE 2' FRP VENT LINE SLOPE UP TO VENT 2'0 FRP ADAPTER BELL X NPT MALE 37 3 - 2'0 GALV. 90' ELBOW? 12 C,[ U 2 - 2'0 GALV. NIPPLE 0 3' X 2' GALV. REDUCER la 2 - 3' GALV, NIPPLE O 7 1• 3' UNION PLAN - VENT LINE AT VAPOR RECOVERY MANIFOLD FIBERGLASS PIPING 1.0 SCOPE • WHEN FRP PIPE IS SCREWED INTO METALLIC FITTINGS REMOVE ANY BURRS FROM THE STEEL SUN STANDARDS CALL FOR ALL NEW OR REPLACEMENT WHICH MAY CUT INTO THE FIBERGLASS THREADS. UNDERGROUND PRODUCT PIPING TO BE OF APPROVED THREADED JOINTS, FIBERGLASS TO STEEL FIBERGLASS REINFORCED PLASTIC (FRP)DESIGN, UNLESS SHALL MEET ALL AMERICAN NATIONAL TAKER A WRITTEN EXCEPTION IS OBTAINED FROM THE MANAGER SCREW THREAD STANDARDS. ALL SUCH JOINTS TO OF ENGINEERING AND MAINTENANCE. THIS STANDARD BE SEALED WITH A HIGH QUALITY, NON -SOL VENT COVERS FRP PIPE AND THE INSTALLATION OF FRP CONTAINING TEFLON BASED THREAD SEALING PRODUCT PIPING. COMPOUND TO BE U.L. LISTED FOR USE IN GASOLINE SERVICE. JOINTS TO BE SEALED WITH 2.0 FRP PIPE SPECIFICATIONS 'LA -CO LOC'HIGH PERFORMANCE PIPE SEALANT WITH TEFLON, GASOILA SOFT SET W/TEFLON, 2.1 GLASS FIBER REINFORCED EPDXY PIPE SYSTEM SHALL BE RECTDRSEAL HEAVY DUTY 100 VIRGIN W/TEFLON OR IN COMPLIANCE WITH ASTM SPECIFICATION D-2310 JOMAR HEAVY DUTY W/TEFLON APPLIED (STANDARD CLASSIFICATION FOR MACHINE MADE TO MALE THREADS. REINFORCED THERMOSETTING RESIN PIPE, RTRP, D-2936' ' (STANDARD CLASSIFICATION FOR FILAMENT WOUND RTRP) START THE THREAD BY HAND AND MAKE UP HAND AND CLASSIFICATION BY CODE AT 73.4'F AS RTRP-ilCZ TIGHT, THEN TIGHTEN WITH STRAP WRENCH._O OR RTRP-11AE.FITTINGS SHALL BE COMPRESSION MOLDED NOT OVERTIGHTEN. NORMALLY ONE HALF TO ONE ! OR FILAMENT WOUND USING A MINIMUM OF 60% CHOPPED REVOLUTION IS REQUIRED AFTER HAND TIGHT GLASS FIBER. (PROPER HAND MAKE UP FOR 2' FITTINGS IS APPROXIMATELY 5 THREADS). WHEN USING POWER 2.2 PIPE AND FITTINGS SHALL MEET ALL DIMENSIONAL TONGS, 75 FT. LBS„ IS SUFFICIENT. DO NBT AND PERFORMANCE REQUIREMENTS, MECHANICAL PROPERTIES, FORCE THREADS, IF THREAD DOES NOT MAKE UP AND SHALL BE MARKED WITH A U.L.LABEL FOR NOW CORRECTLY,BACK OUT AND RECLEAN. METALLIC UNDERGROUND PIPING FOR PETROLEUM PRODUCTS. 5.5.2 MAKING THE FIBERGLASS JOINT f 2.3 WORKING LIMITS • BE CERTAIN THAT THERE IS STRAIGHT ALIGNMENT. 