Loading...
HomeMy WebLinkAboutEngineered As-Built PlanLOCUS MAP SCALE: N.T.S. N/F SULLIVAN � MAP 68 LOT 163 #342 LONG POND DRIVE AS -BUILT TIE DISTANCES ST IN ST 0 1 2 3 4 INSP PORT 5 INSP PORT 6 iRMBERT W. CROWELL P.E. 1 CERTIFY THAT THIS PLAN CONFORMS TO TITLE 5 AND THE YARMOUTH B.O.H. REGULATIONS. PUMP TO BE EQUIPPED WITH AN ALARM LOCATED IN THE BUILDING WHICH IS POWERED BY A CIRCUIT SEPARATE FROM THE CIRCUIT TO THE PUMPS. CHILD PROOF COVER WATER TIGHT 24-30" DIA. JUNCTION BOX ACCESS MH TOP OF FDN 21.2 -PVC ELECTRICAL PIPE FLOAT HANGER 2"TO 4" TO PUMP CONTROLS XP% IN BUILDING DETACHABLE FLANGE „ POLY PROPELENE LIFTING LINE EXISTING BUILDING SEWER M, PROP.1500 GAL 4" SVC PIPE f FLOAT SWITCHES 2" F• SEPTIC TANK (CH. 40) -BRING RISERS TO WITHIN 6 OF GRADE AS REQUIRED RISER AT OUTLET TEE TO GRADE WITH SECURED COVER INLET FROM PUMP_ CHAMBER (SEE DETAIL AA) 4" PVC PIPE H �� 1/4"0 HOLE AT -8.7 MIN. SLOPE 6" MIN (SCH. 40) 4" PVC }' 11.0f N C INVERT OF PIPE .02 - z :, SCH 40 ALARM DETAIL AA 19.3 14" MIN. 01 OPE 4.25 ON 18 7 18 45 0.67' BRING RISER TO WITHIN 6" OF GRADE INSPECTION PORT CHARCOAL ..�. , r FINISHED � 2' x GRADE 27 MIN. SLOPE LEVEL - PROVIDE 114 C.Y. OF Nl 1 CONCRETE TO FORM SLOPED 4 o OFF ZABEL FILTER � vo wor yo BOTTOM AND PUMP SUMP / WITHIN EXISTING TANK 6.8f USE MEYERS SRM4 4/10 HP SANITARY TEE PPO grvorQ�0 .00 \ SUBMERSIBLE SEWAGE PUMP, 2" SUPPORT LEG ' 0 0 0 0 0 0 0 0 �vprwprypr♦ 0-�vprw rV O'vprw 30" SOLIDS HANDLING CAPABILITY "o_ gro,,�r4„�o,' gr0 o Q�,00e0o g9v 46' V 25.5 �0 00 o a0 000 0o a o 000 00 EXISTING 1,000 GAL SEPTIC TANK Ij EXISTING TANK TO BE CONVERTED FOR USE 6" CRUSHED STONE AS A PUMP CHAMBER. PUMP AND CLEAN TANK. REMOVE EXISTING INLET AND OUTLET PROP. 1500 GALLON TEES. PROVIDE WATERTIGHT SEAL BETWEEN 2" SEPTIC TANK D -BOX DISCHARGE PIPE TANK. REMOVE EXISTING 4" 7 -OUTLETS DISCHARGE PIPE AND PROVIDE WATERTIGHT (NEW TANK AT FRONT OF HOUSE) I PLUG AT EXISTING OPENING. 2 -PLUGGED syFo ,: , r AN ELECTRICAL PERMIT IS REQUIRED .. LONG POND (GREAT POND) 12" i POND ELEVATION 11/30/16 8.2 FT i LONG POND, DRI VE I (PUBLIC - 40' WIDE) CB DH (FND) BENCH MARK TOP OF CB ELEV=24.48 APPROX. M.S.L. 36. Q 71 Z PUMP ALARM /LOCA noN N/F WISNIEWSKI MAP 68 LOT 165 ,320 LONG POND DRIVE GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. PUMP FLOW CALCULATIONS PUMPEO VaUME=99 GAL DRAINBACK VOLUME=24 GAL NET FORWARD FLOW=99 GAL -24 