HomeMy WebLinkAboutReview Checklist r..- G��,��' �-
���� � � TOWN OF YARMOUTH '
SEWAGE PLAN REV�W CHECKLIST ,� , � ' � ������
�
Location: A.M. � Lot_�� Zone of Contribution: In '�nt Acreage �Y ��
Commercial: Residential:-�
Street: � f
Village: Floor Plan: �/ #Bedrooms:�
Owner: � Installer: �l ��
Address: Phone: �� '"
Phone: fr'i�-- / �z � �`L?��i���1�
,
�
Builder: Engineer:
Address: Phone: ' -
Phone: � ��,��� _
. � �
N/A YES NO
1.R uired#of copies received
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturall occurrin ervious material,above water ta.ble
4.Foundation 2 ft above hi int of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.: �
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �_.__--
9.Leaching minimum 100 ft from wetlands Var.: �--- f
10.Leaching minimum 150 ft from drinkin welU25 ft irri tion well Var.:
11.Tank/leachin minimum 10 ft from ro erry line Var.:
12.S stem meets all other setback r irements Var.:
13.ITses adjustment for maximum high oundwater Var.:
14.Leachin set 4-5 ft above ad'.water or bottom of t e` Var.:
15. System not in to or subsoil(A.,B horizons)or 5'remov
16.Pro osed contours are suitable �--�' ,
17. S stem meets slo e r irements-min. 1/8", '/a" eferred -, ✓=--''
18. S stem meets breakout re irements PVC liner: ��� all:
19.Specified tee sizes are pro er, as baffle on outlet tee '�
20. Sewa e is under 10,000 for arcel '
21.No garba e disposal C..�-'�f '
22. S stem ad ua.tel sized for its intended use � � �'� ��?'�� �
23.Minimum 6"stone or com acted below tank and dbox �''
24.Manhole covers within 6"of ade, ump chamber cover to grade �...r--'" �
25.Ins ection ort on lastic chambers/leach field �
26.Electrical ermit for um cha.mber/S arate meter for du lexes �- I
27.Pum stem-2" line,wee hole,check valve,tee in dbo� um size
28. S tic tank/ um chamber to be factory wa roofed L.�''" ;
29.Vent provided if leachin below 3 feet,under driveway/ arkin `---�"
30.Buoyanc calculations for tank/ um cha.mber �--' '
31.En ' eer to ins ect and cerf soils: wall: commerciaL•
32.Engineer/Re 'stered Sanitarian and Land Surveyor stam s/signature '-�""� '
33.H-20 loading is subject to vehicular traffic, oundwater �-�''� '
34.Title V A lication and ermit fee, installer si ture
35.Foundation footin min. 2 feet above ad'usted ound water for new house �.,...� �
36.Deed Restriction r uired ma7�. #bedrooms: max.flow: d �
37.Check area lots for oundwater/Label oundwater in Assessor's Ma !
Plan reviewed by: wo3�o3