Loading...
HomeMy WebLinkAboutEngineered Plans - 2017N C) U 00 UP .34 ......................... ................ Zoning Compliance V11C7. /\-ru Zoning Existing Proposed Front Setback J0, 64.7' unchanged -Min Side Setback 20' 52.2Z55.2' 52.2'130' -Min Min Rear Setback 230.3' 53' Building Coverage (13 090sf 257.max (1096sf) 2.19 (2104sf) 4.07. 0 co why Ln 0 Z' Locus A oc Rd 0-\ S80*02'30p) N32;7.,30, LOCATION MAP LO \V ...... .......... Asses. Map ID: 124128 Title Ctf.-20JO47 Existing .................. Septic System r- -7 LOT 10 CB/DH Deed DOC: 124,344J ' (DWCP #14-92) 0 . Location per LCP 11785—C L. C. Plan: 11785— C E-4 Iw j As–Built O Lots 10 & 11 'Po �11c' 0 /z Owner of Record: Lots 10 & 11 Tanya Z. Noteva 52,360 SF Z' Cy House __J -\VZ- 1.2 Acres... TOF 0 C) Existin 9 141 ...... .... . . ................. El 39.5 ....... /6) .... ..... . Property Area Total= /0 64.7' 52,360sf Dome /Z 4" Area within Zone H= Charcoal Vent 23,500sf .. ............. 1' Above grade C� '00 ............... BH . .......... WP -Zone II ............ ............. 0 _\Wp__Zone 11 Ulrn*lt Proposed Exist. oosf± within .,Zone Septic C6 OF 4fq8.Sd .. ............... Gravel 23,5 System 0 DANfELyG Parking /DH P. C OTE .......................... r TH 2 V Proposed IVIL AIJ . I I I r ...... NO. 46 53 C" 0 Garage Q)c f 1 Propos '12' & Apart. N ....... —53' Proposed UP guy . ............ diDriveway 's4r'-q� 19 0 0 G/ST CB DH . ...... 0 Pr*16pb'sej'- 28 8/ONA -Wa—ter-fe c Car Z14 0 BENCH MARK 0 5' OVERDIG TO C2 -LAYER . ...... 7� Catch I * 0 . ...................... It Top Concrete Bound RECEIVE 552.70, -�NSPEC TION REQUIRED 0 Basin Is. QF. El. 35.8 80*02',30), W L ........................ 06 FEB 2 7,2017 _j 30, MICH S W=Al nrPT LOT 11 LAD 32 LCP 11785-C o No. 3 60 MgRAN ENGINEEC.,LLC RING ASSO 30 -Ess\o 508-432-2878 941 MAIN STREET (RTE 28), HARWICH, MA I/ PROPOSED GARAGE LOCATION & SEPTIC DESIGN PLAN ........... ... -Yarmouth Health r e C 3/DH ,Prepared For: Tana & Dimitor Noteva SCALE: I"= 30 T D 30 60 90 In" -!�r 4 /./ 984 WEST YARMOUTH ROAD YARMOUTH PORT, MA 0 Name Date _F "— _5� mm� I Sh t: 1 of2 PROJECT. I6— 6—,94 SCALE: 7 3 ATDATE: 2117117 � �.a I°- --� T.O.F. 12' ELEV. 33.0 ELEV. 28.7 PI�10" - 14"�. ELEV. 29.0 1500 GAL. SEPTIC TANK H-20 ACCESS COVERS BROUGHT TO WITHIN 6" OF FINISHED GRADE FA GAS 4" Dome Charcoal Vent 1' 3' Max Cover Above SAS c0000c000cc �0000 000000 cc000c000ec coon oo ocoo cc c000ccocc 00000c000c, D—BOX 1 5'endse, 2-500 Gal Chambers _11.5'ends� H-20 2.6 sides 10' x 20'1 x' 2' Deep2.6'sides 500 Gal. Chamber & Stone SYSTEM PROFILE LEACHING FACILITY Not to sca le H-20 SYSTEM DESIGN *23,500sft of Lot Area is within a Designated Public Wellhead Zone—II Design Flow: 2 bedrooms @ 110 gal/day = 220 gal. Septic Tank: 220 gal. x 200% = 440 gal. 0-3" Use: 1500 Gal. Septic Tank (Title 5 Min.) Leaching Facility: 10'x20'x2'deep Chamber and Stone SAS Bottom: 10'x 20' x 0.74 Gal/SF= 148 Gal Sides:i10�0')x2'x2x0 74Gal/sf= 88 Gal Loamy Med/Fine Sand TOTAL = 236 Gal. Note: Garbage disposal is not permitted with this design. SEPTIC SYSTEM NOTES filter fabric or 1/8" to 1/2" double washed stone ( 3/4" to I V2" double washed stone ELEV. 26.0 10' i Elev. 16.0 Btm. T.H. 1 SAS CONSTRUCTION DETAIL 500 GAL. LEACHING CHAMBER, H2O ------------------------------ f 6 2 . Double Washed Stone ; ' 10' 0 O ; � 4.8' Double Washed Stone 2.6' L----------------------------1- 1.5' ' 8.5' --�— 8.5' 20' 1) ALL COMPONENTS ARE TO MEET TITLE 5 MATERIAL & CONSTRUCTION REQUIREMENTS. 2) SYSTEM COMPONENTS ARE TO BE SET ON A STABLE, COMPACTED BASE. 3) DISTRIBUTION BOX EXIT LINES ARE TO BE SET LEVEL FOR THE FIRST 2'. 4) UNSUITABLE SOILS ARE TO BE REMOVED (Down to C3 Layer), BELOW AND FOR 5' AROUND THE LEACHING AREA AND REPLACED WITH TITLE -5 FILL SOIL. , 5) COMPONENTS ARE TO BE WITHIN 3' OF FINISH GRADE & ARE TO HAVE A MINIMUM OF 1' OF SOIL COVER. ACCESS COVERS ARE TO BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. Sh t: 20 f2 *Remove 27. 1— *Remove 26.6 TEST HOLE I EI. 31.0 Depth Horizon Texture Color Other 0-3" 0 Organic 3-9" A Loamy Sand 10YR4/2 9-18" B Loamy Med/Fine Sand 10YR4/4 VF 18-38" C1 Loamy Med/Fine Sand 2.5Y6/6 VF 38-46" C2 Sandy Loam 2.5Y5/4 Friable 46-180" C3 Fine Sand 2.5Y6/4 VF b1tm Ll. 75.0 No Groundwater Found TEST HOLE 2 EI. 31.8 Depth Horizon Texture Color Other 0-3" 0 Organic 3-12" A Loamy Sand 10YR4/2 12-34' B LoamyMed/Fine Sand 10YR5/6 VF 34-52" C1 Loamy Med/Fine Sand 2.5Y6/6 VF 52-62" C2 Sandy Loam 2.5Y5/4 Friable 62-120" C3 Fine .Sand 2.5Y6/4 VF tstm Ll. 27.d Date: 2/16/17 Performed By: Witness: No Groundwater Found Daniel Croteau, SE Philip Renaud, HA PERCOLATION TEST @ TH 2 24 GALLONS OF WATER IN LESS THAN 15 MIN. WITH LESS THAN 9" REMAINING, A DEPTH OF 81 INCHES IN C3 LAYER. DESIGN RATE: < 2 min./in.