Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2017GENERAL NOTES: 1. ALL SEPTIC SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE, 310 C.M.R. 15.000, AND ALL APPLICABLE LOCAL BOARD OF HEALTH RULES AND REGULATIONS. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER PRIOR TO INSTALLATION. 3. EXISTING CONDITIONS SURVEY AND PROPERTY BOUNDARY PROVIDED BY TERRY WARNER, P.L.S., HARWICH, MA. ELEVATIONS BASED ON ASSUMED DATUM OBTAINED FROM A BENCHMARK AS NOTED ON PLAN. 4. THIS PLAN IS INTENDED FOR THE SEPTIC SYSTEM WORK DEPICTED ONLY AND IS NOT INTENDED FOR ANY OTHER PURPOSE. PROPERTY LINE INFORMATION IS APPROXIMATE ONLY. THE DESIGN ENGINEER WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 5. ZONE: RESIDENTIAL — R-40, APD AQUIFER PROTECTION DISTRICT. 6. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 7. LOCUS ASSESSOR'S PARCEL ID: 58-345 8. OWNER OF RECORD: BURKE, JOHN J. & JANICE L., 159 HARANTIS LAKE RD., CHESTER, NH 03036. LAND COURT DOC: 1173422. 9. THE LOCUS IS LOCATED IN FLOOD ZONE X AS SHOWN ON F.I.R.M. COMMUNITY PANEL NUMBER 250015 C0587J REVISED 16 JULY 2014. 10. NO PUBLIC SURFACE WATER SUPPLY OR PUBLIC GRAVEL PACKED WELLS WERE FOUND WITHIN 400' OF THE PROPOSED SEWAGE DISPOSAL SYSTEM. NO TUBULAR PUBLIC WELLS WERE FOUND WITHIN 250' OF THE PROPOSED SEWAGE DISPOSAL SYSTEM. 11. NO PRIVATE POTABLE WELLS WERE FOUND WITHIN 150' OF THE PROPOSED SEWAGE DISPOSAL SYSTEM. 12. CHANGES TO EFFLUENT FLOW OR CHARACTERISTICS, GRADING OR LANDSCAPING EITHER ON—SITE OR ADJACENT TO THE SITE OR FAILING TO PROPERLY INSPECT OR PUMP THE SEPTIC TANK MAY DETRIMENTALLY AFFECT THE FUNCTION OF THE SOIL ABSORPTION SYSTEM. 13. THE OWNER SHALL INSPECT AND PUMP THE SEPTIC TANK EVERY 2 YEARS. 14. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. Yarmou4HealthDepartment AVED ameDate I .B'C`EIV L''L 0 7 2017 HEALTH DEPT 4 s'r�Y+43q�� M TfEIRRV ANN, - £IP WARNEP No, 387�4 11 W O V r 0 10 20 SITE PLAN Pav�men t b to BROOK �P~� 40 FEET (, SAMUELJ.P. : JENSEN CIVIL N0.46058 ?—t LOCUS LOCUS MAP NOT TO SCALE LEGEND — 50 — EXISTING CONTOUR 50 PROPOSED CONTOUR — ErTic — ELEC. UTILITIES — w —WATERLINE — GAS — GASLINE TEST PIT LOCATION O O O SEPTIC TANK 4" SOLID SCHED. 40 PVC PIPE ❑ DISTRIBUTION BOX ------ 4" PERFORATED SCHED. 40 PVC F 7o CHAMBER PROPOSED SEPTIC UPGRADE Located at: 22 MIRROR BROOK ROAD W. YARMOUTH, MASS. Prepared for: JOHN J. BURKE 159 HARANTIS LAKE RD. CHESTER, NH 03036 Prepared by: SAMUEL JENSEN, P.E. P.O. Box 1141, Forestdale, MA 02644 774-327-0727 Scale: AS NOTED Date: MAY 22, 2017 Sheet No. 1 of 2 Rev. JULY 7, 2017 TOP OF FINISHED GRADE OVER FOUND. SEPTIC TANK = EL.=101.54 99.6 - 99.3 3" MIN. -99.04 INLET INVERT EL. = 96.90 -10' MIN. - THREE 20" MIN. COVERS (TYP.) -COVERS SHALL BE SET TO WITHIN 6" OF FINISHED GRADE WITH RISERS. 13" 2" MIN 3" MAX 14 INI 48 GAS I BAFFLE 3" MIN. OUTLET INVERT EL. = 96.70 �- 6" OF CRUSHED Kii t'ss> STONE PROPOSED 1500 GAL CONCRETE SEPTIC TANK LENGTH 10'-6" WIDTH 5'-8" HEIGHT 5' -8 - SEPTIC TANK NOT TO SCALE INLET INVERT EL. = 96.50 CONSTRUCTION NOTES: 1. ALL SEPTIC SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE, 310 C.M.R. 15.000, AND ALL APPLICABLE LOCAL BOARD OF HEALTH RULES AND REGULATIONS. