Loading...
HomeMy WebLinkAboutReview Checklist I � �/ I�/ ',I / ���!/`�'C. �1�-�� _. � � ��f . � l� TOWN OF YARMOUTH � �, ; SEWAGE PLAN REVIEW CHECKLIST �C��- � . Location: A.M. to� Lot �� Zone of Contribution: In�Out Acrea.ge � � � Commercial: Residential:�Ll� Street: _ Village: � Floor Plan: #Bedrooms: � Owner: Installer: Address: Phone: " '� � Phone: �t� c� �(�i- c�' t��°��ir(/�' � Builder: Engineer: � � Address: Phone: -- '- i Phone: �'� �./ � �. f �� �'�. �� �'J' N/A YES NO 1.R uired#of ies received �� 2.Date of soils exam and ercolation test not older than 2 years ; 3.4-5 ft of naturall occurrin ervious material,above water table ��--'' � 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Vaz.: ✓" 5:Water line 10 ft from septic com onents Var.: �-''' 6.Benchmark indicated and shown-NGVD if near wetlands t,i.,� 7. S tic tank minimum 10 ft from foundation, deck Var.: � 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: - 10.Leachin minimum 150 ft from drinkin welU25 ft irri tion well Var.: 11.Tank/leaching minimum 10 ft from r line Vaz.: 1..�% ' 12. S stem meets all other setback r irements Var.: ' 13.Uses adjustment for maximum hi groundwater Var.: � �� 14.Leachin set 4-5 ft above adj.water or bottom est Var.: 15. System not in to or subsoil(A,B horizons) 5'remova 16.Pro osed contours are suitable �-�' ? 17.S stem meets slo e r irements-min. 1/8", 1/a" eferred I 18. S stem meets breakout r uirements PVC liner• �' all: �.,->> • 19. S ecified tee sizes are roper, as baffle on outlet tee ' 20. Sewa e is under 10,000 d for arcel i 21.No arba e dis osal ` � 22.S stem ade uatel sized for its intended use ; 23.Minimum 6"stone or com acted below tank and dbox �.�� i 24.Manhole covers within 6"of ade, um chamber cover to grade 25.Ins ection ort on plastic chambers/leach field ; 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2"line,weep hole,check valve,tee in dbo�pum size 28. S tic tank/ um chamber to be factory wa roofed 29.Vent rovided if leachin below 3 feet,under driveway/ arking 30.Buoyanc calculations for tank/ ump chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.En 'neer/Registered Sanitarian and Land Surve or stam s/signature 33.H-20 loading is sub'ect to vehicular traffic, groundwater 34.Title V A lication and ermit fee, installer si ture 35.Foundation footin min. 2 feet above ad'usted ound water for new house ' 36.Deed Restriction r uired max. #bedrooms: max. flow: - ; 37.Check area lots for oundwater/Label oundwater in Assessor's Ma � Plan reviewed by: �03�03