2.3.1 PIPE -PRESSURE RATING SHALL BE IN ACCORDANCE WITH ASTM TEST METHOD D-2517, AND ASTM D-2517 • INSERT SPIGOT ALL THE WAY INTO BELL. FOR BURST PRESSURE. VDUALOY 3000/L') 2.3.2 ADHESIVE - ULTIMATE SHEAR STRENGTH OF ADHESIVE • TWIST AND PUSH TO GET FRICTION LOCK. AND CURING AGENTS SHALL BE IN COMPLIANCE WITH ASTM D-2517, AS APPROVED AND SUPPLIED BY *'RED THREAD II' PIPE IS SUPPLIED FROM THE j MANUFACTURER. MANUFACTURER WITH T.A.B. (THREA3ED AND BONDED)SELLS AND SPIGOTS. APPLY ADHESIVE 3.0 CODE RESTRICTIONS AND SCREW TOGETHER AS TIGHTLY AS POSSIBLE ) BY HAND. ALL UNDERGROUND PIPING SHALL BE IN ACCORDANCE WITH THE FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE,NFPA NO. •AVOID COCKING JOINT. 30, AND ALL APPLICABLE STATE AND LOCAL CODES. • OVER INSERTION CAN CRACK SPIGJT END AND 4.0 ACCEPTABLE MANUFACTURERS -FIBERGLASS REINFORCED EPDXY (FRP)PIPE CAUSE A LEAKY CONNECTION. 4.1 AMERON 'DUALOY-3000/L' •UNDER INSERTION CAN CAUSE A LEAKY CONNECTION. # 4.2 SMITH FIBERGLASS 'RED THREAD II' • DO NOT DRIVE THE CONNECTION TOGETHER WITH 5.0 INSTALLATION A HAMMER. 5.0.1 INSTALLATION SHALL BE IN STRICT ACCORD WITH THE • DO NOT DISTURB THE CONNECTION WHILE THE MANUFACTURER'S INSTRUCTIONS AND SUN'S PLANS AND ADHESIVE IS UNCURED. AVOID MOVING PIPE SPECIFICATIONS. AND FITTINGS UNTIL ADHESIVE IS SET. 5.0.2 ALL PIPES AND LINES SHALL BE INSTALLED WITH A 5.5.3 WHEN AMBIENT TEMPERATURES ARE 70-F OR BELOW, UNIFORM CHANE IN GRADE, PITCH OR SLOPE. IN HEAT SHOULD BE APPLIED TO BOND JOINTS FOR INCH PER FOOT NOR GREATER 11 INCH PENERAL, THIS SLOPE WILL NEVER BE LESTHAN PROPER CURING OF THE ADHESIVE. 'FORCED' THAN CURING SHALL BE PER MANUFACTURER'S R FOOT AND WILL SLOPE BACK TO THE TANK WITH INSTRUCTIONS THROUGH THE USE OF A CHEM CURE NO PEAKS OR POCKETS. ALL PIPING AND FITTINGS PAK OR ELECTRIC HEAT BLANKET/COLLAR. 'FORCED' SHALL BE INSTALLED FREE OF SAGS, BENDS, OR CURE TIME IS ONE (1)HOUR AT AMBIENT ANY OTHER CONDITION THAT COULD PROVIDE POCKETS FOR TEMPERATURES DOWN TO O'F.AT LOWER AMBIENT CONDENSED PRODUCT TO COLLECT. IF AN UNUSUAL TEMPERATURES OR WHEN USING EXTRA HEAVY FITTING, GRADE CONDITION EXISTS AND SLOPES ON PIPING REDUCER BUSHING ETC., SPECIFIC RECOMMENDATIONS CANNOT BE MET CONTACT SUN'S FIELD ENGINEER OR SHOULD BE REQUESTED FROM THE MANUFACTURER. AUTHORIZED REPRESENTATIVE. 5.5.4 ALL FIELD CUTS AND TAPERS TO BE MADE WITH THE 5.0.3 PROVIDE A MINIMUM 4 FOOT LENGTH OF FRP PIPE ON PROPER TOOLS AND AS PER MANUFACTURER'S EITHER SIDE OF ANY DIRECTIONAL CHANGE EXCEEDING 30'. INSTRUCTIONS. 