HomeMy WebLinkAboutCape Cod Hospital - Proposed Parking Lot ExpansionSITE PLAN REVIEW DATA:
EXISTING USE: VACANT LAND ADJACENT TO EXISTING PARKING AREA
PROPOSED USE: 02 ASSESSORY USE - PARKING
ZONING DISTRICT: GENERAL BUSINESS
DIMENSIONAL REQUIREMENTS:
REQUIRED
PROVIDED
FRONT SETBACK
30 FT
NA
SIDE SETBACK:
25 FT
NA
REAR SETBACK:
20 FT
NA
FIRST FLOOR AREA:
259
NA (NO BUILDING PROPOSED)
SECOND FLOOR AREA
'
NA
BASEMENT FLOOR AREA:
NA
BUILDING HEIGHT:
<35 FT
NA (NO BUILDING PROPOSED)
USES OF BUILDING:
NA
PARKING CALCULATION:
PARKING AREA AS DETERMINED FOR CCHOSPITAL
NEEDS
HANDICAPPED CALCULATION:
HANDICAP
SPACES PROVIDED ON -SEPARATE -LOT NEAR ENT.
PERCENT IMPERVIOUS COVER (AREA SF): 176,814 SF = 42.9% (INCLUDES EXISTING PARKING AREA)
JV/Nl+
NARJU
30/N2 XIS G
/ PAR NG
A A G
CC SPIT
EXISTING
PARKING
o AREA
\\ HOSPITAL
23/S1
CAPE COD HOSPITAL
PROPOSE,91PARKING AREA
�Q
U
4�
LOCUS
1" = 200'±
7
n�
hondho% /7 / C
•o s X01 \
hondho% /7
/
PRopzRr)' LllyE
APPROXIMATE LOCATION OF
BURIED FIBER OPTIC CABLE
VERIFY LOCATION PROR TO
CONSTRUCTION
20' WIDE BUFFER - EXG. TREES TO
BE RETAINED AND SUPPLEMENTED W/3"
CALIPER TREES TO BE PLANTED
20' C.C. PER T.O.Y. BY-LAW SEC.
301.4.4
EXISTING STEEL STORAGE RACKS
TO BE REMOVED BY BAXTER WELDING
PROP. CHAIN LINK FENCE
/
PROPERTY LINE
SITE UTILITIES
/ PROJECT BENCHMARK - TOP CONCRETJ -BOUND
THE LOCATIONS OF}�DERGROUND UTILITIES SHOWN ON THIS PLAN ARE APPROXIMATE. AT LEAST 721 ELEVATION = 20.54 /
HOURS PRIOR TO ANY EXCAVATION FOR THIS PROJECT WORK, THE CONTRACTOR SHALL MAKE THE /
REQUIRED NOTIF16ATION TO DIG SAFE (1-888-344-7233) AND THE BARNSTA13LE WATER COMPANY FOR
VERIFICATION OF �OCATIONS.
Ej 33
nil/ PROPERTY LINE
CLEARING LIMIT
{
PROPOSED PARKING AREA EXPANSION
I
PROF. -BRAIN LINK FENCE { { I r I { I
/ AT CLEARING LUT
24
� I
I
/
o
SAW CUT AND REMOVE
//- BI OUS CONCRETE BERM — [23.0]
/ 24� ' // /// /
/ , > EXIST FENCE l?¢J
-TO BE, E OCATED
0 CURB AS REQUIRED
22--
EXISTING,T POLE i
To- OCATED
20
ti
00
/ r / EXISTING PARKIN - AREA -' — / / �`-[2p]
CC -PITAL
TM6 �/ .� � / / { 35' FROM EDGE OF WETLAND
27
50' FROM EDGE OF WETLAND
/' ` ` ` •' i { } h I I 00 /' + // z3 zs 2s PROP. CHAIN LINK FENCE
lb
f'fi'Op 2� �' / / '
s / F /
�
-
N /
w/ v�
NOTE:
TOPOGRAPHY COMPILED FROM 1982 AERIAL
_ PHOTOGRAMMETRY, 1996 FIELD SURVEY BY DOWN CAPE
ENGINEERING, AND 1999 FIELD SURVEY IN THE AREA OF THE
EXISTING _ I G/I A �( / / / / / PARKING LOT EXPANSION BY DOWN CAPE ENGINEERING.
cu �� _ \\ / // / / WETLAND DELINEATION BY DOWN CAPE ENGINEERING 1999
/ c fl
CI)i _ , - N ELECTRICAL ENGINEER:
4b MAGNUSON ENGINEERING
24 WAORTLEBERRY LANE
C-� � 14 OENNISPORT, MA 02639
/6' 0 (508) 394-7451 FAX (508) 760-2805
CIVIL ENGINEER:
DAVID C. THULIN, PE, PLS
\ / 211 MILL ROAD
/ EAST .SANDWCH, MASSACHUSETTS 02537
13 (508) 888-2345 FAX (508) 688-7259
/ 7 I 4� 40 0 20 40 80 160
CRANBERRY
BOG z / ` — % (IN FEET )
Q / ` 1 inch = 40 ft.
II
j
I I
LEGEND
_
50-- EXISTING CONTOUR
PROPOSED CONTOUR
EXG. TREE/SHRUB LINE
CLEARING LIMIT
,`? �.Th� ^S• �Yr• i
.v
M,
�.
q 01LA }
of Q }
U
99=034
SHEET 1 OF 4
DCT JOB NO. 99-031
F -F-
Q
0
W
~O
Z
�
rn
W
w
Q
Of
O
m
nY
m
U
Z
Fn
W
O
U)
Q
Ld
Q
C)
V)
J
W<
�
O
'
of Q }
U
99=034
SHEET 1 OF 4
DCT JOB NO. 99-031
X 16.96
EXISTING SPOT ELEVATION
'
o
[70.2]
PROPOSED SPOT ELEVATION
04
TH1
-..
. I
TEST PIT LOCATION
z
<
O
— W —
WATER SERVICE
E13
RESOURCE AREA
zz
Q
Q
J
z
BOUNDARY FLAG
a-
X
Q
}
PROPOSED SILT FENCE
Ld
EXG. LIGHT POLE
O
�
O
w
J
N
PROP. TREE
}
PROP. CATCH BASIN -
Z
`1
0
w
O
U
Q
o_
Qf
wLj
Q
MONITORING WELL
<
O
cn
N
Q
o
W
�-'
0
PROJ. BENCHMARK
(w
uj
s
�
m
O
O
w
o
m
�
of Q }
U
99=034
SHEET 1 OF 4
DCT JOB NO. 99-031