Loading...
HomeMy WebLinkAboutSprint - PCS Site Plan Review - Electrical PlanL SCALE: I I W:\SPRiNT\7472\CAPECOD\73\RBA663E1.DWG 8/4/99 DR ELECTRICAL SERVICE NOTES: 1. CONTRACTOR SHALL VERIFY THAT EXISTING SERVICE, WITH THE ADDITION OF SPRINTS SERVICE SATISFIES SPARE CAPACITY REQUIREMENTS OF NEC. 2. DRAWING(S) WERE COMPLETED BEFORE THE UTILITY COMPANIES COULD CONFIRM THE SOURCE OF SERVICES. DESIGN IS BASED UPON SITE OBSERVATIONS ONLY. TELEPHONE -SYSTEMNOTES 1. TELCO CONDUIT SHALL BE INSTALLED TO ACCOMMODATE THE FUTURE USE OF FIBER OPTIC CABLE. 2. TELCO CONDUIT RUNS SHALL BE AS SPECIFIED AND HAVE A MINIMUM 12" RADIUS BENDS AND ELBOWS FROM PPC TO ACCA. 3. CONDUIT RUNS SHALL HAVE ONE 18"x18"x8" PULLBOX AFTER 270* OF BEND. 4. STRAIGHT RUNS SHALL HAVE A PULLBOX AFTER EACH 75'-0" OF STRAIGHT RUN. 5. CABLE (2) 6 -PAIR (EACH PAIR INDIVIDUALLY SHIELDTERMINAL D4. #24 BOARD CORE TELEPHONE CABLE. INSTALL CABLE WITHOUT SPLICE (FROM BUILDING TE MINAL BOARD TO PPC). LEAVE 15'-0" OF SLACK CABLE AT EACH END. LABEL AS "T-1" AT EACH END AND AT ALL PULL BOXES. 6. PROVIDE 4" DIAMETER, SCHEDULE -40, PVC CONDUIT WITH MINIMUM 3'-0" RADIUS SWEEPS AND ELBOWS FOR UNDERGROUND TELEPHONE CONDUIT INSTALLATIONS FROM TELEPHONE DEMARCATION TO PPC U.N.O. 7. INSTALL PULL ROPES IN ALL CONDUITS UNLESS NOTED OTHERWISE. GROUNDING SYSTEM NOTES 1. ALL GROUNDING CONNECTIONS, MADE THROUGHOUT THIS DRAWING SHALL BE MADE WITH THOMAS AND BETTS KOPR-SHIELD (TM OF JET LUBE INC.). THERE IS NO EQUIVALENT FOR THIS ANTI -OXIDATION COMPOUND. NO OTHER COMPOUND WILL BE ACCEPTED. COAT ALL WIRES BEFORE LUGGING. COAT ALL SURFACES BEFORE CONNECTING. 2. CONTRACTOR SHALL VERIFY THE ADEQUACY OF THE INSTALLED SYSTEM. CONTRACTOR SHALL CONDUCT "SITE RESISTANCE TO EARTH GROUNDING TESTING" PER SPRINT STANDARD 96104 - RELEASE 5. INSTALLED SYSTEM SHALL ACHIEVE A GROUND RESISTANCE OF LESS THAN 10 OHMS. 3. RECORD GROUND RESISTANCE TEST RESULTS ON SPRINT SPECTRUM "GROUND RESISTANCE TEST" FORM. 4. TEST SHALL BE WITNESSED BY SPRINT REPRESENTATIVE. r --I 2 E SCALE: 1/4" = 1'-0" ...... . ...... T . . . .... ..... . ... . .... ... .... ........ \ ................ x 2 1 16 E4 E2 y ............ 