Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 20175 d. e}Wd4eC'• v!-. T e _Tank .SA ♦� moi' <; T �4 - � t •< e Pits _l O • S s t R '%• :roti 7� _...r'f f SM �• Y�nn6uth tj Viaatarc t (.� y � f St t� .t ? t ry .g >< 7 �'- l.t C23?CiY Fez"... • µ'k / LOINS fi Jf�2 i .0 77, LOCATION MAP 1 " = 2000't II ADS ARC 36 (3613BD) /- BIODIFFUSER CHAMBER 'CHAMBERS) 9.625 3 ROWS OF ADS ARC 36(36136D) BIODIFFUSER CHAMBER BED X -SECTION NOT TO SCALE 7724 MANHOLE COVERS FLUSH W\ FINISH GRADE EXISTING TDP OF FOUNDATION EL. 31.39 20" ACCESS WN 6D� I' Ix300 SFlNISH GRADE1 x30.8 4"PVC EXISTING OUTLET PIPE EL. 29.59 SCH 40 S=.02 EL 28.22 , EL. 24.64 EXIST/NG BASEMENT SLAB 10' MIN TO BLDG *CONTRACTOR SHALL RECONFIGURE INTERIOR PLUMBING AND CONNECT LAUNDRY SYSTEM TO MAIN OUTLET PRIOR TO SETTING SYSTEM COMPONENTS INSTALL ACCESS COVER WN12" OF FINISH GRADE PROP r -OUTLET DISTRIBUTION LINES INSPECTION VENT SHALL BE LEVEL. FOR THE 3' MAX(+30.6) PORT x30.2 FIRST TWO FEET x30.4 12"MIN(+28.6) +30.6 L_t r J 41SCH 40 I BREAKOUT EL=27.5 EL 27.59 I Ls" uNE 14" S _ 4 PVC a '6 o SCH 40 -: �_ I , , TM , R a DEP APPROVED: - . x = ,1-F w� ,�.t EL. 27.37_ _� .� . EFFLUENT � EE _� , EL 27.20 FILTER REQU{RED 97 " �_ - � .: 1= aR? E � �; `` � �I c :_ �� `- � �� �s �� �� ��; s •G �� � �•3�, � _ �l�a��� �� EL. 26.51 6 • CRUSHED EL 27.10 �`� ��' �- <<.. -77, STONE «_ .� .,� .. �• STONE 6" CRUSHED STONE, PROPOSED PROPOSED 35' 7 -CHAMBERS ROW PRECAST CONCRETE REIN. CONC. DIST. BOX 1500 GALLON SEPTIC TANK W/6 OUTLETS .MIN. USE: 1-35' LONG x 9.625' WIDE x 13" DEEP 10' .MIN. AGGREGATE FREE LEACHING CHAMBER SYSTEM IN o 20' MIN. TO BLDG 10' MIN. TO SLAB; un BED CONFIGURATION WITH 3 ROWS OF 7 -ADS 13" ARC 36 BIODIFFUSERS(3613BD) SUBSURFACE SEWAGE DISPOSAL SYSTEM GROUNDWATER EL. 21.51 (NOT TO SCALE) (USE ELEVATION 21.51 PER BOH) Q 0 5 OUTLET DISTRIBUTION BOX SEPTIC DESIGN (NOT DESIGNED FOR GARBAGE GRINDER) 1. DESIGN DAILY FLOW: 3 BR. x 110 GPD = 330 GPD W4� 5" COVER 2. SEPTIC TANK: 330 GPD x 2 = 660 GAL. USE: 1500 GAL (MIN) 2� Z3. LEACHING CHAMBERS: P.R. <2 MIN IN CLASS I I m 15.5" j USE: 1-35' LONG x 9.625' WIDE x 13" DEEP LEACHING CHAMBER SYSTEM IN LQ_ 6.5 [--1 � 12"--•I BED CONFIGURATION WITH 21 - 5' LONG ADS 13" ARC 36 BIODIFFUSER