HomeMy WebLinkAbout2017 Jun 08 - Email to Mike Aucoin vonHone, Amy From: vonHone,Amy Sent: Thursday, June 08, 2017 3:55 PM ' To: 'Mike Aucoin' � Cc: 'Patrick Sullivan' ! Subject: 5 Quail Road ; i Hi Mike- Just reviewed this plan and have a couple of issues that need to be addressed. �1. Effluent filter is needed in the tank outlet tee as required by Title 5 with pump systems. j �a2. The design calculations don't appear to be correct. 29 units x 5' long x 4.73sf/If=685.85 If 685.85 If x f 0.74 loading = 507.52 gpd. You have enough capacity for the existing house, however, your ; calculations reflect 30 units instead of the 29 units that are proposed. ' � 3. The final plans need a PE or RS along with the PLS stamp. � Please call or email with questions. I will need 3 revised, stamped plans for approval of the installation permit. ; � Thanks, Amy ; f i Amy L.von Hone, R.S., C.H.O. f Assistant Health Director Yarmouth Health Department 1146 Route 28 South Yarmouth, MA 02664 (0) 508-398-2231 X1241 � (F)508-760-3472 f � avonhone(c�varmouth.ma.us ` � � i � f k � f � f I 1