5.0.4 AVOID PIPING OVER UNDERGROUND TANKS AND NEVER 5.6 ADHESIVE PIPE BENEATH BUILDINGS. MIX AND APPLY ADHESIVE AS PER MANUFACTURER'S 5.0.5 PROVIDE MINIMUM CLEARANCE OF ONE (1) PIPE INSTRUCTIONS_ DIAMETER BETWEEN PIPES. 4 00 NOT ADD MORE HARDENER THAN SPECIFIED (THE RATIO OF 5.0.6 ALL LINES SHOULD BF LAID STRAIGHT USING A FRP HARDENER AND RESIN IS RI CAL) 'CONTROL JOINT' (FITTINGS, IE.. 45' AND 90' ELBOWS, AND PIPE NIPPLES) TO NEGOTIATE 5.7 PRECAUTIONS DIRECTIONAL OR ELEVATION CHANGES. 1 NOTE:GALV.'SWING JOINTS* TO BE USED ONLY AVOID CONTACT WITH ADHESIVE AND HARDENER ON SKIN, DO WHEFE INDICATED. NOT INHALE FUMES. DURING PRESSURE TESTING SUDDEN OR EXCESSIVE PRESSURE SURGES SHOULD BE AVOIDED. 5.0.7 DO NOT LAY P[PE AGAINST SHARP OR HARD OBJECTS. IF LAID NEAR OR THROUGH SUCH OBJECTS, IE.,CONCRETE, 5.8 TESTING - NOTE: ISOLATE TANKS FROM PRODUCT PIPING WRAP WITH RUBBER OR FOAM PADDING, OR SLEEVE 1 W/ FRP PIPE FOR PROTECTION. 5.8.1 PRODUCT AND VENT PIPING - BEFORE PIPE TRENCHES AREACKFILLED AND WITH LINES ISOLATED FROM 5.0.8 PIPE SUPPORTS USED DURING INSTALLATION ARE TO BE TANK PRODUCT PIPING SHALL Bi� PRESSURE -'TESTED WITH REMOVED PRIOR TO BACKFILL. SUBGRADE TO PROVIDE 50 PSI AIR. TANKS AND VENT PIPING SHALL BE PRESSURE SUPPORT TO PIPE AND COMPACTED TO PREVENT SETTLING. TESTED WITH 5 PSI AIR. NOTE- (1) PRODUCT LINES PIPE SHOULD BE COMPLETELY SUPPORTED UNDERNEATH TO BE TESTED FROM THE SUBMERSIBLE PUMP TO BEFORE OVER BURDEN IS APPLIED. THE SAFETY SHUT-OFF VALVE LOCATED UNDER THE BASE OF THE DISPENSER, (2) PRODUCT LINES TO REMAIN ; 5.0.9 FRP PIPE SHIPPED TO JOB SITE TO BF 20' (DUALOY - 3000L) PRESSURIZED (50 PSI) UNTIL G.C. HAS COMPLETED OR 30' (RED THREAD 11) LENGTHS (MAXIMUM) ALL CONCRETE MAT. ISLAND AND DRIVE WORK(GAUGES TO BE CHECKED PERIODICALLY TO ASSURE SYSTEM TIGHTNESS) 5.0.10 SEE PLOT PLAN FOR TANK LOCATIONS, AND FIELD ENGINEER OR AUTHORIZED REPRESENTATIVE FOR PIPE 5.8.2 ALL PIPING COVERED BY THE CONTRACT SHALL BE RUN DETERMINATION. TESTED IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. ANY DEFECTS 5.1 GALVANIZED STEEL PIPING SHALL BE CORRECTED AND THE PIPING THEN RETESTED UNTIL APPROVED BY THE OWNER'S TO BE USED ONLY WHERE INDICATED ON THE PLANS, SHALL REPRESENTATIVE.NOTE-ALL HEAT PAKS TO BE BE SCHEDULF'40 (ASTM A-120)WITH GALVANIZED MALLEABLE REMOVED FROM JOINTS PRIOR TO TESTING. IRON (150 LB.)FITTINGS_ALL JOINTS TO BE SEALED WITH GASOILA SOFT SET W/TEFLON, JOMAR HEAVY DUTY 5.8.3 