HomeMy WebLinkAboutEngineered Plans - 2017CONVENTIONAL S.A.S.
FOR ILLUSTRATION ONLY -DO NOT INSTALL
A 10' X 45' LEACH FIELD
BOTTOM AREA = 450 SF
CAPACITY = 0.74 GPD/SF(450 SF) = 333 GPD
LOT 27
14,817± SF -
PARCIL ID: 39-309
33'
l00 4�-Rpp'aSEa S:W;�
26 O
100.68 + O
PROPOSED PLASTIC O 100.51 100,74
SEPTIC TANK BM
01,38
o PORCH
LO a 100,52
N EX. SEWER
u' INV. =98.94±
0EXI ST NG/ f
U) HOUSE(#54)
i
TOF=101.44± PORCH
`1100.76 I 1
X 10 0. 81
I X
O
a
X
0..
+ 100,71
100.76
130.00'
Its apt v»fWk for REPAIR Of SEI'1'1t SSV44IEM
; A;* .4 'to State and Local septi+ variances.
,W*r.. 0r10*Hh review and approval is requpred ±'qtr°
a
Vany,fwf, e: additi+ins/retroA�aijt,ns/iiileratiions .to
sewag,>e`facilities»n>€1/orsfructures/dweUi+�t�.
Yarmou h Hea(ih, department
A 'R. -V D r
100.60 I S 55'26'15" E
edge of 100.10
BEVERLY
S�Wf
edge of clearing
1-0�0
X
SHAD 99.91
V1,
S
""�TEXISTING CESSPOOLS
TO BE PUMPED, FILLED WITH
SAND, OR REMOVED
dQ SEE ALSO, NOTE 11
BENCHMARK
OUTSIDE COR./8OTT. STEP
EL. =101.38 (ASSUMED DATUM)
\
LEGEND
W
EXISTING CONTOUR
99,70F
10
10
-W
99.78
r
4
(9.14 W
00.59
-
TEST PIT
1
SHRUB
0
TREE
+ o'
z
GARAGE
100.4% lb
Cb a°
100,56
01,10.::.::.:::
/ + 99,85
ZE
,.
t 71
1 i
sz
�N
pavement
99,90
99,6 r`
.ROAD
PETER
MCENTE E
c1v1�
NO.35109
OWNER OF RECORD
OCALLAHAN, PATRICK J LIFE EST
OCALLAHAN, MARIE T LIFE EST.
77 SHIRLEY AVENUE
QUINCY, MA 02169
LOCUS MAP
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
-310 CMR 15.405(1)(h):
1) A 1' reduction to the required 5' separation between maximum
seasonal high groundwater and bottom of S.A.S., for 4' separatic
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. SUBJECT SITE DOES NOT LIE WITHIN A STATE REGULATED ZONE II.
14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
AS A PROPERTY LINE SURVEY OR FLOOD ELEVATION CERTIFICATION..
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
54 BEVERLY ROAD, WEST YARMOUTH, MA
Prepared for: D.A Brown, Inc. P.O. Box 145, Centerville, MA 02632
Engineering by: Surveying by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 206-17
12 West Crossfield Road 2854 Cranberry Hwy.
Forestdole, MA 02644 E.Warehom, MA 02538 DATE CHECKED SHEET NO.
(508) 477-5313 (508) 273-0377 7/12/17 P.T.M. 1 Of 2
LEGEND
--98--
EXISTING CONTOUR
x 98,98
EXISTING SPOT GRADE
99 PROPOSED CONTOUR
-W
EXISTING WATER SVC.
-G
EXISTING GAS SVC.
(9.14 W
OVERHEAD WIRES
TEST PIT
BENCHMARK
SHRUB
0
TREE
PETER
MCENTE E
c1v1�
NO.35109
OWNER OF RECORD
OCALLAHAN, PATRICK J LIFE EST
OCALLAHAN, MARIE T LIFE EST.
77 SHIRLEY AVENUE
QUINCY, MA 02169
LOCUS MAP
NOT TO SCALE
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
-310 CMR 15.405(1)(h):
1) A 1' reduction to the required 5' separation between maximum
seasonal high groundwater and bottom of S.A.S., for 4' separatic
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. SUBJECT SITE DOES NOT LIE WITHIN A STATE REGULATED ZONE II.
14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
AS A PROPERTY LINE SURVEY OR FLOOD ELEVATION CERTIFICATION..
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
54 BEVERLY ROAD, WEST YARMOUTH, MA
Prepared for: D.A Brown, Inc. P.O. Box 145, Centerville, MA 02632
Engineering by: Surveying by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 206-17
12 West Crossfield Road 2854 Cranberry Hwy.
Forestdole, MA 02644 E.Warehom, MA 02538 DATE CHECKED SHEET NO.
(508) 477-5313 (508) 273-0377 7/12/17 P.T.M. 1 Of 2
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL.=98.7
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S. DECK
SEPTIC TANK PROPOSED S.A.S.
INSTALL RISERS & COVERS OVER INLET & PROPOSED D, -BOX INSTALL 1 INSPECTION PORT(MIN.)
OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & WATERTIGHT AT END OF S.A.S. BEDROOM BATH KIT.
T.O.F.=101.44± COVER SET TO 6" OF GRADE DIN. RM.
