Loading...
HomeMy WebLinkAboutEngineered Plans - 2017LEGEND —}—1 PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE SCALE: 1"=20' EXISTING WATER SERVICE TEST PIT O " P ' V " " " " " " 18.0 10 1� 19.0 E1-20.0 Yarmouth 4edtth YJ� l s`4i�1� nt APPROVED Rate 19.3 (craw,) Nom, 51ab @ 6.5 .18.7 v " ) 19.5 0� G 0_ \\� ( 8.0 ,17.9 TBM = EL. 19.4 13ULKHEAD FOUNDATION rJ �V/ N WEST YARMOUTH Buck i 'SCAND P� N-- pG <� tP� � F SWAN 1.PKE SWAN POND LOCUS MAP LOCUS INFORMATION TITLE REF: BK 26586 PG 144 PARCEL ID: MAP 049 PAR. 221 ,0 PROPERTY IS WITHIN A ZONE OF CONTRIBUTION SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 138 SWAN LAKE ROAD I WEST YARMOUTH, MA i PREPARED FOR 17.3 CARROLL/ READY ROOTER EXC JUNE 12, 2017 (-• 1"5.)1 Survey by. Weller & Assoc. OF 14'0 1 "' SNI R P� MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 744 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=20.0t SEPTIC TANK PROPOSED D -BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE F.G. EL.=19.301 F.G. EL.=18.40f � F.G. EL: 18.201 L = 26' 9" MIN COVER/ 36" MAX COVER L = 25' L = 1O'(MAX) ® S=1% (MIN.) 4"SCH40 PVC EL. = 17.50 0 S=1% (MIN.) 0 S=1% (MIN.) " 4"SCH40 PVC 4"SCH40 PVC LOAMY SAND 10" 14 8 i O 10YR 3/2 48' LIQUIDINV.=16.25 LEVEL 18.25 INVERT INV.=15.65 - \INV,=16.50 GAS BAFFLE PROPOSED B D -BOX INV.=15.75 LOAMY SAND INV.=16.0 DH PROPOSED 1.500 GALLON SEPTIC O TANK EXIST. SEWER OUTLET 35" C INV.=17.58 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA BREAKOUT=TOP ELEV.= 16.04 INV. ELEV.= 15.65 BOTTOM ELEV.= 14.71 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 16.04 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. F.G. EL: 18.5 (MAX.) 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (6.46' PROVIDED) BOTTOM OF TESTHOLE: EL:8.25 SEPTIC SYSTEM PROFILE N.T.S. NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS ®. 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 3 ROWS OF 6 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 18 UNITS x 6.25 LF x 4.73 SF/LF = 532.13 SF TOTAL AREA = 532.13 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(532.13SF) = 393 GPD > 330 GPD req'd INSTALL TWO INSPECTION PORTS (MIN.) 3 ROWS OF 6 UNITS AT 6.25'/UNIT = 37.5'/ROW SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER 2.83' PERC SAND EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 3 x 2.83' = 8.49'1 USE 3 ROWS OF 6 -HIGH CAPACITY INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE OF SIP 7DARREN�M.�11'40�� SNI TAR��'� TYPICAL SECTION wT.s. SOIL LOGS DATE: MAY 24, 2017 SOIL EVALUATOR: DARREN M. MEYER, CSE 1614 WITNESS: A. VONHONE, YARMOUTH HEALTH DEPT Elev. T P - 1 Depth 19.0 0" A LOAMY SAND 10YR 3/2 18.25 9" B LOAMY SAND 10YR 5/8 16.08 35" C MEDIUM PERC 0 SAND 14.50 2.5Y 7/4 8.25 129" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I hove passed the Soil Evol. Exam in October, 1999. GENERAL NOTES: 1•*ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS, OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER SUPPLY. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5 REQUIREMENTS. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING SECTION 11' INVERT HVG IT END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER I PROPOSED SEPTIC SYSTEM UPGRADE PLAN I .138 SWAN LAKE ROAD, Prepared for: Carroll System Design and Site Plan by: MEYER & SONS, INC. PO SOX 961 EAST SANDWICH, MA 02537 508382--2922 WEST YARMOUTH, MA Re dy Rooter Exc. SCALE DRAWN DATE N.T.S. DMM 06/12/17 REV DATE CHECKED SHEET NO. DMM 2 of 2