NOTIFICAMN -- THE OWNER'S REPRESENTATIVE SHALL W/TEFLON,RECTORSEAL HEAVY DUTY 100 VIRGIN W/TEFLON BE GIVEN ADEQUATE NOTICE (SEE TANK TEST OR LA -CO LOC HIGH PERFORMANCE PIPE SEALANT W/TEFLON NOTIFICATION REOUIREMENTS)BY THE CONTRACTOR APPLIED TO MALE THREADS.ALL GALVANIZED PIPING AND OF THE READINESS TO PERFORM TESTS. RECOMMEND FITTINGS. INCLUDING STEEL RISER PIPES AT TANK, TO BE 48 HOURS NOTICE IN ADVANCE. PROTECTED WITH A COATING OF KOPPERS 300M ( 1-800-547-24613 ). SONNF- THE CONTRACTOR SHALL FURNISH ALL 5.8.4 EERL IM TO BE PRIMED WITH A COATING OF KOPPERS NOTE: PIPE TO BE INSTRUMENTS, TEST EQUIPMENT, AND PERSONNEL b '�40 AT (ORDER SEPARATELY), REQUIRED TO CARRY OUT THE VARIOUS TESTS. 5.2 TRENCH EXCAVATION ----- 5.8.5 CERTIFICATION -THF RESULTS OF THESE TESTS } 5.2.1 THERE SHALL 9E A MINIMUM OF 6' OF SHALL BE TABULATED AND CERTIFIED, AND 1/8' TO 3/4'PEA GRAVEL, OR 1/8' SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR TO 112' WASHED. FREE FLOWING ANGULAR STONE APPROVAL. g CRUSHINGS BEDDING UNDER THE PIPE COMPACTED TO OBTAIN A FIRM UNIFORM SLOPE. AVOID SHARP 5.8.6 50* AIR TEST -ALL PRODUCT PIPING SHALL BE AIR STONES OR ROCKS IN EXCAVATION TRENCH. THIS TESTED TO 50 PSI (POUNDS PER SQUARE INCH) BED MATERIAL TO BE PLACED ON AN EXCAVATION WHICH MUST BE MAINTAINED WITHOUT PRESSURE DROP UNTIL OF CONTINUOUS FIRM BEARING SOIL. BACKFILLING. CONCRETE MAT, ISLAND AND DRIVE WORK ARE COMPLETE. DURING THIS TEST, PRIOR TO 5.2.2 FRP PIPE INSTALLED BENEATH ASPHALT OR BACKFILLING. ALL PIPE •JOINTS, CONNECTIONS AND FITTINGS CONCRETE SURFACES SUBJECT TO TANK TRUCK SHALL BE CHECKED BY COATING THEM WITH A RICH TRAFFIC SHALL HAVE A MINIMUM COVER OF 12' SOLUTION OF SOAP AND WATER FOR PHYSICAL (TOP OF PIPE TO BOTTOM OF DRIVEWAY 'BASE') OBSERVATION OF LEAKS AS EVIDENCED BY SOAP BUBBLES. I CAUTION MUST BE TAKEN THAT ALL TANKS BE COMPLETELY 1 5.3 TRENCH FILL ' ISOLATED FROM THE PIPING DURING THIS TEST AS THE TANKS THEMSELVES ARE NOT CAPABLE OF WITHSTANUING ALL PIPE TRENCHES ARE TO BE BACKFILLED WITH THIS AMOUNT OF PRESSURE. ANY DAMAGE TO TANKS AS A 1/8' TO 3/4' PEA GRAVEL, OR 1/8' TO 1/2' WASHED. FREE. RESULT OF OVER -PRESSURING SHALL BE CORRECTED AT THE � FLOWING ANGULAR STONE CRUSHINGS AND COMPACTED IN EXPENSE OF THE CONTRACTOR. ALL TERMINAL 6' LAYERS TO HAXIMUM DENSITY. POINTS SHALL BE CAPPED AND/OR PLUGGED DURING TEST AND BE AVOIDED WHILE UNDER PRESSURE. 