HomeMy WebLinkAboutThe Cove - Filter RenovationsINSTALL NEW DRY VOLUMETRIC CHEMICAL FEEDER WELD A 30"xl6"xi/4" STEEL PLATE TO TOP OF EXISTING PLATE. SECURE CHEMICAL FEEDER TO PLATE. CONNECT CHEMICAL FEEDER AND PVC PIPING TO EDUCTOR. FINISHED FLOOR EL E V. 20.00 1 BUIL DING £N TRA NCE 3"0 FORCE_ Af.4/N FROM EO UA L IZA T/ON TA NK r� c=a__._= 3`0 SLUDGE 8 SCUM RETURN 4 "0 PEC YCL E 2'0 SL UDGE RE TURN 2 "0 SUMP BENCH MARK RIM EL E V. 20.0 0 SEWER MANHOLE NO. 8 5EPTIG 6«m TO NO. I TpNK TF �4 22.6 0 22.62 22.26 x. EDGE OF PA VEMEN T GRASSED A RFA --- - EXISTING GAS PIPE , JUST UNDER ROOF OVERHANG REMOVE END CAP INSTALLED BY SITE CONTRACTOR 8 INSTALL BALL VALVE 8 4" PVC _ AS INDICATED L IGH T POL E -- c 6 TO SUBSURFA CE DISPOSAL 41A CLEARWELL. SEE BULKHEADPVC WYE �' \ CONNECTION DETAIL. 12" LONG FILLER PIECE W/ONE 6"0 THREADED END CAP END FOR SOCKET WELD OTHER END MALE THREADED. APPROX. LIMIT OF ROOF O GRA VEL ED A PEA w/SHRUBS NOTES: I. ALL FERROUS METAL FIELD CUTS SHALL BE GROUND SMOOTH AS DIRECTED BY A/E. 2. ALL METAL SURFACES TO BE WELDED SHALL BE CLEANED NEAR WHITE IN ORDER TO BE SUITABLE FOR WELDING. 3. ALL METAL SURFACES DISTURBED SHALL BE PAINTED AS SPECIFIED INCLUDING NEW EXPOSED EDGES DUE TO FIELD CUTTING. 4. ALL WELDING TO BE DONE BY A CERTIFIED WELDER. CONNECT TO EDUCTOR ro PVC 1 TRANSFER PUMP 6' TO SEP TQC TA NK NO. I E.G. / 6 " TO SUBSURFA CE DISPOSAL _THREADED END CAP N / •• PVC Z BIT. CATCH BASIN CONC. C.S. EXISTING GROUND E.G. W F.G. FARCE MAIN F.M. 3/32"0 HOLES DATE INITIAL DESCRIPTION I PVC 11 REMOVE END CAP INSTALLED \ x BY SITE WORK CONTRACTOR 8 19.95 INSTALL BALL VALVE 8 6" PVC AS INDICATED. PLAN SCALE: 3/16"=1'-0" NEW AIR SCOUR BLOWER METHONAL PUMP 3/8"0 POLYETHYLENE TUBING r SECURE TO LOWER HANDRAIL. f NO SAGS PERMITTED. t -,x ROTA TING BIOLOGICAL CON TRA C TORS 6" INLET EXISTING WHITE BIRCH TO BE RELOCATED BY A OTHERS JU TREE 20.66 20.66 x CLEARWELL BY SITE CONTRACTOR GRASSED MUL CH A REA EDGE' OF PA VEMEN T �'-- PA VED PA RKING A PEA ---.`� A PPP OX. EXIS T GRADE GAS CLEARWELL TANK PRECA S T CURB i F.G. 3" BIT P 'T SA ND FIL TER CL A RIFIER _ _ _ V GRA VEL APPUR T. RECYCLE BOX i " FOOT VALVE 16 BALL VALVE 6110 PVC F.F. ELEV. 14.5 I, SUMP " _ ; 4" BALL VALVE `-"--J INSTALLED BY SITE 4"m PVC WORK CONTRACTOR 60 GAL. SOLUTION TANK SECTION 'A -A' s SCALE: 3/16"=I'-0" AND/OR LEGEND / •• PVC ONABBREVIATIONS CCRIEOVS CONCRETE PAVEMENT FT BIT. CATCH BASIN CONC. C.S. EXISTING GROUND E.G. FINISHED GRADE F.G. FARCE MAIN F.M. 3/32"0 HOLES 3 110 S TEEL P/PE SANITARY SAN. WATER W SANITARY MANHOLE ED STORM MANHOLE G t�`9I_Tt�Y �4 sdjONAt 4p`G :�" r MUDWELL RELOCATE EXISTING AIR BLOWERS AS DIRECTED TO CL A RIF/ER 6"0 INLET �r. BACKWASH WEIR RAISED EACH FILTER_ CELL_ _ LEVEL FLOAT AS DIRECTED. 