F.G. EL.=100.6E F.G. EL.=100.5± F.G. EL.=100.5± HALL GARAGE
EXISTING `F.G. EL.=100.5±
r �( MAINTAIN 2% GRADE (MIN.) OVER S.A.S.
LOM LIV. RM. PORCH
L = 13'7
u•LD.DA
@S=1% (MIN.) L = 6 L = 6' INSPECTION PORT
4"SCH40 PVC @ S=1% (MIN.) @ S=1% (MIN.) ONE (MIN.)
TOP OF TANK=99.35 4'SCH40 PVC 4"SCH40 PVC
,D" , 3„ ,4" s" 7.13° TO FLOOR PLAN
44" LIQUID LEVEL INVERT
I
ADD INV.=98.26 r`
GAS BAFFLE INV.=98.43 PROPOSED 3 ROWS OF 7 UNITS AT 5.0'/UNIT = 35.0' S.A.S.LAYOUT _ 35>:,��-- '
BOTT. OF TAN K=94.81 INV.=98.49 D -BOX SOIL ABSORPTION SYSTEM (PROFILE)
PROPOSED 1500 GALLON SEPTIC TANK INV.=98.20SHED
ROpOSED S•�,�.►
INFILTRATOR IM1530 GALLON PLASTIC TANK 00 p
INV.=98.74 ESTABLISH VEGETATIVE COVER U! '
BACKFILL WITH CLEAN NATIVE OR
PERC SAND TO TOP OF CHAMBERStX
�J6
CONNECT TO EXISTING SEWER
AT HOUSE, INV.=98.94 BREAKOUT=TOP ' ;�,.°` C46,-10
TOP ELEV.=98.68 ' �N S -0.
INV. ELEV.=98.20 ry'
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BOTTOM ELEV.=97.60-' PORCH
INVERTS, PRIOR TO INSTALLATION. 4' MIN. ABOVE BOTTOM OF
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH=8.5'
TRUE TO GRADE ON A MECHANICALLY COMPACTED (WITH VARIANCE) EXISTING SUITABLE ! / BACK OF HOUSE
SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN HIGH G.W., EL=93.60 - MATERIAL
310 CMR 15.221(2). -
3) INSTALL INLET & OUTLET TEES AS REQUIRED. USE 3 ROWS OF 7 -ADS Arc 36 UNITS PER ROW WITH 63.5"
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE NO SEPARATION BETWEEN EACH ROW & NO STONE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
SEPTIC SYSTEM PROFILE TYPICAL SECTION 13
33.8"
DESIGN CRITERIA SOIL LOG
DATE: JUNE 17, 2017
NUMBER OF BEDROOMS: 2 BEDROOMS SOIL EVALUATOR: PETER MCENTEE PE(SE#1542) TOP VIEW
SOIL TEXTURAL CLASS: CLASS I WITNESS: AMY VON HONE RS HEALTH AGENT
so
DESIGN PERCOLATION RATE: <2 MIN/IN ELEV. TP DEPTH
END CAP END CAP
0"
DAILY FLOW: 220 GPD 99.7 A FRONT VIEW SIDE VIEW
DESIGN FLOW: 330 GPD LOAMY SAND END CAP
GARBAGE GRINDER: NO-S.A.S. IS NOT DESIGNED FOR GARBAGE GRINDER 10YR 4/2 REAR/TOP VIEW
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 99.1 7"
B NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW
TO MAY
.74 GPD SF DIFFERNGE SLIGHTLY WITHOUTNOTICE.
OACTUALRODUCT PROD CTE
TAIL / LOAMY SAND PERC APPEARANCE.
�r
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY 14"/32' 10YR 5/6 1' 4640 TRLEMAN BLVD ak
INFILTRATOR IM1530 GALLON PLASTIC TANK 96,5 38"LUUVI Arc 36 DETAIL
HILLIARD, OHIO 43026
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED C
ADVANCED DRAINAGE SYSTEMS. INC.
MED. SAND
USE 3 ROWS OF 7 -ADS Arc 36 UNITS WITH NO 2.5Y 6/4 PROPOSED SEPTIC SYSTEM UPGRADE PLAN
SEPARATION BETWEEN EACH ROW & NO STONE 93.6 ADJr G.W. r 54 BEVERLY ROAD, WEST YARMOUTH, MA
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) MA 02632
(Arc36 Units) 21 UNITS x 5.0 LF x 4.80 SF LF = 504.0 SF Prepared for: D.A Brown, Inc. P.O. Box 145, Centerville,
/ 91.7 STG. G.W. - 96"
TOTAL AREA = 504.0 SF Engineering by: Surveying by: SCALE DRAWN JOB. N0.
so.7 T 108 Engineering Works, Inc. JC Engineering, Inc. N.T.S. P.T.M. 206-17
STANDING G.W. AT 96" (EL.=91.7), INDEX WELL MIW-29, ZONE B 12 west Crossfield Road 2854 Cranberry Hwy.
WATER LEVEL=7.6 (MAY 2017), ADJUSTMENT=1.9' Forestdole, MA 02644 E.Warehom, MA 02538 DATE CHECKED SHEET NO.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(504.0 SF) = 373.0 GPD ESTIMATED HIGH G.W., EL.=93.6 (508) 477-5313 (508) 273-0377 7/12/17 P.T.M. 2 Of 2
PERC RATE: 2 MIN IN. "B" HORIZON