o i ii i i I LEACHING CHAMBERS IN 3 ROWS OF 7. W �t I = � 1 1 " , J i 0 O i 11 "18 i' 14.5 TITLE V n fL_____� (PER MODIFIED CERTIFICATION FOR GENERAL USE DESIGN STANDARD ITEM 9.) ---- PROPOSED VENT EFFECTIVE LEACHING AREA 4.80 SF/LF 1- 20"---f PROPOSED AREA: 105 LF x 4.80 SF\LF = 504 S.F. DESIGN NOTES CAPACITY: 504 S.F. x 0.74 GPD/S.F. = 372 > 330 GPD(D.D.F.) 4,000 P.S.I. CONCRETE @ 28 DAYS I FUEL SIZE CONVENTIONAL SEPTIC DESIGN -PER STANDARD - EXISTING STOCKADE FENCE CONDITIONS FOR ALTERNATIVE SOIL ABSORPTION SYSTEMS w2. PROPOSED 1-35' LONG x 9.625' WIDE x D BOX D ETA I L 13" DEEP LEACHING CHAMBER SYSTEM IN (NOT TO SCALE) - 3 ROWS OF 7 ADS ARC36 BIODIFFUSERS PROPOSED INSPECTION PORT SEPTIC NOTES FULL SIZE CONVENTIONAL SYSTEM TOP VIEW PER STANDARD CONDITIONS 0If �- `mo i I (MODEL NO. 361313D) CHAMBER ZPRI , L ILI X �uaz 1. PROPERTY LINE DATA FROM PLAN ENTITLED OCEAN HARBOR ESTATES IN WEST DETAIL YARMOUTH, MASSACHUSETTS, FOR TRUSTEES OF OCEAN HARBOR TRUST", DATED - �� ° D0 C JANUARY 1956, BY GERALD A. MERCER AND COMPANY. RECORDED WITH EFFECTIVE LEACHING AREA BARNSTABLE COUNTY REGISTRY OF DEEDS PLAN BOOK 126, PAGE 89. 4.80 (SF/LF) ° 2. TOPOGRAPHIC SURVEY BY GRADY CONSULTING, LLC DATED JANUARY 25, 2017. C� (BED CONFIGURATION) ° 0 0 0 3. SOILS TESTING BY ROBERT CARLEZON, GRADY CONSULTING, LLC WITNESSED BY AMY VON HONE JANUARY 25, 2017. 4. CALL DIG SAFE 1-888-344-7233 AT LEAST 4 DAYS PRIOR TO COMMENCEMENT I OF CONSTRUCTION. � 5. NOTIFY TOWN AND GRADY CONSULTING PRIOR TO BACKFILLING OF SYSTEM. INSPECTION PORT 6. NO KNOWN WELLS EXIST WITHIN 200' OF THE PROPOSED SYSTEM a 63» 7. THE SITE IS NOT LOCATED IN AN AQUIFER, PROTECTION ZONE IL. W o 60 -{ 8. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A Q - COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE310 URIED B ( CMR 13"�� �- I�3z� a� L 7.13" (TO INVERT) Ems.. 9, 15.221 12)) ( NO STREAMS, SURFACE & SUBSURFACE DRAINS AND WETLANDS EXIST WITHIN 100 �W 34.5 " 10. FT OF THE PROPOSED SYSTEM, EXCEPT AS SHOWN. THE SITE IS LOCATED IN A FLOOD PLAIN DISTRICT. NOT SECTION vlEw SIDE VIEW 11. NO KNOWN EASEMENTS ARE IN THE AREA OF THE PROPOSED SYSTEM. co_ 12. EXCAVATION AND SAND REPLACEMENT IN ACCORDANCE WITH 310 CMR 15.255 (3) 71 _-� ADS BIODIFFUSER ARC 36 j .NOT REQUIRED AS THE SYSTEM IS LOCATED ENTIRELY WITHIN THE 4 FT NATURALLY OCCURRING PERVIOUS STRATA. 