3'-0" GRAVEL 12.0 TO 4.8 MM) MUDWELL 1'-0" GRAVEL' (4.8 TO 9.5 MMI 1'-0" GRAVEL (9.5 TO 16 MM) CUT 8 REMOVE EXISTING STEEL PLATE WITH DIFFUSER NOZZLES EXISTING MUDWELL PUMPS TO REMAIN C EXISTING / •• PVC SV WITH L_ - C BL D WER AREA TO CL A RIFIER 304 All SCREEN CUT 8 PLUG EXISTING 3/32"0 HOLES 3 110 S TEEL P/PE OPEN AREA PIPE AS DIRECTED EXISTING DIFFUSER NOZZLES B STEEL PLATE TO BE REMOVED. 304 S.S. 16 GAUGE SECTION B -B EXISTING /" PVC L/ SV I" P. V. C. SCALE: I I/2"=I'-0" BLOWER so -TO FIL TERS CONNECT NEW BLOW R _E_ PIPING TO EXISTING NEW 2"_ PIPING AS DIRECTED AIR SCOUR � BLOWER Q PRESSURE GAUGE WITH PETCOCK STEEL BULKHEAD — -- C_HE_CK_YA V P_/*'_RESSURE RELIEF VALVE INTERIOR SIDE AIR BLOWERS PIPING SCHEMATIC FOR 4" PVC G EL. 15.50 N.T.S. f FOR 4" PVC Q EL. 15.50\, FILTER CELL FILTER CELL NO. 2 NO. I EACH CELL 5'-10"x2'-3" CONTRACTOR TO VERIFY 1-1/2" FIBERGLASS GRATING 3'-0" GRAVE SCS RE WITH AU6" HOLES 8 MIN. L /25% OPEN AREA .aaaa.. .aaaa.. 3 " BACKWASH PIP/NG / SUPPORT (TYP) MAX. --- SECTION C -C SCALE: 1 I/2"=1'-0" Keyes Associates - Architects Engineers Planners Interior Designers Providence,RI*Waltham,Ma•Wethersfieid,CT•Nashua,NH Is MAX. PVC AIR SCOUR PIPE HIGH WATER L E VEL EL . 2I.0 3 110 S TEEL PIPE 6" OUTLET ;;;;;'Z3" R EXISTING PERF. PVC SCOUR PIPE TO WITHIN OF LOWER SCREEN 1'-6" GRAVEL 116 TO 25 MM) INSTALL NEW BACKWASH PUMPS CUT, THREAD AND CONNECT EXIST. 3"0 .STEEL PIPE TO A NEW 3"0 UNION. EL /4.5 r 3"m NIPPLE 8 UNION 4"x3" REDUCER A11 DISCHARGE ELBOW CUT OPENINGS INTO CLEARWELL e MUDWELL AS INDICATED 8 DIRECTED. GRIND EDGE SMOOTH. I I I 4" PVC—FROM---.C-L EAR_WE_LtL TANK. 4" PVC FROM STANDARD PVC I MUDWELL TANK FLANGES 8 GASKETS FOR 4" PVC SCH. 80 /8" THC LANGE FOR 4" PVC WITH GASKETS (8) 5/8"0 S.S. BOLTS 8 3/4"0 BOLT HOLE DIA. NOTE: � r. A 4" PVC MANUFACTURED BULKHEAD FITTING AS AVAILABLE FROM INTERNATIONAL SUPPLY CORP., CRANSTON, R.I. IS ALSO ACCEPTABLE. BULKHEAD CONNECTION DETAIL S.S. SCREEN NOTE BELOW 2"x2"xl/4" STEEL ANGLE TYP 304 S.S. 16 GAUGE SCREEN TOP OF WITH 1/8"0 HOLES MIN. 41% LAYER OPEN AREA 304 S.S. 16 GAUGE SCREEN WITH 3/32"0 HOLES MIN. 62% OPEN AREA EXISTING DIFFUSER NOZZLES B STEEL PLATE TO BE REMOVED. 304 S.S. 16 GAUGE SCREEN WITH 1/2"0 HOLES MIN. 48% OPEN AREA N.T.S. /4"0 NYLON SS LOCK NUT 1 1/2"0FIBERGLASS RETAINER 2"x2"xl/4" ANGLE E rrfF=C� q r " uvea a R-�a a >y .. a s: .6 FILTER RENOVATIONS SI . ICHECKED BY: JJOB NUMBE RrATE E.J.R. A.J.K.' E.J.R. P9372.03 FEB. 1994 1/4"0 SS HEX BOLT GRATING 1/4"0 SS HEX JAM NUT 1/4"0 SS FLAT WASHER A 2"68"C.C, NOTE: EACH SCREEN SHALL BE 304SS WITH I" SOLID MARGIN AROUND PERIMETER AS MANUFACTURED BY HENDRICK MANUFACTURING CO. OF CARBONDALE, PA. OVERALL SCREEN DIMENSIONS SHALL BE 5'-9-1/2" x 2'-2". PLUMDET.OWG PLOTTED:2/4/94 THE COVE AT YARMOUTH DENITRIFICATION FACILITIES WEST YARMOUTH, MASSACHUSETTS SHEET 2 OF 3