HomeMy WebLinkAboutReview Checklist / _ ; � . • • TOWN OF YARMOUTH ' � �`p � X79 SEWAGE PLAN REVIEW CHECKLIST ; Location: AM /�� LOT 47 Date of Subdivision Approval � Street �O � �� Zone of Contribution: In Out � Village � Commercial Residential � ,Owner: �OKzP d�,���5 Installer � G�f _ � Builder: Engineer �' �/�/�c7 . � 39�— �39zZ_ T N/A YES NO 1. Required number of co�ies received. � 2. Date of soils exam and percolation test not older than 2 years. � �-- 3. 4 feet of naturallv occumn�oervious material. above water table�new constructionl �-/ 4. Foundation 2 feet above high noint of fronting,road for new construction. � �- 5. �?Vater availabilitv letter from Water Department for new construction. ✓�� ' 6. Benchmark indicated and shown-NGVD if near wetlands. ✓ 7, Buildin� sewer does not.exit center of house. � / ' 8• �ptic tank a minimum of 10 feet from house and deck. ✓ 9. Leachin� a minimum of 20 feet from house and 10 feet from deck. � / �_�eaching a minimum of 100 feet from wetlands. �.i ' 11. Leaching a minimum of 150 feet from drinkin� wells/25 feet from irrieation wells. `� me o r ✓ . 0 m fr ' u ro dwtr ` 14. e h' 4 - eet a v w t f ' mn int or r v . Pr ed nto rs i e m et 1 e / " 1 4" �--�'"' 18. Svstem meets breakout reauirements- �eastone elevation carried out 15 feet minimum. ' � 19. S ecified t s' ar r e outl � w ow 1 c ��" � 1. N � � �2. Svstem a equatelXsized for its intended use: ; / 23. Minimum 6" stone or mechanicallv com�acted below the tank�nd d-box. , 24. Manhole covers within 6" of grade - se�tic tank and g�,p ch�mber. � / 25. Electrical nermit for num�ch�mber. ,/ 26 Pumn svstem- 2" tine weep hole check valve �nitarv in d-box alarm on se��rate circuit ' 7. S —i- a t w ✓ 2 . V t r vi ed i le w 29. En�ineer to inspect and certifv : a, clav removal b. wall construction schedule , c' 30. En�ineer and Land Surveyor stamn and sienature. ' 31. H20 loadin� when svstem subiect to vehicular traf�'ic. ;./� I �2. Title V aonlication and fee si�ned bv a licensed installer. ' 33. Fou dati n f ohn et ve d' e w r 34. ot ubclivide r'or t J 3 19 6 - it �S Subdivided p�ior co A�ri17 19R9 - Phos horus Zone 300' ! Plan reviewed by: �� � ' 07-23-2001 01�22PM FROM SWEETSER ENGINEERING TO 5083982365 P.01 . e� S UiTEETS.ER ENGINE�RINC . P.O.BOX 713—S4UTH DENNIS—MASSACHUSETTS Q266Q TEL(508) 39&3922 FAX(508) 39&3063 LANO SURVEYING—ENGiNEERING—TiTLE 5 SEPTIC SYSTEMS INSPECTION OF SUBSURFACE SEWAGE DISPOSAL Y�TEM � Loc�tion of System: 20 WILD ROSE TERRACE Job# 4889 Client: NICHOLS pate: Qc�pber 26, 2000 - , ,, i, ROBIN W. WILCOX, PRQFESSIONAL LAND SURVEYOR, CERTIFIED SOIL EVALUATOR, DULY LiCENCED AS SUCH IN THE COMM�NWEAL7H OF MASSSACHUSETTS, DO HERE9Y CERTfFY THAT BRUCE MURPHY, YARMDUTH HEAL'TH AGENT AND I HAVE VISUALLY iNSPEC7ED THE OVERDIG OF UNSUITABLE MATERIAL FOR SEWAGE DISPOSAL SYSTEI�AT THE PR�PERTY REFERENGED AB�VE. . ' L% ` . c Robin W.Wi)cooc . .� V G i