2 a 1 328 E3 IF F _-1 SITE PLAN POWER, TELE I El I SCALE: 1/16" = 1'-0" roft OUCH HARBOUR Lo YARMOUTH, PROSPECT HILL WATER TANK &ASSOCIATES LLP DRAWING COPYRIGHT ENGINEERS, SURVEYORS, PLANNERS YARMOUTH WATER DEPT. Q 1999 & LANDSCAPE ARCHITECTS OLD HYANNIS ROAD/ PROSPECT HILL 171 PARK AVENUE --WEST SPRINGFIELD, MA — 01090 YARMOUTH, MA. 02664 P.O. BOX 626 413-746-0796 CHA Project No. 7472-73 6 5 TO LADDER SEE ALSO _NLARGED EQUIPMENT AREA SCALE: 3/8" = l' -O" TEL. 3 Of EQUIPMENT PLAN — POWE I El I SCALE: 1/8" = 1'-0" -A- X7 Sprint Spectrum, LP CROSSROADS CORPORATE CENTER I. INTERNATIONAL BOULEVARD, SUITE 800 MAHWAH, NEW JERSEY 07495 BOSTON MTA SITE NO.: BS23XC663B2 3 1 814,49 ISSUED FOR CONSTRUCTION MOS cmu MSV ISSUED FOR REVIEW OR CMM SLN NO. DATE REVISIONS eY CHK APP'D SCALE: AS NOTED DESIGNED: DR DRAWN: DR 2 ABBREVIATIONS AWG AMERICAN WIRE GAUGE ACCA ANTENNA CABLE COVER ASSEMBLY BCW BARE COPPER WIRE BTS BASE TRANSMISSION SYSTEM CIGBE COAX ISOLATED GROUND BAR EXTERNAL CU COPPER DWG DRAWING GPS GEOSTATIONARY POSITIONING SYSTEM OR GROWTH MIGB MASTER ISOLATION GROUND BAR MIGBE MASTER ISOLATION GROUND BAR EXTERIOR PCs PERSONAL COMMUNICATION SERVICE PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET RGS RIGID GALVANIZED STEEL RWY RACEWAY SSLP SPRINT SPECTRUM LIMITED PARTNERSHIP TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH CODED DRAWING NOTES: OEXISTING UTILITY POLE WITH ELECTRIC SERVICE FOR 200A, 240/124V, 10 AND TELEPHONE SOURCE. PROVIDE SERVICE LATERALS AS INDICATED. O 2- C. w/(3) #3/0. + #6 G. O 2- RGS W1 (2) 6 -PAIR, #24 AWG SOLID CORE TELEPHONE CABLE. OPPC MINI. FURNISHED BY SSLP. COORDINATE STUB UP LOCATIONS WITH EQUIPMENT LAYOUT. O 11/4" RGS W/(3) #2 +#8G. ACCA FURNISHED BY SSLP. POWER CABINET. FURNISHED BY SSLP. 8O PRIMARY RADIO CABINET. FURNISHED BY SSLP. 9O CIGBE. 10 MIGB 11 FUTURE EQUIPMENT @ CABLE TRAY. BOND EACH SECTION. @ #2 SOLID TINNED BCW BURIED GROUND. RING. G BOND TO WATER TANK USING HIGH CAPACITY DISCHARGE METHOD. 15 4"C WA3) 600KCM. 4'-0" METER BANK W.(l) 200A COMBINATION METER/CB SERVICE ENCLOSURE FOR SPRINT AND (1) 200A COMBINATION METER/CB 16 SERVICE ENCLOSURE FOR FUTURE CARRIER BY THIS CONTRACT. METER PAN BY THIS CONTRACT, METER BY UTILITY. COORDINATE INSTALLATION REQUIREMENTS WITH UTILITY. 17 WELL CASING AS PART OF THIS CONTRACT IS AN ADD/ALTERNATE ITEM TO BE DETERMINED AT TIME OF BUILDING. --i Sprint Spectrum, LP ELECTRICAL PLAN JOB NO. I DRAWING NUMBER REV 17472.04.73 RBA663E1 11 27 x 34 1SIZE GENERAL NOTE 1, ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN. ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE ATTACHED SPECIFICATIONS NO. G-001, "TECHNICAL SPECIFICATION FOR CONSTRUCTION" AND NO. G-002, -TECHNICAL SPECIRCATION FOR CONSTRUCTION OF ELECTRICAL AND GROUNDING SYSTEM". IN CASE OF A CONFLICT BETWEEN THE CONSTRUCTION SPECIFICATIONS AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN. IN CASE OF A CONFLICT BETWEEN SSLP STANDARD PRACTICES AND EITHER THE CONSTRUCTION SPECIFICATIONS ON THE DRAWINGS, THE SSLP STANDARD PRACTICES SHALL GOVERN. rp. LEGEND GROUND ROD WELL CASING ■ CADWELD TYPE CONNECTION • COMPRESSION TYPE CONNECTION ........... M" MIGB MIGB O B METER SOCKET 13YOTHERS METER BY UTILITY COMPANY GROUNDING WIRE, #2 BCW U.N.O. UNDERGROUND ELECTRICAL/TEiLEPHONE BY UTILITY CO. -------------- INDICATES EXISTING EQUIPMENT CODED DRAWING NOTE FDETAIL XX NUMBER DRAWING(S) NUMBER 1 814,49 ISSUED FOR CONSTRUCTION MOS cmu MSV ISSUED FOR REVIEW OR CMM SLN NO. DATE REVISIONS eY CHK APP'D SCALE: AS NOTED DESIGNED: DR DRAWN: DR 2 ABBREVIATIONS AWG AMERICAN WIRE GAUGE ACCA ANTENNA CABLE COVER ASSEMBLY BCW BARE COPPER WIRE BTS BASE TRANSMISSION SYSTEM CIGBE COAX ISOLATED GROUND BAR EXTERNAL CU COPPER DWG DRAWING GPS GEOSTATIONARY POSITIONING SYSTEM OR GROWTH MIGB MASTER ISOLATION GROUND BAR MIGBE MASTER ISOLATION GROUND BAR EXTERIOR PCs PERSONAL COMMUNICATION SERVICE PPC POWER PROTECTION CABINET PRC PRIMARY RADIO CABINET RGS RIGID GALVANIZED STEEL RWY RACEWAY SSLP SPRINT SPECTRUM LIMITED PARTNERSHIP TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH CODED DRAWING NOTES: OEXISTING UTILITY POLE WITH ELECTRIC SERVICE FOR 200A, 240/124V, 10 AND TELEPHONE SOURCE. PROVIDE SERVICE LATERALS AS INDICATED. O 2- C. w/(3) #3/0. + #6 G. O 2- RGS W1 (2) 6 -PAIR, #24 AWG SOLID CORE TELEPHONE CABLE. OPPC MINI. FURNISHED BY SSLP. COORDINATE STUB UP LOCATIONS WITH EQUIPMENT LAYOUT. O 11/4" RGS W/(3) #2 +#8G. ACCA FURNISHED BY SSLP. POWER CABINET. FURNISHED BY SSLP. 8O PRIMARY RADIO CABINET. FURNISHED BY SSLP. 9O CIGBE. 10 MIGB 11 FUTURE EQUIPMENT @ CABLE TRAY. BOND EACH SECTION. @ #2 SOLID TINNED BCW BURIED GROUND. RING. G BOND TO WATER TANK USING HIGH CAPACITY DISCHARGE METHOD. 15 4"C WA3) 600KCM. 4'-0" METER BANK W.(l) 200A COMBINATION METER/CB SERVICE ENCLOSURE FOR SPRINT AND (1) 200A COMBINATION METER/CB 16 SERVICE ENCLOSURE FOR FUTURE CARRIER BY THIS CONTRACT. METER PAN BY THIS CONTRACT, METER BY UTILITY. COORDINATE INSTALLATION REQUIREMENTS WITH UTILITY. 17 WELL CASING AS PART OF THIS CONTRACT IS AN ADD/ALTERNATE ITEM TO BE DETERMINED AT TIME OF BUILDING. --i Sprint Spectrum, LP ELECTRICAL PLAN JOB NO. I DRAWING NUMBER REV 17472.04.73 RBA663E1 11 27 x 34 1SIZE