HomeMy WebLinkAboutEngineered Plan - Rev. 2017TOP OF FOUNDATION EL = 13.0 FINISH GRADE = 12.0 L 6' OF 3/4' TO - 1-1/2' DIA STONE BELOW TANK NOTE, ALL PIPE TO BE 4" DIA. PVC TIGHT JOINT WITH MINIMUM SLOPE OF 1/8" PER FT. MAP 43 PARCEL 38 HOWARD W. LOWEE c/o JONATHAN WOOD 20 10 0 PLAN 0 20 1 inch = 20 ft. CY GAS BAFFLE PROPOSED SEPTIC TANK PRECAST REINFORCED CONCRETE CAPACITY: 1500 GALLONS (H-20) MANHOLE AND COVER -MIN 24' DIA RAISE COVERS TO WITHIN 6' OF FINISH GRADE PROVIDE SLEE1 WATER SERVIG Zel EXISTING D—BOX NOTE- LINE(S) EXITING D -BOX MUST REMAIN LEVEL FOR 2'-C' BEFORE PITCHING DOWN TO LEACHING FACWTY SEPTIC SYSTEM PROFILE NO SCALE i i i I MAP 43 PARCEL 33 MICHAEL SHAY LOCATE AND PROTECT UND. ELECTRIC AT ' GARAGE SITE BENCHMARK: TOP OF CONCRETE BOUND EXISTS FINISH GRADE = 12t 32' EXISTING S.A.S. OBS. PORT BOTTOM EL=6.6 r GENERAL NOTES 1. ELEVATIONS REFER TO NAVD88. REFER TO THE BENCHMARK CONCRETE PROPERTY LINE MARKER ON NORTH LOT LINE, CONTACT CAPE COD ENGINEERING, INC. FOR ADDITIONAL ELEVATION INFORMATION. 2. PLAN REFERENCE: TOPOGRAPHIC SURVEY DATA PROVIDED BY SCHOFIELD BROTHERS OF CAPE COD, INC. SEPTIC SYSTEM PLAN PREPARED BY DARREN MEYER, RS ON FILE AT YARMOUTH HEALTH DEPT. 3. ALL SEPTIC SYSTEM CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFORM TO THE STATE SANITARY CODE, TITLE 5 AND TOWN OF YARMOUTH HEALTH DEPT. APPROVAL FOR THE TANK INSTALLATION AND "D" BOX CONNECTION. 4. THIS PLAN IS BASED UPON A ONE BEDROOM ADDITIONAL FLOW TO THE EXISTING SAS AS APPROVED FOR 445.2 GPD AS INSTALLED AND INSPECTED BY THE TOWN. 5. WATER SERVICE PIPE SHALL BE EXACTLY LOCATED. THE WATER SERVICE SHALL BE SLEEVED IN A CONTINOUS 4 IN. PVC PIPE SEALED WITH MORTAR AT EACH END WITHIN 10 FT. OF THE WATER SERVICE CROSSING. 6. REPLACE THE STOCKPILED SUBSOIL ("B" HORIZON) PRIOR TO ROUGH GRADING AND TOPSOIL APPLICATION AND LAWN SEEDING. LANDSCAPE IMPROVEMENTS SHALL BE AS DIRECTED BY THE OWNER 7. FULLY COMPACT ANY PIPE BED TRENCHES BENEATH DRIVEWAY AREAS. PROVIDE SUITABLE BASE COURSE PRIOR TO DRIVEWAY RESTORATION. 8. INSTALLER SHALL CONTACT ENGINEER AT TIME OF SYSTEM COMPLETION PRIOR TO EARTH COVERING FOR SYSTEM CERTIFICATION IF REQUIRED. 9. CONTACT ENGINEER IF ANY QUESTIONS OR DOUBTS ARISE REGARDING SOIL CONDITIONS ENCOUNTERED DURING CONSTRUCTION. 10. NO KNOWN WELLS EXIST WITHIN 200 FT. OF THE PROPOSED SEPTIC TANK OR EXISTING COMPONENTS. THE SITE IS SERVED BY TOWN WATER DESIGN DATA HYD. LOADING EXISTING DWELLING - 3 BEDROOMS X 110 GPDBR = 330.0 GPD DWELLING HAS AN EXISTING 1,500 GALLON SEPTIC TANK TO REMAIN PROP. ACCESSORY BUILDING -1 BEDROOM X 110 GPD =110 GPD TOTAL = 440.0 GPD SEPTIC TANK DESIGN ( ACCESSORY FLOW ONLY) 110 GPD X 200% = 220.0 GPD PROVIDE A 1,500 GAL. SEPTIC TANK — ST 1500 —11-10 EXISTING SAS DESIGN (PER EXISTING RECORDS) PERCOLATION RATE — LESS 5 MPI TOTAL LEACHING DESIGN CAPACITY = 445.18 GPD *THE DESIGN IS NOT SUITABLE FOR USE WITH A GARBAGE DISPOSAL UNIT Yarmouth Health Dep irtmeat ,--) �AP vED Dale L.V1iUJ NANTUCKET SOUND KEY MAP NO SCALE YARMOUTH, MA CHIZMAS.DWG k YYYa � yY RRCE VE6/ t „<� MAY 162017 a i HEALTH DEPT. I REV. MAY 15, 2017 — SHIFT SEPTIC TANK LOCATION TOPOGRAPHIC PLAN SHOWING PROPOSED ACCESSORY BUILDING AND RELATED SITE WORK AT 66A RIVER STREET, SOUTH YARMOUTH, MA ASSESSORS MAP 43, PARCEL 37 PREPARED FOR JEFFERY CHIZMAS 13 JONES ROAD MIDDLETON, MA 01949 OCTOBER 27, 2016 SCALE - AS NOTED PREPARED BY CAPE COD ENGINEERING, INC. ROBERT M. PERRY, P.E. P.O. BOX 1517 EAST DENNIS, MA 02641 TEL: 508-385-1445 CHIZMAS.DWG