Loading...
HomeMy WebLinkAboutEngineered Plan - 2017,L - � � PROPOSED VENT WITH CHARCOAL FILTER TO � ' I = + OVER D BOX 28.5 _ � FINISH GRADE S - - ,, E ��: E L NOTES T.O.F. EL.= 28.5'+- FINISH GRADE OVER CHAMBER 28.5 29.0 G $ rj , . o ABOVE GRADE SLOPE 2/o MIN. OVER SYSTEM „ _ PROVIDE EXTENSION RISER WATER -TIGHT : REMOVABLE WATE TIG .COVER OVER 314 TO 1-1/2" DOUBLE WASHED i 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION WITH COVER OVER INLET 8 RISER TO WITHIN 6 OF FINISHED GRADE E 40 VC STONE TO CROWN OF PIPE 4 SCHEDULE P INSPECTION PORT ACCESS BOX TLE 5 OF THE STATE ENVIRONMENTAL o n „ „ METHODS SHALL BE IN ACCORDANCE WITH TI OUTLET TO WITHIN 6' _OF F.G. I FINISH GRADE � „ MIN SLOPE 1 /o TO F.G (SEE GENERAL NOTE #21) 2 OF 1/8 TO 1/2 .DOUBLE WASHED _ CODE AND ANY APPLICABLE LOCAL RULES. 2 + F.G. OVER TANK EL. - + 5 DIA. OUTLET(S) FND. EL. 8 0 - 28.0 - STONE OR GEOTEXTILE FILTER FABRIC @ : - - 2.. MUST BE APPROVED BY THE BOARD OF HEALTH AND THE _ ANY CHANGES TO THIS PLAN PLACE RISERS ON ALL DESIGNENGINEER. TOP OF SAS = „ 25.50.... CHAMBERS WITH 9 MIN. 3.5 MAX. „ �_ _ PROPOSED4" , ;, 3. 4 SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL EXISTING 4 36 MAX. i INLET PIPES TO 6 OF j -, SCH. 40 PVC 24.50 SEE NOTE #23 SYSTEM UNLESS OTHERWISE NOTED. SEWER PIPE BREAKOUT EL = 25.00 FINISHED GRADE h - SEWER PIPE " - GRADE SHALL NOT BE LESS THAN _ � 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE 3 3 DROP MAX n n } " 3 g L-17_ o 2 DROP MIN PROVIDE WATERTIGHT ELEVATION = 25.00' FOR.A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A --__ LI MIN. SLOPE @ 1% cJOINTS P. ��„ VC IN FROM � (TY ) 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 13 p 4" PVC OUT TO o o THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. � ^' r r SEPTIC TANK o 14 � 2�..� �' � ' O O o CONTRACTOR TO PROVIDE I r uQ LEACHING FACILITY o0 00 5. SLOPE ALL SOLID PIPE AT 1.0 /o MINIMUM. 00 'SPECIFIED DROP BETWEEN „ 00- 12@1 o - THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. INLET AND OUTLET vo 6. � CONTRACTOR SHALL � � 2 o 0 CONTRACTOR {o0 0 0 n ! OUTLET TEE' 25.00 MIN. 24.73. � �, 0 � � � 0 VERIFY CONDITION OF o� i Do SHALL VERIFY SIZE 48 0 0 0 0 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK ' ES . AND CONDITION OF EXISTING TE o o ; o GAS BAFFLE 6 CRUSHED STONE o AND REPLACE AS o � �' � � D � D � O o o � DDD � �; o' FILLING WHEN SYSTEM IS NEARLY COMPLETE AND .READY FOR INSPECTION. SYSTEM IS EXISTING SEPTIC OVER MECHANICALLY o NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH - NECESSARY 6 4.0' 4.0' TANK _ COMPACTED BASE AND DESIGN ENGINEER. i r , 8.5 (TYP) 4.0 4.0 5 OUTLET DISTRIBUTION BOX 4'83 8. ELEVATIONS BASED ON APPROXIMATE MEAN SEA LEVEL DATUM. BENCHMARK ELEVATION OF VARIES � •) P - - - TO BE INSTALLED ON A LEVEL STABLE 30.00' ESTABLISHED ON A NAIL SET IN A PINE TREE AS SHOWN ON PLAN. GR 17.50 BASE. FIRST TWO FEET OF OUTLET i GROUND WATER ELEV. PIPES TO BE LAID LEVEL. 