Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2017L LEGEND `--�-� PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W- EXISTING WATER SERVICE s TEST PIT 1"=20' GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY MUNICIPAL WATER. EXISTING WATER SERVICE TO BE RE -LOCATED AND SLEEVED AS SHOWN. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING (IN PROP LEACH FOOTPRINT) TO BE CRUSHED, PUMPED AND REMOVED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 0 1/8 -/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 3.68 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 18. PLACE 40m1 POLY LINER AROUND ENTIRE LEACHING INSIDE OF PROPOSED RETAINING WALL, FROM ELEVATION 8.5-4.5 19. PLACE GEO-GRID UNDER LEACHING AS SHOWN. PROP. 2,000G 2 -COMP TANK (1500G/500G) Yarmouth Health Department PROVED Date SOUTH YARMOUTH LUUUS MAP LOCUS INFORMATION TITLE REF: 100/069 TITLE REF: 1748/308 PARCEL ID: MAP 25 PAR. 178 FLOOD ZONE: "AE11" COMMUNITY PANEL: 25001CO589J DATED:07/16/14 AREA: 0.20 ACRES SEPTIC SYSTEM CP REPAIR PLAN U' LOCATED AT: 138 OCEAN AVENUE SOUTH YARMOUTH, MA PREPARED FOR MESSIER/CALDWELL MAY 30, 2017 REV: JULY 14, 2017 OF A R y✓+ N j No. 1140 \ si �N►TAR�P� N MEYER & SONS INC. P.O. BOX 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com survey by: Weller * Assoc. SHEET 1 OF 3 697 G.0 5.4 99.99' I G.I G.7 I 5.9 � i 11 W 00 I , I I 10 � I zI I I W I T. O. F. @ EL' . 7.2 \ I I , G. I _ SERVICE L- G.2 ' WATER sERViC� ~-----�-' I U I----- I TH#1 I I_ I ------------------� I LOT 28 i 8,712± S.F. I (0.20± AC.) ---- -3200' I G.I 5'.G G.I O PROP. SOIL T13M = EL. G.25(NAVD) REMOVAL PROP. GEOGRID FOOT PRINT PROP. TIMBER RETAINING WALL TOP OF CONC. 13ND. (SEE NOTE 17) (SEE NOTE 19) (SEE PAGE 3) Yarmouth Health Department PROVED Date SOUTH YARMOUTH LUUUS MAP LOCUS INFORMATION TITLE REF: 100/069 TITLE REF: 1748/308 PARCEL ID: MAP 25 PAR. 178 FLOOD ZONE: "AE11" COMMUNITY PANEL: 25001CO589J DATED:07/16/14 AREA: 0.20 ACRES SEPTIC SYSTEM CP REPAIR PLAN U' LOCATED AT: 138 OCEAN AVENUE SOUTH YARMOUTH, MA PREPARED FOR MESSIER/CALDWELL MAY 30, 2017 REV: JULY 14, 2017 OF A R y✓+ N j No. 1140 \ si �N►TAR�P� N MEYER & SONS INC. P.O. BOX 981 E. SANDWICH, MA 02537 PH. (508)360-3311 fax (774)413-9468 meyerandsonstitle5@gmail.com survey by: Weller * Assoc. SHEET 1 OF 3 697 T.O.F. EL.=7.20 PROPOSED TANK INSTALL RISERS W/IN 6" OF FINISH GRADE EL6.40± r6.20± EL.5.14 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS PUMP CHAMBER D -80X INSTALL RISERS to FINISH GRADE INSTALL RISERS W/IN 6" OF FINISH GRADE 6.20± ( 10" I " 50OG PA' TEE'S ARE TO BE COMP. A INV.