Loading...
HomeMy WebLinkAboutBlueberry Path - Kingsway - Bldg125 Fire Protection - Ground FloorTEST WrDRANT FIRST FLQ. GRADE i r RiC' R i I ® GROUND =LR L I NODE L WATER MAIN HYDRAUL G NOTE: THIS DETAIL IS INTENDED FOR HYDRAILIC CALCJLATICN RE=ER=NCE ONLY AND IS NOT A CCN5 7 RUCTION DETAIL. UJATER `LRVICE DETAIL FOR I-J"CRGJLIC CALCULATIONS Cti_Y GROUND FLOOR FLAN SCALE: EXTERIOR I TRERICE NO 600C PRESSURE WALL GAUGE (0-160 PSI), INSTALL CENTRAL MODEL LF RESIDENTIAL WITH NO. 865 GAUGE COCK. FIRE DEPT. CONN POTTER MODEL VSR-SF OF A TYPE A SIZE PIPE RISER THROUGH FLOOR C FLOW SWITCH. APPROVED BY FD ..LO CNK VLv LOCAL z FIRST FLOOR SUPERVISED BALL VALVE (TYPICAL) w 2 i���" FILL CUP / I 3E co(0 I/2 " W LI P O x O � REDUCED PR=55uQE BACKFLOW PR=_v. AP'iTROL EXP. 0 � (Y ww TANK MODEL 0 WATTS 02Q CR NO. ST -5 AMES 400C1✓. , � FOUNDATION - D, 0. VLV TO DRAIN �--i Y) 11/2" FIRE SERVICE RISER DET,41L NTS WITH GLYCOL REFER TO RISER DETAIL FIRE WATER SERVICE BY OTHERS GENERAL NOTES 1. All work shall be installed in a First-class manner consistent with the best current practices. Items not shown on the Drawing, but which are necessary to make a complete Fire Protection System, shall be furnished and installed as part of the work under this contract. 2. All work shall be installed in compliance with NFPA 13R and all governing Codes. 3. All materials and workmanship shall carry the standard warrarnty against all defects For a period not less than one (1) year from the date of acceptance of the work. Any fault due to defective materials, equipment, or workmanship which may develop within that period shall be made good, forthwith, by and at the expense of the Mechanical Contractor, including any damage done to areas, materials, and other systems resulting From this failure. 4. All layouts are diagrammatic and final arrangement shall suit field conditions. 5. Cutting and patching of masonry, concrete, wood framing and other parts or the structure shall be performed by the General Contractor. 6. All piping shall be CPVC and/or Schedule 40 steel. 1. A final system test shall be conducted in the presence of the Yarmouth Fire Dept. S. The sprinkler system shat be Filled with a non-toxic antifreeze solution equal to FireFighter freeze protection solution speciricaly listed for use with BaizeMaster CPVC. HYDRANT TEST TEST DATE 10rv98 TES1; HYDRANT - 44 PSI STATIC 1 38 PSI RESIDUAL FLOW HYDRANT - 662 GPM AVAILABLE RESIDUAL PRESSURi= - 43 PSI TEST PERFOR"iiED BY ARH ENGINEERING, INC. SPRINKLER LEGEND HYDRAULICALLY DESIGNED SPRINKLER SYSTEM NFPA 13 R "UJET SYSTEM" DESIGN AREA - DWELLING UNIT NO. OF DESIGN SPRINKLERS - 4 SPRINKLER DEMAND FLOW - 33.18 GPM INSIDE NOSE STREAM - 0 OUTSIDE HOSE STREAM - 100 GPM RESIDUAL PRESSURE AVAILABLE - 43 SS PSI RESIDUAL PRESSURE REQUIRED - 25.53 PSI EXCESS AVAILABLE PRESSURE - 18.45 PSI 14 SPRINKLERS - CENTRAL MODEL LF PENDANT k=3.0, LISTED RESIDENTAL 2 SPRINKLERS - CENTRAL MODEL LF SIDEWALL 115'-346", k=3.5, LISTED RESIDENTAL YAR"'VIOUTH FIRE DEPT, { DEPUTY Ci 17"t CENTRAL MODEL LF RESIDENTAIL SIDE WALL, 3/8" ORIFICE, 3.5 K (115') RECESSED ESCUTCHEON (WHITE) CENTRAL MODEL LF RESIDENTIAL i PENDANT, 3/8" ORIFICE, 3.0 K 055') RECESSED ESCUTCHEON (WHITE) U PIPE RISER THROUGH FLOOR C PIPE DROP HYDRAULICALLY DESIGNED SPRINKLER SYSTEM NFPA 13 R "UJET SYSTEM" DESIGN AREA - DWELLING UNIT NO. OF DESIGN SPRINKLERS - 4 SPRINKLER DEMAND FLOW - 33.18 GPM INSIDE NOSE STREAM - 0 OUTSIDE HOSE STREAM - 100 GPM RESIDUAL PRESSURE AVAILABLE - 43 SS PSI RESIDUAL PRESSURE REQUIRED - 25.53 PSI EXCESS AVAILABLE PRESSURE - 18.45 PSI 14 SPRINKLERS - CENTRAL MODEL LF PENDANT k=3.0, LISTED RESIDENTAL 2 SPRINKLERS - CENTRAL MODEL LF SIDEWALL 115'-346", k=3.5, LISTED RESIDENTAL YAR"'VIOUTH FIRE DEPT, { DEPUTY Ci 17"t ° 04 u7 CL i ca Q U M W � �g w ..LO z a ° u7 I Uj ^o 03 nz o w ..LO z W z � w co(0 W N to CO CQ O x O � Qw ww E ­4o F, �--i Y) DRAWING TITLE: FIRE PROTECTION GROUND FLOOR DRAWN BY: NDG CHECKED BY: DAG DATE: FEB. 21, 2000 REVISED: PROJECT NO. 48331 SHEET