Loading...
HomeMy WebLinkAbout9 Commercial Street - Site Plan1 PROFILE OF PROPOSED SOIL ABSORPTION SYSTEM 0 -OUTLET ZONING BYLAW WAIVERS REQUIRED 40B COMPREHENSIVE PERMIT 1. BUILDING #1- 7' TO 20' PROPERTY LINE SETBACK FOR BULKHEAD, S.203.5A 2. BUILDING #2- 8' TO 30' PROPERTY LINE SETBACK FOR DECK, S.203.5A 3. WAIVER OF 6' FOR 20' BUFFER FOR 8 CAR PARKING AREA TO STREET LINE, S.301.4.4 4. WAIVER OF 21.476 s.f. TO 40,000 s.f. LOT SIZE REQUIREMENT (ACTUAL LOT SIZE- 36,243 S.f. EFFECTIVE AREA FOR RESIDENTIAL USE 18.524 s.f. S.203.5.0 5. WAIVER OF 73' TO 100' SETBACK TO RESIDENTIAL SINGLE FAMILY DWELLING, S.402.6.7 TEST HOLE LOG TEST BY CHRIS WCKSON, S.E. DAVID FLAHERTY, JR. EAST CAPE ENGINEERING, INC. TOWN OF YARMOUTH HEALTH DEPARTMENT TEST DATE 03/03/04 LFI. / 1 (Ell".) T.H. / 2 (ELEV.) 0.00' xx.x 0.00' xx•x \7� 0.83' )OLx LOAMY SAND 1.33' xx X 1.17' )0(.XLOAMY SAND NO WATER ENOOUH7ERED 2.50' EDIUM FINE SAND C, 12.00• I )x.X NO WATER 04COWTUM NDATION - 2 BUILDING UNITS DISTRIBUTION BOX - 500 GALLON LEACHING DRYWELLS - BLDG X11: 24'f INSTALL RISERS do COVERS TO WITHIN 6' OF FINISHED GRADE 37'f BLDG #2: 39'f ABOVE INLET AND OUTLET 35't ACCESS PORTS. 2- OF -1/8- TO 1-1/2- FINISH -1/2"FINISH GRADEPROVIDE RISER do COVER WITH VALVE BOX WASHED STONE (TYP.) ENCLOSURE AT FINISH GRADE TO ' ALLOW SAMPLING OF EFFLUENT FROM 9" MIN. COVER DISTRIBUTION BOX. PROVIDE RISER 8c COVER 3' MAX. COVER FINISH GRADE TO WITHIN 6" OF FINAL GRADE IN 22.25' 3' MAX. COVER BLDG #1 9" MIN. COVER „ ELEV. 21.75' 3" PROPOSED 21.50' ELEV. 2000 GALLON IN-- OUT -- BLDG #2 22'50' (H-20) SEPTIC TANK ELEV. ELEV. ' } 21.00' t 20.83' cm cm cm OUTLET TEE ELEK THE OUTLET TEE IS TO BE INLET TEE (16" MIN., ELEV. FITTED WITH A GAS BAFFLE. (10- MIN.) PROVIDE 6" COMPACTED 57' X 16' X 2' AND EFFLUENT TEE FILTER. GAS BAFFLE CRUSHED STONE BENEATH USE ZABEL MODEL A -100 -8x18 -VC DISTRIBUTION BOX EFFLUENT TEE FILTER OR INVERT INTO CHAMBER BOTTOM OF SYSTEM APPROVED EQUIVALENT. ELEV.-20.00' (TYP.) ELEV.-18.00' u 6" OF CRUSHED STONE DESIGN: 8 BEDROOM DESIGN (4) 2 BEDROOM UNITS SEPTIC TANK VOLUME: 8 BEDROOMS AT 110 GALLONS PER BEDROOM - 880 GALLONS PER DAY 880 GALLONS PER DAY (200%) - 1,760 GALLONS REQUIRED INSTALL- 2,000 GALLON H-10 SEPTIC TANK LEACH FACIU1W. PERC RATEt < 2 MIN/*C FLOW RATE* 8 BEDROOMS AT 110 GALLONS PER BEDROOM - 880 GALLONS PER DAY EIOTTOMt (57ft.)(16ft.)- 912e.f.(0.74)- 674 GALLONS PER DAY SKEWALL• 2(57ft.+16ft.)2- 2929.f.(0.74)- 216 GALLONS PER DAY TOTAL• 1,204e.f. 890 GALLONS PER DAY INSTALL: (1) 57.0' x 16.0' x 2.0' SOIL ABSORPTION SYSTEM USING 500 GALLON LEACHING DRYWELLS WITH 3/4' TO 1-1/2 DOUBLE WASHED STONE. GENERAL NOTES: G 1. DATUM (MS.)t TAKEN FROM DENNIS QUADRANGLE MAP O 2. MUNICIPAL WATER IS AVAILABLE 3. PIPE PITCH: 1/4" PER FOOT MINIMUM 0 4. MINIMUM GROUND COVER OVER ALL SEWAGE LEACHING FACILITIES: (0.75) FT. O C 5. THIS DESIGN DOES NOT PROVIDE FOR THE INSTALLATION OF GARBAGE GRINDERS. 6. CONTRACTOR TO NOTIFY DIG -SAFE PRIOR TO CONSTRUCTION (1 -888 -DIG -SAFE) C 7. ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE LEACHING FACILITY SHALL BE REMOVED & REPLACED O .WITH CLEAN, MEDIUM SAND. C 0 8. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH COMM. OF MASS. STATE ENVIRONMENTAL CODE TITLE 5. 