0If �- `mo i I (MODEL NO. 361313D) CHAMBER ZPRI , L ILI X �uaz DETAIL - �� i .._l_. 1zo Z�� -1 ! I 00 Z NOT TO SCALE z z C� w z I W 1 I SEPTIC TANK - 1,500 GALLON O5ti In U - 1 � I � z pi o U U CLEANOUT & INSPECTION oZ t i 68" i i OUTLET(iYP) H S - I a EXISTING WATER ,SERVICE APPROX. LOCATION T �� `� 0 F- Z I ( - V) z z Li o I I I CONTRACTOR TO VERIFY LOCATION INLET(typ) ii COVERS S W oz° �aiTW I �I I125 CBDH I I =o l XoK (fnd)4I I o - W ~ � - `,� i _ - - � 4 TOP H-1,0 z ` - --c� - 150.01 SO 40 0"W i > Z. � Tf,_ � d $' TOP H.D. � 68 � H-10 `5Z� -�.,- I \��---- N. 56" 56", INLET OUTLET n 72 H.D. zW / \-`3�-------�---'� � _ ii 3" MALL �' _i oNULp w (---------- EXISTING EDGE OF PAVEMENT ------ tnH ZWL,� O i EXIST/NG EDGE OF PAVEMENT �� ,i � Kl DESIGN -NOTES i�;i oa& 0 4 Z 1. TOP & BOTTOM MATCHING KEY JOINT SEALED V) zo Z O - BUTYL RESIN AS SPECIFIED BY THE MANUFACTURER. m Z � 0 2. TANK COMPLETELY REINFORCED. 4��� G�' 10 0 = 10 20" 30 o Q w _ �` y� - 3. CONCRETE IS 4,000 P.S.I. @ 28 DAYS. t 0 (� ,� WAY 4. AVAILABLE. IN STANDARD, H-10, AND HEAVY DUTY TORo� G s� W NDWARD = 7 y ��� \G. �oo>_� ����,� ScaleI"=10' SEPTIC TANK DETAIL @_ = o o , (NOT TO SCALE) o W 4 EXISTING EDGE OF PAVEMENT _ / EXISTING EDGE OF PAVCUfNT arSo _ __---_--- _- -- dais - 0 o W� z 10- z< EXISTINGOVERHEAD ELECTRIC U UP UP i SOIL LOG T.H.#1 EL. 30.70 0"-1 o" A I SANDY LOAM 29.87 10"-36" B SANDY LOAM 27.70 36"-138" PERC C � 4 MED SAND 38"-56" P.R.<2 MIN/IN 19.20 D= 11'-6" (SEE FRIMPTER ADJUSTMENT) *(USE G.W. EL.=21.51 N.AN.D. 88 PER BOARD OF HEALTH) (SOIL EVALUATION AND PERC TESTING PERFORMED BY ROBERT CARLEZON ON JANUARY 25, 2017, WITNESSED BY AMY VON HONE) REVISION 3/20/17 1 REVIEW COMMENTS SEPTIC R ElPAIR PLAN #79 WENDWARD WAY WEST YARMOUTH, MASSACHUSETTS APPLICANT KATHLEEN LYNN CLASBY & KATHLEEN CHISHOLM FEBRUARY 7, 2017 c/o WIND RIVER ENVIRONMENTAL (PAULA SMITH) SCALE: 1" = 10' 70 BARTZAK DRIVE JOB NO. 17-011 HOWSTON, MA 01746 GRADY CONSULTING, L.L.C. REGISTERED PR9FESS-TONAL CIVIL ENGINEERS & LAND SURVEYORS 71 Evergreen Street, Suite 1, K/ngston, MA 02364 Phone (781) 585-2300 Fox (781) 585-2378 SHEET 1 OF 1