5.4 INSPECTION NO LINES SHOULD BE BACKFILLED UNTIL TESTED AND CERTIFIED TIGHT. 5.4.1 DURING TRANSPORTATION, STORAGE AND HANDLING, PIPE (FRP AND GALVANIZED) CAN RECEIVE ROUGH TREATMENT. 5.8.7 CAUTION - DO NOT OVER PRESSURIZE SYSTEM BEFORE INSTALLATION ALL PIPE AND FITTINGS SHALL MAINTAIN SAFETY PRECAUTIONS AT ALL TIMES. BE CAREFULLY INSPECTED FOR POSSIBLE DAMAGE, APPLY PRESSURE SLOWLY TO ACHIEVE TEST ESPECIALLY TO THE TAPER (SPIGOT)OR THREADED ENDS. PRESSURE AND SLOWLY RELIEVE PRESSURE UPON ¢ PIPE IS NOT TO BE INSTALLED IF THERE IS EVIDENCE COMPLETION OF TEST. OF WEAR OR DAMAGE.FIELD ENGINEER OR AUTHORIZED r" 5.8.8 P T - UPON COMPLETION OF WORK REPRESENTATIVE WILL REQUIRE ALL DAMAGED PIPE TO BE (FINISHED CONCRETE AND ASPHALT IN PLACE)AND REMOVED AND NEW PIPE INSTALLED AT THE EXPENSE OF PRIOR TO DISPENSING ANY PRODUCT, THE CONTRACTOR THE CONTRACTOR. SHALL PROVIDE PRECISION TESTS (PETRO-TITE OR LEAK' LOKATOR)OF ALL UNDERGROUND TANK AND PIPING SYSTEP'19. PIECES OF INSTALLED PIPE ARE TO 5.4.2 ANY DAMAGED PI THESE TESTS SHALL CONSIST OF A FULL SYSTEM TEST BE REPAIRED CUT OUT AND REPLACED PER AS WELL AS INDIVIDUAL (30 - 50 P$D LINE TESTS ON PLL MANUFACTURER'S INSTRUCTIONS. IMPACTED AREAS ARE DISCHARGE PIPING,ALL TESTS SHALL BE IN ACCORDANCE. FOUND BY LOOKING FOR LOCALIZED COLOR DIFFERENCES WITH STANDARD INDUSTRY PRACTICE AND IF APPLICABLE, SHALL (CALLED 'STAR CRAZES'). CONFORM TO ALL REQUIREMENTS OF THOSE REGULATORY ) AGENCIES HAVING JURISDICTION. UPON COMPLETION OF THE 5.5 CONNECTIONS PRECISION TEST, THE CONTRACTOR SHALL SUPPLY TEST RESULTS AS WELL AS WRITTEN CERTIFICATION OF SYSTEM 5.5.1 ALL PIPE MUST BE CLEAN, FREE OF SAND, DIRT, TIGHTNESS TO THE ENGINEER. ) OIL AND GREASE AT CONNECTION ENDS. 9 • JOINT CLEANER SHOULD ALWAYS BE USED SPARINGLY 5.8.9 PRODUCT PRESSURE TEST OF PIPE AND VALVE SYSTEM AND ONLY WHEN GREASE OR OIL CONTAMINATION IS • PRESSURIZE SYSTEM WITH RED JACKET PUMP. IT SUSPECTED. ANYTIME JOINT CLEANER IS USED A WILL TAKE THE PRESCRIBED AMOUNT OF TIME OF LIGHT SANDING AFTER USE IS REQUIRED TO TWO SECONDS FOR THE LEAK DETECTOR TO GUARANTEE A GOOD BOND.UNLESS GREASE OR OIL COMPLETE ITS TEST CYCLE IF THERE ARE NO LEAKS, CONTAMINATION IS SUSPECTED DO NOT USE JOINT FULL LINE PRESSURE APPROX.26 PSI WILL CLEANER BEFORE ADHESIVE APPLICATION.A LIGHT REGISTER ON THE GAUGE. SANDING OF NEW PIPE AND FITTINGS IS NORMALLY SUFFICIENT FOR A GOOD BOND. • SEE MANUFACTURER'S INSTRUCTIONS