22.50 VARIER 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION t � THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT �- CIS =�r,BER ENO VIEW 3 - 5�O GALL01 I`i-�O C6�'3•-�M�r�I�S _ 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES EXISTING :1.000 GALLON CONCRETE SEPTIC TANK _ ,� � . SS SECTION VIEW �� F. E � �m•- � 1 CRO TYPICAL Cr Ii� PROFILE ISE ,- TO THE DESIGN ENGINEER. TANK _ 8 � 8 !t �, f � 6 H O AI R I LS SEPTIC�•N� OCL � DISTRIBUTIONDETAIL � `CONTRACTOR.TOV`RIFYEXISTI!'tGELEVATI7NiRIOR DST�JG G T _ - I. NOT TO SCALE 10• ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. TO ANY WORK & NOTIFY ENGINEER IF DIFFERENT, NOT TO SCALE NOT TO SCALE NOTES. y...._ 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING / .� •+ I* . TEST P � � � , REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM a • ► _ r ._.. APPROPRIATE AUTHORITY. s • c . it • -- i.) OF THE PROPOSED � 1. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION it .1 _ f` - A SE C SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED 1-i._.:. w' li �.. -- INSPECTOR: Phlhp Renaud 12. LL PTI � LEACHING FACILITY TO ENSURE CONSISTENCY VI!!TH TEST. PIT DATA SHOWN ON THIS PLAN. , -.>. 4- , , :''�,,. ,i►`�j _ . .,_., ., t UNDER PAVEMENT DRIVES -0R i, ,, f r UN MORE THAN 3 FEET OF COVER OR LOCATED S NO CONSISTENT WITH �. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOIL ARE T �- :: ! h i ,.�'` t .. t [ L (Z EVALUATOR. Michael Pimentel E.I.T.TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. T PIT DATA. 'TES . .. - M .. Oct. 19 9 ,, U?2 C.S.E. APPROVAL DATE..: � CRUSHED STONE SHALL BE FREE OF ALL DIRT DUST AND FINES. 13. DOUBLE WASHED _ �. I PROPERTY IS LOCATED WITHIN A DEP APPROVED ZONE II. r ,r 2.) ENTIRE„ ,�. . s �� DATE. June 22, 2017 i CONTRACTOR SHALL REMOVE ALL LOAM AND UNSUITABLE MATERIAL G 14. WHERE REQUIRED, RA N \... r �.� R'EA 1' , : I ,,; TEST PIT #. ,- IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL F rf . --- S� +: ,. r ELEV TOP = 28.50 UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER r4o ER Crb a �.� wID N �r . . � • ; . • � _. � ._. .... � . . _.. �� : � ' -�-- � UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). .. . ,, SAY O .. _ . _., • - , Y. BGS OU AD ., `�---_ _. ELEV WATER - < 17.50 - O,. T _ c _. P ) I! � 4 /� .. -� _. � ., r ; \ � 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN : � �r PERC RATE _ 21minfnch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. i 4i ?S • = 12 - 30 16.