= 4.09 4" SCH 40 PVC ••••• 1,5000 GAS Exist. InveCOMP. BAFFLE (SEE DETAIL INV.= 4.45 w/ FILTER BELOW) M. mk PROPOSED 1,500/500 GALLON 2 -COMPARTMENT SEPTIC TANK NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. 2) TANK/PUMP CHAMBER, AND D -BOX SHALL BE SET TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE AS SPECIFIED IN 310 CMR 15.221(2). 3) INSTALL PVC INLET/OUTLET TEES IN SEPTIC TANK AS REQUIRED. 4) GAS BAFFLE W/ FILTER TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 4" SCH 40 PVC ® S= 1% (MIN.) INV.= 3.84 F.G. EL: 9.75± INSTALL SANITARY TEE INV.= 8.3J D -BOX TEE SHALL NOT EXTEND BELOW FLOW UNE (USE DB -5 W/BAFFLE) FINISH GRADE=9.25 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA L=12'(MAX) 4" SCH 40 PVC 0 S= 1% (MIN.) 8.20 .oA OF o D R EN M. - M YE o f, 'QE6/STEL YNIT0,0 SEPTIC SYSTEM PROFILE N.T.S. INSTALL 1' PVC CONDUIT TO HOUSE FOR HARING TP- 1 WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM PROVIDE WATERTIGHT CONCRETE RISER FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON WITH SECURED COVER TO GRADE CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED HOISTING CABLE 7x19 STAINLESS STEEL BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE 1/8" DIAMETER. / 1,760 LB. STRENGTH. WATERTIGHT B 2"BALL VALVE w/ UNIONS SCH. 80 PVC PC INV.(OUT)=3.84 GEORGE FISHER CO. MODEL NO. 560 OR EQUAL 10YR 5/8 2"SCH. 40 DISCHARGE TO D -BOX (USE PRESSURE FITTINGS) ALARM ON EL: 1.17 29" PERC 0 2.27 2"SCH. 40 TEE w/ CLEAN-OUT CAP PUMP ON EU 0.91 SAND PROVIDE 1/4" WEEP HOLE IN DISCHARGE PUMP OFF EL -0.59 16" 2.5Y 7/4 PIPE FOR SELF -DRAINING FORCE MAIN 13. BALL CHECK VALVE SCH. 80 PVC BOTTOM OF INT. P.C. EL. -0.16 100 P.S.I. FLOWMATIC MODEL No. 208S PROVIDE 2- WADE ANGLE FLOATS: 2" SCH. 40 PVC DISCHARGE PIPE FLOAT NOA: PUMP ON/OFF (BARNES 073618 OR EQUAL) FLOAT NO.2: ALARM ACTIVATION (BARNES 073612 OR EQUAL) BARNES SEV412 PUMP .5 H.P. 115 V VOR 2" DISCHARGE PASSING 2" SOLIDS EQUAL NOTE: SEPTIC TANK AND PUMP CHAMBER TO BE FACTORY WATERPROOFED AND SEALED NTH THOROSEAL OR EQUAL. PUMP & ACCESSORIES AVAILABLE AS A UNIT THROUGH WIGGEN PRECAST CORP., BOURNE MA. (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WILLIAMSON ELECTRIC (781) 444-6800 PUMP DETAIL BUOYANCY CALCULATIONS 2.000 2 COMP -SEPTIC TANK uplift: 12' x 7' x 4 x 62.4 = 20,966.4 lbs ground cover: 12' x 7' x .75 x 120 = 7,560 lbs empty tank: 16,000 lbs groundcover + empty tank > uplift: 7,560 + 16,000 = 23,560 lbs > 20,966.4 lbs TANK BUOYANCY CHECK O.K. DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 8 CYCLES/DAY (SAND) 330 = 8 = 41.25 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 41.25 GAL/CYCLE _ 125 GAL/FT = 0.33 FT/CYCLE (4") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: INV. EL:4.75 - ALARM ON EL: 2.08 =2.67' STORAGE PROVIDED = 2.67' X 125 GAL/FT = 333.0 GALLONS 3.3" TO INVERT - MIN, COVER OVER S.A.S. = 9" TWO INSPECTION PORTS(MIN.) 3 ROWS OF 8 UNITS AT 4.0'/UNIT = 32.0'/ROW (see note 18) PAGE INV. EL.