Loading...
HomeMy WebLinkAboutEngineered Plan - 2015ACCESS COVERS MUST BE WI THIN 9" MINIMUM. r / N VERT EL E VA T I DNS : 6' OF FINISH GRADE 98.39 FIRST 2' TO 3' MAXIMUM COVER INVERT AT BUILDING: 96.0 BE LEVEL MIN 2" OF PEASTONE INVERT 1N SEPTIC TANK: 95.5 OR FILTER FABRIC INVERT OUT SEPTIC TANK: 95.25 V DIAM PIPE 3/4- - 1 1/2" DIA. INVERT IN DIST. BOX: 95.02 96.0 & 95.25 94.85 2 ' $o DOUBLE WASHED STONE INVERT OUT DIST. BOX: 94.85 95.5 GAS j� 95.02 94. 8 a, 92.8 INVERT IN LEACH CHAMBER: 94.8 BAFFLE BOTTOM OF LEACH CHAMBER: 92.8 3 OUTLET 2-500 GAL LEACHING CHAMBERS D -BOX W14' STONE AROUND. 12.8'w x 33'l x �'d ADJUSTED GROUND WATER: N/A 1500 GAL H-20 l OBSERVED GROUND WATER: N/A SEPTIC TANK 6" CRUSHED STONE OR BOTTOM OF TEST HOLE l: 86.8 N COMPACTED BASE . � j PROFILE: NOT TO SCALE' ✓�NEc� i. BE�R000 I' SECOND FLOOR PLAN \ LE 0 c8 -w O -G OHW- -T- - CTV- + 40.4 _• .40-••---- F470 I- #era S U,/ki 'i l'ol kms`` . LOCUS MAP D lQ 20 40 CONCRETE BOUND 'WATER L I NE �YDRANT GAS LINE D VER HEAD WIRES LIGHT POST UNDERGROUND ELECTRIC LINE UNDERGROUND TELEPHONE LINE UNDERGROUND CABLEV I S ION LINE SPOT ELEVATION XISTING CONTOUR PROPOSED CONTOUR DESIGN CRI TERIA DESIGN FLOW: 4 BEDROOMS AT //0 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED. 440 G.P.D. X 200% - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE < 5 MIN/INCH SOIL TEXTURAL CLASS - 1 EFFL UENT L OAD I NG RA TE - 0. 74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W14' STONE AROUND. A-606 S.F. 606 S.F. x 0.74 - 448 G.P.D. SOIL TEST PIT DA TA INDICATES INDICA TES PERCOLATION = OBSERVED TEST GROUNDWATER TP #/ 0. HORIZON TEXTURE COLOR 96.8 A LOAMY IOYR SAND 3/3 /2" -------------------- 95.8 B LOAMY IOYR SAND 4/6 24' -------------------- 94.8 C / MEDIUM IOYR SAND 7/4 42 " 120" NO WATER . DATE: NOVEMBER 19. 20/5 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: C 2 MIN/INCH Yarmouth Health Department D ame Date a 86.8 GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE Sl TE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULA T10NS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN J' IN DEPTH SHALL BE CAPABLE OF W I TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG- SAFE " . 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOL TO BE PUMPED DRY AND BACKF 1 L LED . a�P�ZN OF "dAgs9C�� �TERRY o ANN WARNER No. 38721 > , 7 SEP T l C S YS TEM LEES l ON 72 POND STREET. MAP 60 PARCEL l 18 SOUTH YARMOUTH . M ��aVE FEPTTD 4U' U - 2097 PREPARED FOR: HAL1 H p---_ ROBERT E . BARREL 1 8 LANE ROAD. DENNISPORT. MA 02609 S CA L E: l 20 DECEMBER l 20/_5 STEPHEN A HAAS _ ENGINEERING, INC \ P.O. Box 16 Sou t h Denn i s , MA 02660 ( 508) 362-B132 U JOB NO: 15-056