GAL=75 GAL CYCLES PER DAY = 220 GPD/75 GAL = 3 CYCLES PER DAY PUMP HEAD CALCULATIONS STATIC HEAD = 18.7'-7.5'=11.2' PUMP RATE = 33 GPM FRICTION LOSS = 2.8 FT TDH= 11.2+2.8=14 FT PUMP CHAMBER RESERVE CAPACITY (VOLUME & TIME) RESERVE CAPACITY AFTER ALARM = 2.25'x4'x8'x7.48 GAL/CF = 539 GAL 625 GAL- 220 GPD = 2.8 DAYS RESERVE CAPACITY PUMP CHAMBER - 1000 GAL SEPTIC TANK W/RISER TO GRADE ACCESSING PUMP - MUST BE MADE WATER TIGHT PUMP USE MEYERS SRM4 SEWAGE PUMP OR EQUAL 4/10 HP HANDLE 2" 0 SOLIDS RUN TIME PER PUMP CYCLE 99, GAL/33 GPM ='3 MIN CONTROL PANEL REQUIREMENTS SIMPLEX CONTROLLER WITH ALARM, MUST BE INSIDE BLDG - OFF -AUTO -ON SWITCH (MINIMUM 3 SWITCH SYSTEM) - ALARM WITH LIGHT AND BUZZER/BELL - ALARM SILENCE BUTTON MUST BE OUTSIDE - ALARM TEST SWITCH - ALARM ON SEPARATE CIRCUIT FROM PUMP FORCE MAIN - 2" 0 P.E. PIPE OR SCH. 40 PVC - FORCE MAIN TO HAVE AN UPWARD SLOPE (NO -SAGS) FROM PUMP CHAMBER TO D=BOX W DRAIN BACK CAPABILITY. PUMP CHAMBER BUOANCY CALCULATION TANK BASE ELEV=6.2 FT GROUNDWATER ELEV=10.5 FT SUBMERGED DEPTH=10.5 FT -6.2 FT=4.3 FT BUOYANT FORCE=4.3 FTx4.5 FTx8.5 FTx62.5 LB/CF=10280 LB TANK WEIGHT=8750 LB CONC. BALAST WEIGHT=0.5 CYx27 CF/CYx10 LB/CF=1890 LB SOIL COVER =4.5 FTx8.5 FTx 0.5 FTx 110 LB/CF=2100 LB TOTAL WEIGHT=8750 LB+1809 LB+2100 LB=12740 LB NET FORCE=12740 LB -10280 LB=2460 LB DOWN .60 16.37 x ' SRI ES 42.34' 40-QUICK4 STANDARD INFILTRATORS LEACH I N FIELD 12" MIN. COVER LEACHING FIELD X -SECTION PLAN& PROFILE 1. OWNS 114 uSE MURIEL E•WELDON TRUSTEE 2. DEED REFERENCE: BK 21101 w SOIL TE � T DATA vl J TP N 0. 1 d w o- 0" O w 30" LOCAL UPGRADE APPROVAL REQUEST ALLOW THE MAXIMUM COVER OVER THE SAS TO GO FROM 3 FEET TO 4.8fFT. THE VENT WILL MAKE THIS SYSTEM WORK FINE. i CONS TRUC TION NOTES 1. PUMP EXISTING CESSPOOLS, REMOVE OR CRUSH & FILL W/GRAVEL 2. PLACE NEW TANK & INSTALL A100 ZABEL'FILTER W/SUPPORT LEG J. EXCAVATE FOR SAS INSPECTION SCHEDULE B. 0. H. TO INSPECT STONE BENEA TH SEP TIC TANK. BO TTOM OF EXCA VA TION INSPEC TION TO BE WI TNESSED B Y B. 0. H. & ENGINEER B.O.H. TO INSPECT TANKS, DBOX, AND SAS PIPING. ENGINEER TO INSPECT AND CERTIFY PIPE INVERTS AND COMPONENTS, AND PREPARE AN AS -BUILT PLAN. 38" 46" 123" PERFORMED BY:! -- -- 42.3 32.6 23.6 38.0 36.0 22.7 44.4 34.2 34.7 45.4 23.2 33.8 41.7 28.9 iRMBERT W. CROWELL P.E. 1 CERTIFY THAT THIS PLAN CONFORMS TO TITLE 5 AND THE YARMOUTH B.O.H. REGULATIONS. PUMP