` ' _ __ , • � Y w 4-,, LOCUS • DEPTH OF PERC PROPOSED PROJECT IS LOCATED WITHIN... i ASSESSOR S MAP 100 LOT 135 q w t - 67 TEXTURAL CLASS. 1 26 --, 2 �• OWNER OF RECORD. WINTERGATE CAPITAL LAND TRUST LLC TR 10O F TRUST ¢� ONE GREAT WESTERN ROAD REALTY (p G, • rr W -• , , ESS. 29 INDIANA AVENUE Q Tlr � � ADDR r u H� � - �,�, ^•, . ; � ' Fill I - - �y tJ r 11 rtl p,r> �! r n SOMERVI LLE, MA MAP 100 u.h., w x/31 a �, x � \ :v�, `< ...--•�f-.0 4 28.17 1 Sta l OT 135 . , _ ,►... o L Loam Sand + \ C? �, ____ -" X,✓ ZOI`iE 2 �..... q FEMA FLOOD ZONE ,z: ,, 10,089 _ S.F. �, 10Yr 3i2 ,: !, Z � / �:� �. . :, � 5 01 C0583J r- ,I { _ .. --`. COMMUNITY PANEL # 2 0 � 12 27.50 1. I \ ,-;. =:,•, .: , 17. .DEED REFERENCE. L.C.C. #174447 :_ Per ..< 27 I _ n -.. .. � . ... Loamy Sand _ err , .. 30 28.00 18. P #130101 A x ��. .'� _ � .�-�- _ , PLAN REFERENCE. L C. LAN O DRIVEWAY . i . !: t _- ,.,.. ,;;. 10Yr 5/8 -. ..� T TO ORIGINAL CONDITION. •/ , � / � , I... , . : � 19. ALL DISTURBED AREAS SHALL BE RESTORED -- r 25.00 : r IS PLAN IS TO BE USED ONLY 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE THIS r � GRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR SEPTIC SYSTEM UP I 4 I �9 USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. } ...... a_ - 7 FOR t2 r 1 F I _ f � ,� ,•M; ,a; +r�' --� - 21: A 4 PERFORATED SCH. 40 PVC PIPE SHALL BE PLACED IN A VERTICAL POSITION TO A � .ri ;r•11 T &,C YP � i�I`' /, >,.� . Med Sa „ FENCE \ I �� \ X �.. . - w._d r_( t �- �,:_ ,,_.- , .- DEPTH OF THE BOTTOM OF THE SAS AND EXTEND WITHIN 3 OF FINISH GRADE. A _ -� BUST I (TYP) C 2.5Y 6/ V_X_X_ - ,t r. .. r� REMOVABLE THREADED CAP SHALL BE PLACED ON THE TOP TO ALLOW FOR INSPECTIONS. x - 22. OWNER /APPLICANT /CONTRACTOR -SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL f REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. I LOCUS PLAN Q /23.IN ACCORDANCE WITH 310 CMR 15.401 15.405 THE FOLLOWING LOCAL UPGRADE \ MAP 100 _ j SCALE. 1 - 1000',, , -17.50'APPROVALS ARE REQUESTED FROM 310 CMR 15.211 8 310 CMR 15.221 7 . .132 ( ) 15 � cn =� LOT 134 ,,, ~ l - F M SAS TO THE EXISTING DWELLING. / o j 1.) A 4.9 WAIVER (20.0 15.1) FOR THE SETBACK RO THE W ;< o No Standing, Weeping or Mottling Observed #1 co '� 2. A 0,5' WAIVER 3.00' - 3.50 FOR THE MAXIMUM COVER OVER THE LEACHING SYSTEM. W ! /) N EXISTING F- I �yf� .4 -BEDROOM p K1. �v`��'f� 7C O E S G DATA O 6 WELLING h - LEGEND. cn I / D � \ - �•- ._ TOF - 28.5'± -a Z -> !, w , . - , 50x0 EXISTING. SPOT GRADE Q w - -� NUMBER OF BEDROOMS (DESIGN) 4 o � i I i C-1 - DESIGN FLOW 110 GAUDAY/BEDROOM ►n aS' ''` '� -. - 50 - - _ EXISTING CONTOUR = o co �` ti 6 C-2 F- / / / TOTAL DESIGN FLOW 440 GAL/DAY CO - - X 1 r• x o 50 PROPOSED CONTOUR o_�•-- c/O - I :� I �\ o � z DESIGN FLOW X '.200 /o - 880 GAL/DAY : x --_ � EiH' � �. , 28 ,� w I � �n _ � X k-- - . 