HomeMy WebLinkAboutEngineered Plan - 20171.7' SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE IIFILTER FABRIC OVER STONE 30.5' MINIMUM .75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE PRECAST H-10 NOTE: 2•• MIN. WALL RISERS (TYP.) THICKNESS REQUIRED BLOCKS OR 2'0 4"�SCH40 PVC MORTAR ALL PRECAST RISERS 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS H-10 12" MIN. INT. DIM. 4' (NP•) 4' ENDS SIDES 28.03' 10" 1500 GAL H-10 14"°_°_ ^e° .. _ .. •i O O O O ,-O;0°00;0 27.82' TEE SEPTIC TANK TEE n --o-? ° ° ° ° �l]�� ���� 0���—O _D��O ;00000000 7.57 0-0 ° ° 0000aoa0000 oaaooE o!] F °0°0°0° ° °ATERTEST D'BOX 0 0 0 0 0 0 0 o 0�������0�� ����00���0� X00000000 GAS BAFFLE.., °OR LEVELNESS N 100000000 00oo�ooaaao oa000000000 :000000004' LIQ. LEVEL (ACME OR EQUAL) 27.47'7.30' >°0°0°0°0 °°°°°°0° 25'2 00000000000000000000a000000000000�0000000000 ',o^o„o_°_°_o_.�_o 0 0 0 0 0 0_°_°_ _o.o.o 0 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) - co (___L% % SLOPE) FOUNDATION 28' SEPTIC TANK MAX. LEGEN D 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2". SLOPE OF GROUND CO- UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ( 1 % SLOPE) 9' — (-1-7. SLOPE) 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO. INSTALLING ANY PORTION OF SEPTIC SYSTEM ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE 6/1/17 PERC. RATE = < 2 MIN/INCH CLASS I SOILS ELEV. 1 0°l 29.8' A LS 1OYR 4/2 5" B LS 10" f0YR 4/6 29.0' C PERC MS 1OYR 6/8 132" I 118.8' NO GROUNDWATER ENCOUNTERED DCE #17=>28 18.8' BOTTOM TH-1 NO GROUNDWATER FOUND LEACHING FACILITY 'j� kq Le A 1. DATUM IS NAVD 88 2. MUNICIPAL .WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD . OF HEALTH. C - s o • 'o -A at n t. L• �� y. o 7co6 '9L `S'c� 9S a 00 ��i a t Bess HoZetry, e9 na/ a a � 7�0 Locus o ' p t. Noyes 0�• P°nd nd �Of, Pine s Ro° n � ° o 0 � lO 2$ o R° to a 3 e�cury `� Otd 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS ^ 'V'A qA p CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF .ALL UNDERGROUND & SCALE 1 "=2000'f OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 69 PARCEL 54 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE SITE IS LOCATED WITHIN A ZONE it PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. SYSTEM DESIGN: DINING BATH BEDROOM KITCHEN Roots GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING LIVING BEDROOM DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD GARAGE ROOM USE A 330 GPD DESIGN FLOW BEDROOM SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK -FLOOR PLAN - LEACHING: SIDES:1 2 (2 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH Yarmouth Health Department /41APPRD V D ,''Name Date H'F� H of Ass DANIDA ELA�cyG� ., /g AIEL CIVIL OJALA N „ No. 40980 Scale: 1= 20 S/ON � E `` s / 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN OF #9 JANICE ROAD SOUTH YARMOUTH, MA PREPARED FOR CAPE COD SEPTIC/ OGDEN DATE: JUNE 9, 2017 off 508-362-4541 fax 508-362-9880 I downcape.com down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 17-128