TO BE EQUIPPED WITH AN ALARM LOCATED IN THE BUILDING WHICH IS POWERED BY A CIRCUIT SEPARATE FROM THE CIRCUIT TO THE PUMPS. CHILD PROOF COVER WATER TIGHT 24-30" DIA. JUNCTION BOX ACCESS MH TOP OF FDN 21.2 -PVC ELECTRICAL PIPE FLOAT HANGER 2"TO 4" TO PUMP CONTROLS XP% IN BUILDING DETACHABLE FLANGE „ POLY PROPELENE LIFTING LINE EXISTING BUILDING SEWER M, PROP.1500 GAL 4" SVC PIPE f FLOAT SWITCHES 2" F• SEPTIC TANK (CH. 40) -BRING RISERS TO WITHIN 6 OF GRADE AS REQUIRED RISER AT OUTLET TEE TO GRADE WITH SECURED COVER INLET FROM PUMP_ CHAMBER (SEE DETAIL AA) 4" PVC PIPE H �� 1/4"0 HOLE AT -8.7 MIN. SLOPE 6" MIN (SCH. 40) 4" PVC }' 11.0f N C INVERT OF PIPE .02 - z :, SCH 40 ALARM DETAIL AA 19.3 14" MIN. 01 OPE 4.25 ON 18 7 18 45 0.67' BRING RISER TO WITHIN 6" OF GRADE INSPECTION PORT CHARCOAL ..�. , r FINISHED � 2' x GRADE 27 MIN. SLOPE LEVEL - PROVIDE 114 C.Y. OF Nl 1 CONCRETE TO FORM SLOPED 4 o OFF ZABEL FILTER � vo wor yo BOTTOM AND PUMP SUMP / WITHIN EXISTING TANK 6.8f USE MEYERS SRM4 4/10 HP SANITARY TEE PPO grvorQ�0 .00 \ SUBMERSIBLE SEWAGE PUMP, 2" SUPPORT LEG ' 0 0 0 0 0 0 0 0 �vprwprypr♦ 0-�vprw rV O'vprw 30" SOLIDS HANDLING CAPABILITY "o_ gro,,�r4„�o,' gr0 o Q�,00e0o g9v 46' V 25.5 �0 00 o a0 000 0o a o 000 00 EXISTING 1,000 GAL SEPTIC TANK Ij EXISTING TANK TO BE CONVERTED FOR USE 6" CRUSHED STONE AS A PUMP CHAMBER. PUMP AND CLEAN TANK. REMOVE EXISTING INLET AND OUTLET PROP. 1500 GALLON TEES. PROVIDE WATERTIGHT SEAL BETWEEN 2" SEPTIC TANK D -BOX DISCHARGE PIPE TANK. REMOVE EXISTING 4" 7 -OUTLETS DISCHARGE PIPE AND PROVIDE WATERTIGHT (NEW TANK AT FRONT OF HOUSE) I PLUG AT EXISTING OPENING. 2 -PLUGGED syFo ,: , r AN ELECTRICAL PERMIT IS REQUIRED .. LONG POND (GREAT POND) 12" i POND ELEVATION 11/30/16 8.2 FT i LONG POND, DRI VE I (PUBLIC - 40' WIDE) CB DH (FND) BENCH MARK TOP OF CB ELEV=24.48 APPROX. M.S.L. 36. Q 71 Z PUMP ALARM /LOCA noN N/F WISNIEWSKI MAP 68 LOT 165 ,320 LONG POND DRIVE GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. PUMP FLOW CALCULATIONS PUMPEO VaUME=99 GAL DRAINBACK VOLUME=24 GAL NET FORWARD FLOW=99 GAL -24 GAL=75 GAL CYCLES PER DAY = 220 GPD/75 GAL = 3 CYCLES PER DAY PUMP HEAD CALCULATIONS STATIC HEAD = 18.7'-7.5'=11.2' PUMP RATE = 33 GPM FRICTION LOSS = 2.8 FT TDH= 11.2+2.8=14 FT PUMP CHAMBER RESERVE CAPACITY (VOLUME & TIME) RESERVE CAPACITY AFTER ALARM = 2.25'x4'x8'x7.48 GAL/CF = 539 GAL 625 GAL- 220 