9. NO KNOWN WELLS PROVIDING WATER FOR HUMAN CONSUMPTION ARE KNOWN TO EXIST WITHIN 100' OF PROPOSED SOIL ABSORPTION SYSTEM. 10. THIS SITE PLAN IS INTENDED FOR SEWAGE SYSTEM DESIGN PURPOSES ONLY. UNDER NO CIRCUMSTANCES ARE BEARINGS, DISTANCES, OR FEATURES SHOWN TO BE USED TO ESTABLISH PROPERTY LINES. 11. DESIGN LOADING FOR ALL PRECAST UNITS: AASHTO H-20-44 WHERE VEHICLE LOADS ARE ANTICIPATED OR WHEN SUBJECT TO 4FT. OR MORE OF SOIL COVER. 12. COORDINATE LOCATION OF HYDRANT WITH THE FIRE DEPARTMENT STORMWATER COLLECTION & RECHARGE SYSTEM DETAIL DRIVING & PARKING SURFACE 000oo000„00o00000 1" BITUMINOUS SURFACE COURSE INSTALL CATCH BASIN GRATES 2' BITUMINOUS BINDER COURSE CAST IRON RISERS de COVERS ® ELEVATION - 21.4' TO FINISH GRADE PITCH PAVEMENT SURFACE TO BASIN GRATES FINISH GRADE , 2' PEASTONE (TYP) •' 6" STRUCTURAL FILL4. L d PITCH' 1/4- PER FOOT ' pA x 4'DEEP °• •i 4'DIA x 4'DEEP %. m�'r ;4 SOLID CATCH SOLID CATCH ^ O'•,';: BASIN/SEDIMENT 1�• ;; %' BASIN/SEDIMENT 6FT x OFT. PRECAST CONCRETE LEACHING ^ SAP < TRAP - BASIN (H-20)�, < t. , t.y . f,. t} ": (•• r n 10'-0" (TYP.) 10" H-20 HANCOR HI -0 PIPE OR EQUIVALENT PITCH: MIN. 1/4" PER FOOT •• O G O O p O 0 C O C C] C G O C 0 Or1-11 000oo000„00o00000 EXISTING SEPTIC SYSTEM j (APPROXIMATE LOCATION) SEE SITE AND SEWAGE / PLAN DATED 7-12-017 �ti��� /C �/ PJti/ .01 Q/ D \ t/ / / SIGN \ 7�AREA� a / 36,243 5C6ft.t / 0.53 acres t \0 \ \ \ EXISTING PAVED , / DRIVEWAY AND / \ \ Z \ 2 PARKING/ \2 \12 \ UTILITY \ PROPOSED BITUMINOUS ' �ZC� 1POLE PARKING AREA (A G / \ PROP05FC, PROPOSED 57'xIG'x2' SOIL /�/\�-C�/�\A� IIX TREE ABSORPTION SYSTEM WITH 500 GALLON - LEACH I NG DRYWELLS a Pi f" "' PROPOSED CATCH BASINS TOP OF GRATE OR 21.4' T. F. r a \ PROPOSED 2000 GALLON (H-20) SEPTIC TANK 0 F'ROPO SED ,y "'" ao, /23 �. �'� rrE PROPOSED SUBSURFACE DRAINAGE PT �G \ oV. Q; '' \ (SEE DETAIL) a 'P \h ' A I o \�L PROVIDE CONCRETE Z�' D' ATG \; ; \ o, \(� SCRATCH PAD OVER •�Z� \ Y 30 �2 ��Cn ELECTRIC SERVICE -101 aD \ 23 // 2 \'I% EITHER SIDE OF-` ER '$ �� 2 a' \ SERVICE C SING A 00 Q'V Z f.A a � \ � BENCF- MARK DTMPP, '(0 1 \ TOP OF CONCRETE / BOUND; EL - 21.04' PROPOSED 6 -OUTLET ! < ry \ DISTRIBUTION BOX PROP. BTS HEAD STORMWATER COLLECTION & RECHARGE SYSTEM NOTES DESIGN IS BASED ON A 25 YEAR STORM, 1 HOUR INTENSITY USING THE RATIONAL METHOD. (SEE DESIGN SHEET) 1. ALL SURFACE DRAINAGE IS TO BE OVER THE PAVEMENT SURFACE 8c CONTAINED BY BERMS OR CURBING. 2. ROOF RUNOFF FROM ALL PROPOSED BUILDINGS IS TO BE CONTAINED BY GUTTERS AND DOWNSPOUTS AND DIRECTED TO SEPARATE SUBSURFACE DRYWELLS OR STONE TRENCHES ALONG THE ROOF DRIP LINE. PLAN SCALE: 1 "=30" \ V \ LEGEND -� UNE TYPES STRUCTURES E PROPOSED UNDERGROUND O PROPOSED CLEANOUT TO GRADE ELECTRIC SERVICE C.O. W PROPOSED 2" WATER SERVICE Dpr PROPOSED DRAINAGE LINE Spr PROPOSED 4'. SEWER LINE ----22 -- EXISTING SURFACE CONTOUR ---0-- 22 PROPOSED SURFACE CONTOUR PROPOSED SURFACE WATER DIRECTION OF FLOW 21.6' PROPOSED SPOT ELEVATION X East Cape Engineering, Inc. CIVIL ENGINEERS . LAND SURVEYORS if 44 Route 28, Or!ecns.` Maas. (508) 255-7120 SITE PLAN SANITARY SUBSURFACE SEWAGE DISPOSAL SYSTEM do SITE DRAINAGE LOCATION: 1265 ROUTE 28 So. YARMOUTH, MA PREPARED FOR: RIVER LANDING APARTMENTS 1265 REALTY TRUST 1 2 3 No. Revision/Issue Date (71071t JOB# 01-200 sheet Date 05-18-05 1 OF 1 Scale AS NOTED is