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER PRIOR TO INSTALLATION. 3. THE DISPOSAL SYSTEM INSTALLER SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. 4. THE DISPOSAL SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN ON PLAN PRIOR TO CONTINUATION OF WORK. 5. PIPING SHALL CONSIST OF SOLID 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS UNLESS OTHERWISE NOTED. 6. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM UNLESS OTHERWISE NOTED. 7. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE STRUCTURES SHALL BE MADE WATERTIGHT WITH NON -SHRINK GROUT OR AS APPROVED BY THE DESIGN ENGINEER. 8. ALL STONE TO BE DOUBLE WASHED AND FREE OF ALL DIRT, DUST AND FINES. 9. ALL SEPTIC SYSTEM COMPONENTS SHALL BE CONSTRUCTED TO WITHSTAND H-10 LOADING UNLESS LOCATED UNDER PAVEMENT, DRIVES OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING UNLESS OTHERWISE NOTED. 10. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. FINISHED GRADE OVER D -BOX = 99.5 -PROVIDE RISER TO WITHIN 6" OF FINAL GRADE OUTLET INVERT EL. = 96.33 GEOTEXTILE FABRIC OR 2" OF J" TO I" DOUBLE WASHED STONE TOP OF S.A.S. EL. = 96.53 CLEAN SAND (BREAKOUT EL.) INLET INVERT EL. = 96.20 FINISHED GRADE OVER CHAMBERS = 99.5 - 99.3 SLOPE AT 2% MIN. OVER SYSTEM END CAPS INSPECTION PORT ALL WITH CAP AND VALVE g" MIN. I ROWS BOX TO GRADE 36" MAX( 95.53 Af I l \\_ /ff I (\\ /ff I I \\ I e'gv�h�,at, : 6" OF CRUSHED 8 STONE " 36 UNDISTURBED EARTH OR 11'-4" COMPACTED BACKFILL 5' MIN. UNIT SHALL BE 5 OUTLET. PROFILE ADJUSTED END VIEW INSTALL FIRST TWO FEET OF 36 QUICK4 PLUS STANDARD CHAMBERS GROUNDWATER OUTLET PIPES LEVEL. WITH NO STONE, 4 ROWS OF 9 EL. = 90.5 DISTRIBUTION BOX (H-20) SOIL ABSORPTION SYSTEM NOT TO SCALE NOT TO SCALE TEST PIT DATA: 0 SOIL EVALUATOR: Samuel Jensen. SE# 1928 15" DATE: May 18. 2017 PERC. RATE: <2 min./in. TOWN WITNESS: Philip Renaud 23" CLASS:A. EXCAVATOR: J. LeBoeuf INDEX WELL: MIW29 ZONE: A 311° INDEX: 7_6 ADJ: 1.3' 42" SHGW ELEV.: 90.5' PERC. 60" 102" DESIGN DATA: NUMBER OF BEDROOMS: DESIGN FLOW RATE: DESIGN FLOW: 115" 132" TEST PIT 1 Fill Loamy Sand 2.5Y4/4 A Massive; Very Friable B Loamy Sand 10YR 6/8 Massive; Very Friable; C Fine Sand 2.5Y 8/4 Massive; Very Friable 5 - 10% Gravel Redox. Observed Standing Water Observed 2 110 GPD/BEDROOM 330 GPD (CODE MIN.) SEPTIC TANK NEW 1500 -GALLON SEPTIC TANK REQUIRED = 200% OF DESIGN FLOW: 2 X 330 = 660 GAL PROVIDED: 1500 -GAL SOIL ABSORPTION SYSTEM 36 QUICK4 PLUS STANDARD CHAMBERS WITH NO STONE AROUND REQUIRED S.A.S. CAPACITY: 330 GPD MASSDEP APPROVAL FOR GENERAL USE: 4.73 SF/LF EFFECTIVE AREA = (36 UNITS)(4 LF/UNIT)(4.73SF/LF) = 681.1 SF PROVIDED S.A.S. CAPACITY = (EFFECTIVE AREA) (L.T.A.R.) = (681.1) X 0.74 = 504 GPD 90.3' 89.2' 87.8' yob SAMUEL J.P. 0 JENSEN No CIVIL9 LIVING DINING/ BREEZE - ROOM I KITCHENJ WAY GARAGE BEDROOM BATH 12" BEDROOM I ONE FLOOR BASEMENT UNFINISHED FLOOR PLAN NOT TO SCALE PROPOSED SEPTIC UPGRADE Located at: 22 MIRROR BROOK ROAD W. YARMOUTH, MASS. Prepared for: JOHN J. BURKE y 159 HARANTIS LAKE RD. CHESTER, NH 03036 Q Prepared by: SAMUEL JENSEN, P.E. P.O. Box 1141, Forestdale, MA 02644 774-327-0727 Scale: AS NOTED Date: MAY 22, 2017 Sheet No. 2 of 2 Rev. JULY 7, 2017