GPD = 2.8 DAYS RESERVE CAPACITY PUMP CHAMBER - 1000 GAL SEPTIC TANK W/RISER TO GRADE ACCESSING PUMP - MUST BE MADE WATER TIGHT PUMP USE MEYERS SRM4 SEWAGE PUMP OR EQUAL 4/10 HP HANDLE 2" 0 SOLIDS RUN TIME PER PUMP CYCLE 99, GAL/33 GPM ='3 MIN CONTROL PANEL REQUIREMENTS SIMPLEX CONTROLLER WITH ALARM, MUST BE INSIDE BLDG - OFF -AUTO -ON SWITCH (MINIMUM 3 SWITCH SYSTEM) - ALARM WITH LIGHT AND BUZZER/BELL - ALARM SILENCE BUTTON MUST BE OUTSIDE - ALARM TEST SWITCH - ALARM ON SEPARATE CIRCUIT FROM PUMP FORCE MAIN - 2" 0 P.E. PIPE OR SCH. 40 PVC - FORCE MAIN TO HAVE AN UPWARD SLOPE (NO -SAGS) FROM PUMP CHAMBER TO D=BOX W DRAIN BACK CAPABILITY. PUMP CHAMBER BUOANCY CALCULATION TANK BASE ELEV=6.2 FT GROUNDWATER ELEV=10.5 FT SUBMERGED DEPTH=10.5 FT -6.2 FT=4.3 FT BUOYANT FORCE=4.3 FTx4.5 FTx8.5 FTx62.5 LB/CF=10280 LB TANK WEIGHT=8750 LB CONC. BALAST WEIGHT=0.5 CYx27 CF/CYx10 LB/CF=1890 LB SOIL COVER =4.5 FTx8.5 FTx 0.5 FTx 110 LB/CF=2100 LB TOTAL WEIGHT=8750 LB+1809 LB+2100 LB=12740 LB NET FORCE=12740 LB -10280 LB=2460 LB DOWN .60 16.37 x ' SRI ES 42.34' 40-QUICK4 STANDARD INFILTRATORS LEACH I N FIELD 12" MIN. COVER LEACHING FIELD X -SECTION PLAN& PROFILE 1. OWNS 114 uSE MURIEL E•WELDON TRUSTEE 2. DEED REFERENCE: BK 21101 w SOIL TE � T DATA vl J TP N 0. 1 d w o- 0" O w 30" LOCAL UPGRADE APPROVAL REQUEST ALLOW THE MAXIMUM COVER OVER THE SAS TO GO FROM 3 FEET TO 4.8fFT. THE VENT WILL MAKE THIS SYSTEM WORK FINE. i CONS TRUC TION NOTES 1. PUMP EXISTING CESSPOOLS, REMOVE OR CRUSH & FILL W/GRAVEL 2. PLACE NEW TANK & INSTALL A100 ZABEL'FILTER W/SUPPORT LEG J. EXCAVATE FOR SAS INSPECTION SCHEDULE B. 0. H. TO INSPECT STONE BENEA TH SEP TIC TANK. BO TTOM OF EXCA VA TION INSPEC TION TO BE WI TNESSED B Y B. 0. H. & ENGINEER B.O.H. TO INSPECT TANKS, DBOX, AND SAS PIPING. ENGINEER TO INSPECT AND CERTIFY PIPE INVERTS AND COMPONENTS, AND PREPARE AN AS -BUILT PLAN. 38" 46" 123" NO GROUND WATER ENCOUNTERED FERC TESTS PERFORMED BY:! !SOIL DEPTH 3. SOIL SOIL 4. SOIL 21.20 HOR. TEXTURE COLOR MOTTLING OTHER FILL -- THERE ARE NO KNOWN WETLANDS WITHIN 100' OF THE PROPOSED I -- NO MOTTLINGVERY SEWAGE ABSORPTION SYSTEM. .Ab .SANDY LOAM 1 OYR4/1 VERY FINE Bb- .SANDY LOAM 10YR5/8 FINE C COARSE SAND 2 5Y6/8 SIN IOSE AIN 16.70 9. THIS PROPERTY FALLS WITHIN A ZONE II WELL PROTECTION AREA, 21,0 16.37 NO GROUND WATER ENCOUNTERED FERC TESTS PERC # PERFORMED BY:! PG 278 DEPTH 3. ASSESSORS: MAP 68 LOT 164 11-30-16 4. RC ZONE, AQUIFER PROTECTION OVERLAY DISTRICT 21.20 5. THIS LOT DOES NOT FALL IN A FLOOD PLAIN AS SHOWN ON S.R.PHINNEY ROBERT CROWELL 19.30 COMMUNITY PANEL NO. 25001CO587J 07-16-2014. 