HomeMy WebLinkAboutEngineered Plans - 2017{ Yarmouth Health Department PP VED 264 SE`S_ Name Date �c,c rve e)y 'I �o g► w 1 Z_ i SLNee_-Se,r PROPOSED SEPTIC SYSTEM UPGRADE PLAN 39 PAYSON PATH, WEST YARMOUTH, MA Il'•- for: Karras System Design and Site Plan by: MEYER &SONS, INC. PO BOX 981 EASTSANDIMCH, MA 02537 508-362-2922 SCALE N.T.S. DRAWN DMM DATE 05/11/17 REV DATE CHECKED DMM SHEET N0. I o - '0 i l I :-I- Vf_, \ l u 16% _ � o re - TA { Yarmouth Health Department PP VED 264 SE`S_ Name Date �c,c rve e)y 'I �o g► w 1 Z_ i SLNee_-Se,r PROPOSED SEPTIC SYSTEM UPGRADE PLAN 39 PAYSON PATH, WEST YARMOUTH, MA Prepared for: Karras System Design and Site Plan by: MEYER &SONS, INC. PO BOX 981 EASTSANDIMCH, MA 02537 508-362-2922 SCALE N.T.S. DRAWN DMM DATE 05/11/17 REV DATE CHECKED DMM SHEET N0. I o - '0 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=100.0± SEPTIC TANK PROPOSED D -BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6' OF FINISH GRADE SET TO 6" OF GRADE F.G. EL.=100.3± F.G. EL.=100.0± /- /-' /-F-G. EL: 100.501 9` MIN COVER/ 36" MAX COVER ` L = 50' L = IO'(MAX) ® S=1% (MIN.) EL = 27.0 0 S=1% (MIN.) ®S=1% (MIN.) 4`SCH40 PVC 4`SCH40 PVC Zo 4"SCH40 PVC EXISTING jLilo"I14 6 11.3" TO �" LIQUID EXISTING INVERT LEVEL INV.=97.10 - GAS BAFFLE ) TI EXISTING �� INV.=97.30 EXISTING 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLET SEPTIC SYSTEM PROFILE N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: INCREASE FROM 3 BEDROOM TO 4 BEDROOM DESIGN DESIGN FLOW: EXISTING 351 gpd, ADD 1 BEDROOM FLOW FOR TOTAL OF 440 gpd (min) DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: EXISTING SEPTIC TANK: EXISTING 1,50OG SEPTIC TANK O NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 97.49 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOS S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. `F.G. EL: 100.0 (MAX.) LEACHING AREA REQUIRED: (440)/.74 = 594.59 S.F. o L! Rip m� PRIMARY S.A.S. 1 t� '. 114 USE ONE (1) HICAP INFILTRATOR WITH 4' STONE ON ALL SIDES �sist ° (14.25'L x 10.83'W x 0.92'D)N1TAR��`� BOTTOM AREA: 14.25 x 10.83 = 154.32 SF SIDE AREA: (10.83 x 0.92) + ((14.25 x 0.92) x 2) = 36.18 SF TOTAL SQUARE FEET PROVIDED = 190.5 SF DESIGN FLOW PROPOSED: 0.74(190.5 S.F.) = 140.97 G.P.D. EXISTING DESIGN FLOW: 351.00 G.P.D. TOTAL FLOW: 491.97 G.P.D. INSTALL TWO INSPECTION PORTS (MIN.) TOP OF UNIT = EL. 97.49 ri BOTTOM ELEV.= 96.18 1 HICAP INFILTRATOR W/4' STONE ON ALL SIDES 5' MIN. ABOVE BOTTOM OF (14.24'L x 10.83'w x 0.92'D) T.P. EXCAVATION OR G.W. (6.28' PROVIDED) BOTTOM OF TESTHOLE: EL:89.10 SOIL ABSORPTION SYSTEM (PROFILE) SOIL LOGS DATE: MARCH 25, 1999 SOIL EVALUATOR: ROBIN WILCOX, SWEETSER ENG. WITNESS: A. VONHONE, YARMOUTH HEALTH Elev. TP -1 Depth 100.1 0" A LOAMY SAND 10YR 3/3 98.92 B 14" y LOAMY SAND 10YR 5/4 97.28 34" C l ,I FINE SAND / 10YR 6/3 89.10 1 132" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED • 1, Darren M. Meyer, R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I hove pasted the Soil EvaL Exam in October, 1999. GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY ,THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER SUPPLY. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. SECTION 11` INVERT HEIGHT END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 39 PAYSON PATH, WEST YARMOUTH, MA Prepared for: Karras System Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 05/11/17 PO BOX 981 EASTS NDWICH, MA 02537 REV DATE CHECKED SHEET NO. 506-362-2922 DMM 2 of 2