=8.07J SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER �BACKFILL WITH CLEAN PERC SAND ,, TO TOP OF CHAMBERS BREAKOUT=TOP ELEV.=8.46 INV. ELEV.= 8.07 BOTTOM ELEV.= 7.79 5' MIN. ABOVE BOTTOM OF m )� T.P. EXCAVATION OR G.W. (5.05' PROVIDED) ADJ. GROUNDWATER EL.=2.74 - SOIL LOG DiATE: MARCH 2, 2017 SOIL EVALUATOR: DARREN M. MEYER, R.S., WITNESS: A. VONHONE, YARMOUTH Elev. TP- 1 Depth 6.10 A 0" LOAMY SAND 10YR 4/1 5.18 11" B LOAMY SAND 10YR 5/8 3.68 C 29" PERC 0 2.27 MEDIUM SAND 2.5Y 7/4 -0.82 83" PERC RATE <2 MIN/IN. (-Cl- HORIZON) GROUNDWATER OBSERVED AT 62" EL. .94 WELL: MIW-29, ZONE A, LEVEL 8.4, ADJ 1.8' ADJUSTED GROUNDWATER ELEV. 2.74' IMM PLACE LEO -GRID I UNDER LEACHING 2.83' ON TOP OF EFFECTIVE WIDTH = 3 x 2.83' = 8.49' EXIST. MATERIAL USE 3 ROWS OF 8 INFILTRATOR QUICK 4 PLUS STD LP (3.3" INVERT) UNITS -NO STONE TYPICAL SECTION KM DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) SEPTIC TANK/PUMP CHAMBER: 330 gpd x 200% = 660 gpd USE 2 -COMP 2,000G TANK (1,50OG/500G) LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. DISTRIBUTION BOX: (3 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 3 ROWS OF 8 - INFILTRATOR QUICK 4 STD LP (3.3" INVERT) UNITS WITH NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 138 OCEAN AVENUE, _ Prepared for: Design and Site Plan by: MEYER & SONS, INC. PO BOX 961 EAST SANDW/CH, MA 02537 508-362-2922 SOUTH YARMOUTH, MA vlessier Caldwell SCALE DRAWN DATE N.T.S. DMM 05/30/17 REV. DATE SHEET NO. 07/14/17 2 of 3 2% GRADE y — — FINISH GRADE ELEVATION 9.75-8.50 TOP OF CHAMBER EL. 8.46. .' Ue,.s: ..tee M r'�: ..�e'♦� r•.e �.•��,♦A r�?: ♦.��'y • .;. ,.• ,�e !� : w�•••v� ! Y` w•� •v 4': '' �: -••►A.�i � �•. v�.♦i' r••..I Aa ;s: �'.•v♦ 'e • ; Y , da ,a . r� • � s: :' • r r'� • • °• • Vis' ♦ . r ' e. ' �,a v • , : ' A.' �s � ♦ .. '• '!. ' s �. � ae,.•: ��� � il�.r q,�� �'e-��.� �.♦�y: !•�vs:i y' w"..ia� Al: r•J.v .a e• �•v ,a vvsL.vd.a=!e•a•i:v'.A.v: ::v 0a.vv'�.PIa •%:, �v i°eR '• °!f 40ml Poly Liner (around entire leaching at edge of soil removal) �� OF o DA' N� ' . 140 G/ST ' SgNITAR�P� 14 El. 8.5 6" x 6" (30 year) Pressure Treated Railroad Ties -- Stagger Joints and Connect with 12" Spikes Step R.R Ties in 1/4". — EL. 6.1 — — Proposed Grade — -- BOTTOM EL. 5.1 — 2'x 1/2" REBAR @ 4' ON CENTER