FOR COMPLETE DESCRIPTION OF TEST PROCEDURES FOR PRODUCT PIPE, LEAK DETECTOR,CHECK VALVE,SEALS AND DISPENSER a COMPONENTS. GENERAL NOTES 5.9 INSPECTION AND GUARANTEE 1. CONTRACTOR SHALL VERIFY THAT VENT AND VAPOR LINES ARE NOT TRAPPED 5.9.1 THE OWNER'S FIELD ENGINEER OR AUTHORIZED s AND HAVE PROPER SLOPE. REPRESENTATIVE MUST VERIFY THAT ALL WORK IS IN ACCORDANCE WITH THE FOREGOING, BEFORE 2. VAPOR RECOVERY MANIFOLD SHALL BE INSTALLED PLUMB AND LEVEL. APPROVING ANY PAYMENT FOR THIS WORK. 1 x 5.9.2 THE CONTRACTOR SHALL GUARANTEE HIS WORK FOR 3. SUPPORT MANIFOLD ON CONCRETE BLOCKS (REMOVE DURING BACKFILLING). ONE YEAR (FROM DATE OF ACCEPTANCE BY OWNER'S ENGINEER) AGAINST FAULTY WORKMANSHIP AND/OR 4. USE THREAD SEALING COMPOUND ON ALL MANIFOLD CONNECTIONS, SEE DEFECTIVE MATERIALS, MAKING AT HIS EXPENSE, PIPE SPEC. ABOVE, SECTION 5.1. ALL NECESSARY REPAIRS DURING THIS ONE YEAR GUARANTEE PERIOD IF DUE TO FAULTY WORKMANSHIP t 5. DO NOT ALLOW THREAD SEALING COMPOUND TO ENTER MANIFOLD. AND/OR DEFECTIVE MATERIALS. 6. VALVES SHALL BE SEATED PROPERLY IN MANIFOLD, MALE THREADS TO BE COATED WITH AN ANTI -SEIZE COMPOUND, IE. 'COP-GRAF' (GRAPHITE/ COPPER BASE) OR 'NEVER-SEZZ' (GRAPHITE BASE). 7. DIESEL AND KEROSENE TANKS REQUIRE SPILL CONTAINMENT MANHOLE AT FILL AND FLOAT VENT VALVE & EXTRACTOR ASSEMBLY W/4" X 2' TEE AT VENT. a MODIFIED PRECISION TEST. ADDED KOPPERS PRIMER CB 4 4/88 ELIMINATE SAND BACKFILL,ADDED FG ISOLATING FITTING L �^� , REFERENCE DRAWINGS BETWEEN FLEX CONNECTOR AND SUB. PUMP (DET. 'H*) CAD GALV. SWING JOINT e VENT CONNECTIONS, 4-501 EXTERIOR CONCRETE DETAILS3 0/86 FLEX CONNECTOR 0 SUB. PUMP, SPILL CONTAINMENT CAD 3-413 FIBERGLASS TANKS AND DETAILS - DOUBLE WALL TANKS MH & FLOAT VENT VALVE 0 KERO & DIESEL TKS.{ 3-415 STD. FIBERGLASS PIPING DETAILS & MATERIAL 2 7/85 APPROVED PRECISION TANK TESTS: ,, CAD SCHEDULE - DOUBLE WALL TANKS 3-419 DOUBLE - WALL PIPING DETAILS LEAK LOKATOR AND PETRO TITE 9f DETAIL 'H'; ADD 'PRECISION' TEST, r,� , 1 4/86 USE KOPPERS 300M BITUVASTIC COATING CAD , LQ/1f ��^�, REV. N0, DATE REVtS!ONS MADE BY CNr D. 6 f kPFV'0. SUN REFINING & MARKETING COMPANY Facilities & Dis(rihution Department Philadelphia, PA [ OF STANDARD FIBERGLASS PIPING DETAILS TERRY� h & SPECIFICATIONS DOUBLE WALL: TANKS O GISTERtiQ _ DRAWN CAD MANAGERS APPROVAL DRAWING NUMBER R -V. NO. �FSSlNNAL E� ctaECKEo LRY r� ) Dt''E j t' (Y1 ,f � , 2-)4-$4 SCALE AS NOTED