HomeMy WebLinkAboutReview Checklist � .-i , .� � _
. TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
• Location: A.M.� Lot� Zone of Coniribution: In Out �creage ✓
-ry �i, ` Commercial: Residential:
Street: ! !�6
Village: � Floor Plan: #Bedrooms: �
Owner: � Installer: '
Address: � Phone:
Phone: �� �g ��,'��c� ����`�,'L���
� �Builder: Engineer:
Address: Phone: -
Phone: <1,��� , �: :�. G��'�� e�,
• �� '
/A S NO
1.Required#of copies received '�""�
2.Date of soils exam and percolation test not older than 2 ears --"�'
3.4-5 ft of naturall occurrin ervious material, above water table
4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.:
8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ' �,/�
9.Leaching minimum 100 ft from wetlands Var.: " " ;,_,..�--
10.Leaching minimum 150 ft from drinking welU25 ft irrigation well Var.: L...�'
11.Tank/leaching minimum 10 ft from property line Var.: t---�
12. S stem meets all other setback r uirements Var.: ,, � �
13.Uses adjustment for ma�umum hi groundwater Var.: --���"'
14.Leaching set 4-5 ft above adj.water or bot�o��o€�t�ast... e Var.:
15.System not in to or subsoil(A,B horizo or 5'remo
16.Pro osed contours are suitable
17. S stem meets slo e re uirements-min. 1/8", '/<" referred �
18. S stem meets breakout requirements PVC liner:' ;N� all: �
19. S ec�ed tee sizes are proper, gas baffle on outlet tee �
20. Sewa e is under 10,000 d for arcel
21.No arbage dis osal ✓
22. S stem ad uatel sized for its intended use {
23.Minimum 6"stone or com acted below tank and dbox
• 24.Manhole covers within 6"of ade, um chamber cover to grade •�.�'
25.Inspection ort on lastic chambers/leach field
26.Electrical ermit for um chamber/S arate meter for du lexes
27.Pum s stem-2" line,wee hole,check valve,tee in dbox, um size -��
28.Septic tank/ ump chamber to be factory wat roofed ��'
29.Vent rovided if leachin below 3 feet, under driveway/ arkin
30.Buoyancy calculations for tank/pump chamber ��✓'
31.En ' eer to ins ect and cert' soils: wall: commercial: " �
32.En ' eer/Registered Sanitarian and Land Surveyor stam s/si ture /� :�' i
33.H-201oading is subject to vehicular traffic, groundwater
34.Title V A lication and permit fee, installer si ture
35.Foundation footing min. 2 feet above adjusted ound water for new house
36.Deed Restriction r uired max. #bedrooms:� max. flow: d
37.Check area lots for oundwater/Label groundwater in Assessor's Ma 5
Plan reviewed by: ' 1 6/03/03