50 PROPOSED SPOT GRADE ti x n DECK X USE EXISTING 1,000 GALLON SEPTIC TANK - r 15 t �< ! c ❑/tel bJ EXISTING OVERHEAD UTILITIES x 1 _ I INSTALL 3 500 H 20 GAL. CHAMBERS w/ AGGREGATE PROP. D BOX W EXISTING WATER LINE X, _ _ I I DEWALL CAPACITY .. ... _• GAS EXISTING GAS LINE . I, - I .• . , . _ _ EX. 1Iv J. 25.3 _ . ,. _ -•- :..• : - / PERIMETER 2 HIGH 0.74 GPD/S.F. - GAL/DAY PROP:INSPECTlON POT „ .. -: •- - •• -:••.: ,- - - ., •• . _ •- :•• .•. , 33. r (PERIMETER) ( ) ( ) '� _ 5 �._...;•.:..,.. { ' + ' + ' + + _ TEST PIT LOCATION -- .. , ..t : - , ::• ,. _ . r (33.,5 .11.6 5.5 28.2 12.8 (2) (0.74 GPD/ S.F.) 135.6 GAUDAY 2 , �. ... , . ... �, .. •.. •, : , ., ;, •,......CID EXISTING 1,000 GALLON SEPTIC TANK - .-; ::_ i... 5 .. ,: , . •..-.•..... :. •• � .. , . .. -... .. ,BOTTOM. CAPACITY ,... t L , . OTAL REA 0.74 GPD/S.F. - GAUDAY „ ,,..,. (T A ) ( ) j .. .. •• .:TA,1-.. a.... _ t ... ..- Q ' a D 4 SOLID SCHEDULE 40 PVC PIPE sl f :. I _...: ._ • . - PROPOSE x .. 10.0 ---•I .: •-- � -. • . •• :... - : • .. •.:. - -- • : 6 .F. 0.74 G /S.F. - 315.3 GAL/DAY 8x5.... _ .. .... . (42 S ) ( PD ) ,... . .< _ - - .. ., _ ,. .�........:. , . •._ ® PROPOSED DISTRIBUTION BOX I ( t > 18 3 ,< ,. 2 2 8 9 j(: 2 •. .. �• :.: s � .�,-- • ::-• . • TOTALS. X., •• :,-- ,>: , O PROPOSED 500 GALLON H 20 LEACHING CHAMBER � � 3 : 12 _ I .5'--1 - TOTAL NUMBER OF CHAMBERS 7 0 4 - I n � TOTAL LEACHING AREA 609.3 SQ.FT. x 2 8 `� ,' t i 1 450.9 REV. DATE BY APP D. DESCRIPTION , 1 TREELt I t TOTAL LEACHING CAPACITY GAL./DAY �; �, I NE YP „ 24 ) ..� .� � ss.,s _ PROPOSED SEPTIC SYSTEM UPGRADE h .� r t n SYSTEM DIMENSIONS �; h ,C X h ) N89 ,6 50'W ., ., r, .� r SCALE: I"= 10 :; pp PREPARED FOR: �.-`Zg C Perr,rt valid for REPAIR 'O SEPI IC. SYS i H.M: �,�H -PROP. 4 PVC VENT PIPE �- � r 8 : 2 ONLY, .doe to. Stoic end I.u�et septic v,.irrenccs. , . i � a EXACT LOCATION PER OWNER , s CAPEWIDE ENTERPRISES EkIST11V� 1 000 GALLON SEPTIC TAl�sr� � Ileal h review and ;r r rroval rs re urrcd tui o J G 8oacd. ul t approval y _ � l , , v t a �'iKG I Benchmark 1'0 BE UTILIZED IN THIS DESIGN an future additions/ri.uur.rtrgna/erttratigny tq LL.pt. ts+ I y o /or atruciur't�/d�+tllru V , r sewa :r lecrhlres rnr, t; i ! K Nail Set in Pine Tree MAP 100 A - I % 'PF a�1 7O LOCATED ATElevation = 30.00 LOT 136 Yarmouth 91tatfDepat Approx. M.S.L. SWING -TIES r,�e 1 GREAT WESTERN ROAD DESCRIPTION HCA HC -2 CORNER OF STONE (1) 19.1' 61.6' CORNER OF STONE (2) 26.6' 32.9' CORNER OF STONE (3) 34.5' 41.7' CORNER OF STONE (4) 32.5' 46.0' CORNER OF STONE (5) 30.3' - 67.4'