Loading...
HomeMy WebLinkAboutEngineered Plans - 2017COVERS TO BE WATERTIGHT AND SEPTIC SYSTEM PROFILE Flaherty Environmental Services TOP OF FOUNDATION BROUGHT TO WITHIN 6" OF FINAL GRADE (not to scale) EL. 54.U' CLEAN SAND INSP. PORT W 3" OF GRADE P. 0, Box 81 EL. 56.0' 2" of If to ,I." DOUBLE WASHED EL. 54.0' Yarmouth Port, MA 02675 PEASTONCOR GEOTEXTILE 774.994.1166 4" CAST IRON or EQUIVALENT FILTER FABRIC MIN. PITCH 1/4" PER FOOT 4' 4" SCHEDULE 40 PVC IPE 4" SCHEDULE 40 PVC PIPE . ', • VENT (IF REQUIRED) 'to be level FLOW LINE (first EL. 51.1'1, ri 13' (6%) 9V 0?0002 010 0z 010 0;0;0606Q6 0 0 11 EXIST. ;0 E 0 000 ogogog0000 0 0 0 000 0 C OOOOC 000 00000C 0 00 'IST, EL. 51.0' 0 00, • EL. 50.03' 0,0 000000000 0 000 000 2.0' 0 0 ocl '00 0 0 y 00000000 , 000*0 20 M 000 OOOOC 50.2" 0000*600Z 0 0 0C EL. EL. 50.01 o-,, 000 .0 0 H-20 —100 M 00 000 00� 0 0 0 1[ 000 -0- 0- -0-0 -1 0 0 0 EL. 48.0' 0 GAS BAFFLE 0 000 0 0 00 0 000 'A (D -Box) - SOIL ABSORPTION SYSTEM 6" CRUSHED STONE OR (2) 500 GALLON H-10 CHAMBERS MECHANICALLY COMPACTED .01 1500 GALLON SEPTIC TANK WITH 4' STONE AROUND IN A - to 1;" DOB (DATUM.: ASSUMED) 4" ULE WASHED STONE 12.83'X 25'X 2' CONFIGURATION �El-, 44.0' BOTTOM OF TEST HOLE EL. 44.0' LOCATIONMAP SI'(1PPER I, /VSUSGS ADJUSTMENT: N/A GNO TH GROUNDWATER ELEV: N/A BENCHMARK: TOP OF FNDN EL. 56.. LOCUS LOT 46 14,600 SF± 50 MAP 115 LOT 187 52 OF MAS,5�. White Rock Rd. gC < EDWARD M 54 co STONE o No.289 o NTS EXISTING Q/ TE AA OF41/4 — Z 3 BR Co 50 DWELLING GARAGE C- F 10, Q ko N 21 PATIO ru 4� CAUTIO I UNDERG UND UTILI IES1 IST N1 A 37,8' Yarmouth Health Department � l E I T, SAS A A 0 E*JS-T-, S.T. tPPMED DATE. 712912017 [REVISED" Date ams me 0 SITE AND SEWAGE PLAN TH-1 116,37' FOR 52 B & B EXCAVATION, INC./ 54 101 SOLANGE NUNES 45 SKIPPER LANE SCALE: 1" = 30' YARMOUTH PORT, MA REF.- PB 987 PG 149 PAGE 1 OF2 GENERAL NOTES 1, ALL PRECAST COMPONENTS TO BE H-10 RATED UNLESS OTHERWISE SPECIFIED. DISTRIBUTION BOX(ES) AND ANY COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE GRINDER. 3, MUNICIPAL WATER IS AVAILABLE. 4, ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS, 5, INSTALLERICONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITY, 6, INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. 7, ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH, 8, FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000 UNLESS SHOWN PER PLAN, 9, ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND, 10.ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11.ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT. 12.NO KNOWN WETLANDS OR WELLS WITHIN 100 FEET OF PROPOSED LEACHING. 13. THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES. 14,LOT IS SHOWN AS ASSESSOR'S MAP 115 LOT 187. 15.LOCUS PROPERTY IS LOCATED WITHIN AN AQUIFER PROTECTION DISTRICT (ZONE II). DESIGN CAL COLA TIONS SYSTEM DETAIL Flaherty Environmental Services P. 0. Box 89 Yarmouth Port, MA 02675 NUMBER OFACTUAL BEDROOMS 3 774.994.9166 GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (110 GALA 330 GAL✓DAY 5' REMOVAL REQUIRED SEPTIC TANK CAPACITY 660 GAL, SIZE OF SEPTIC TANK SOIL CLASSIFICATION DESIGN PERCOLATION RATE EFFLUENT LOADING RATE LEACHING AREA (2)x(25.0'+12.83)(2) = 151 SF 25.0'x 12.83' = 320 SF 471 SFx 0.74 = 348 GPD 1500 GAL. (EXISTING) I 1 <2 MIN./INCH 0.74 GAL./DAY/FP USE (2) 500 GALLON H-10 CHAMBERS WITH 4' STONE INA 12.83' X 25' CONFIGURATION AS DIAGRAMMED RESERVE LEACHING CAPACITY N/A SOIL EVAL DATION TEST HOLE #1 Evaluator- David D. FlahertyJr., RS, REHS SE#2755 BOH Witness: Phil Renaud Date: July 26, 2017 TH-1 ELEV. 54.0' 0" - 14"I F/LDA LS 10YR 312 14"-35" IB LS 10YR 516 35" - 120" 1 C MS 2.5Y 615 G.W. ELEV. N/A BOTTOM TH-1 ELEV. 44.0' 52" EL. 49.7' / certify that on November 12, 2002, l have passed the examination approved by the Department of Environmental Protection and that the above analysis has been performed by me consistent with the required training, expertise, and experience described in 310 CMR 15.018(2). " 25' (NTS) �LZN OF `a oma'/ DAJ "gST�r' `�AIVITFlRIP � . SITE AND SEWAGE PLAN FOR B & B EXCAVATION, INC./ SOLANGE NUNES 45 SKIPPER LANE YARMOUTH PORT, MA PAGE 2 OF2