Loading...
HomeMy WebLinkAboutReview Checklist � � ��� � � Towlv oF Ya�ou•rH _ �,�',,�-��--�� ' SEWAGE PLAN REVIEW CHECKLIST _ �' ���'�7� �� . Location: A.M._�_ Lot� Zone of Contribution: In�O _ Acreag�`� ��1 � Commercial: Residential: �..� Street: � /� Village: Floor Plan: `� #Bedrooms:�_ Owner: S Insta.11er: Address: � Phone: Phone: ..-, Builder: Engineer: Address: Phone: '- - Phone: � � � �� • � t � N/A YES NO 1.Re uired#of copies received 2.Date of soils e�.m and ercolation test not older than 2 ears �/ 3.4-5 ft of naturall occurrin ervious material,above water table Z.,.,--•'` 4.Founda.tion 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: (;,,.�'' 6.Benchmark indicated and shown-NGVD if near wetlands t,j�' 7. S tic tank minimum 10 ft from foundation, deck Var.: 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft sla.b Var.: �/ 9.Leaching minimum 100 ft from wetlands Var.: •----`� 10.Leachin minimum 150 ft from drinkin welU25 ft irrigation well Var.: �---- 11.Tank/leachin minimum 10 ft from ro erty line Var.: - 12. S stem meets all other setback r uirements Var.: ' 13.Uses adjustment for maximum hi oundwater Var.: - ,' 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: s..--'' 15. S stem not in to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable L..-�'' 17. S stem meets slo e r uirements-min. 1/8", 1/4" referred =�,,,r.---' 18. S stem meets breakout re uirements PVC liner: Wall: 19. S ecified tee sizes are pro er, gas ba$le on outlet tee �-� 20. Sewage is under 10,000 for arcel �/" ' 21.No arba e dis osal �--� ; 22. S stem ad uatel sized for its intended use �---�' 23.Minimum 6"stone or com acted below tank and dbox �,�..- 24.Manhole covers within 6"of ade, um chamber cover to ade 25.Ins tion on plastic chambers/leach field ' 26.Electrical ermit for um cha.mber/S arate meter for du lexes °�--� 27.Pump system-2" line,wee hole,check valve,tee in dbox,pum size �- 28. S tic tank/ ump chamber to be facto wa roofed �' 29.Vent rovided if leaching below 3 feet,under driveway/ arking .�,,,. 30.Buoyancy calcula.tions for tank/ u chamber �„�.-� 31.En ' eer to ins ect and c ' soils: wall: commercial: �--�'' 32.Engineer/Re 'stered Sanitazian and Land Su.rve or s/si ture ,��' j 33.H-20 loading is subject to vehicular traffic, oundwater ; 34.Title V A lication and ermit fee,insta.11er si ature ; 35.Founda.tion footin min. 2 feet above ad'usted ound water for new house ' 36.De,ed Restriction r uired max. #bedrooms: max.flow: d _�--- ! 37.Check area lots for oundwater/Label groundwater in Assessor'.s Ma , � Plan reviewed by: �,03,0� '