2 MPI 6. THERE ARE NO KNOWN WETLANDS WITHIN 100' OF THE PROPOSED AMY von HONE , 111-30-161 SEWAGE ABSORPTION SYSTEM. 18.45 7. THERE ARE NO KNOWN POTABLE WELLS LOCATED WITHIN 200' OF THE D -BOX INLET 16.77 PROPOSED LEACHING FACILITY. GARBAGE GRINDER NOT ALLOWED 8. THERE ARE NO KNOWN IRRIGATION WELLS LOCATED WITHIN, 200' OF 17.04 DESIGN PERC RATE: 2 MPI THE PROPOSED LEACHING FACILITY. 16.70 9. THIS PROPERTY FALLS WITHIN A ZONE II WELL PROTECTION AREA, 21,0 16.37 AS SHOWN ON DEP-TITLE V SETBACK AREAS MAP. MIN. LEACHING AREA= 550 GPD/0.74 GPD/SF= 743 SF 10. THIS DESIGN DOES REQUIRE VARIANCES TO TITLE 5 (310 CMR 15.00) 18,5 LEACHING AREA: OR THE YARMOUTH SUPPLEMENTAL REGULATIONS. 5.2' . 11. TOPOGRAPHIC DETAIL, NATURAL AND MAN MADE SURFACE FEATURES ADJUSTED GROUNDWATER 10.50 ARE BASED ON AN ON GROUND SURVEY BY S.R.PHINNEY & CROWELL 17 8 ENGINEERING. 12. THERE ARE NO EASEMENTS FOR THIS PROPERTY. 16.8 13. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH 1" WASHERS., 10.8 TOTAL LEACHING AREA= GENERAL NOTES 1. ALL ELEVATIONS REFER TO AN ASSUMED BENCH MARK (APPROX. NGVD) SEE PLAN FOR LOCATIONS PERC # PERFORMED BY:! DATE DEPTH RATE -- 11-30-16 WITNESSED BY: TOP OF FOUNDATION 21.20 21.20 1 S.R.PHINNEY ROBERT CROWELL 19.30 46" 2 MPI SEPTIC TANK INLET 18.70 AMY von HONE , 111-30-161 OUTLET 18.45 DEEP HOLES TEST PIT # PERFORMED BY: DATE 1 WITNESSED BY: 1 S.R. PH NNEY 11-30-16 AMY voin HONE THE CORRECTION FOR THE GROUNDWATER IS 2.3 FEET. THE POND ELUEVATION WAS 8.2 FEET. 8.2-I-2.3=70.5 GROUNDWATER ELEVATION fSUNROOM I I MASTER B£DRM LIVING RM FAM/LY RM KITCHEN GARAGE FRONT ENTRY BATH RM BED TRM j i FIRST FLOOR 1 ARM GAME RM CARD ROOM UTILITY RM BAR STORAGE DESIGN DATA ELEVATIONS DESIGN AS -BUILT SINGLE FAMILY RESIDENCE TOP OF FOUNDATION 21.20 21.20 EXISTING 5 -BEDROOM INV @ FOUNDATION 19.30 19.30 5 -BEDROOM DESIGN SEPTIC TANK INLET 18.70 18.20 DESIGN FLOW 5 x 110 GPD/BDRM = 550 GPD OUTLET 18.45 17.95 550 GPD x 200% =1100 GAL USE 1500 GAL TANK D -BOX INLET 16.77 17.21 GARBAGE GRINDER NOT ALLOWED OUTLET 16.60 17.04 DESIGN PERC RATE: 2 MPI TOP OF CHAMBER 16.70 17.16 CLASS I SOIL TYPE, LTAR = 0.74 GPD/SF INV @ INFILTRATOR 16.37 16.83 MIN. LEACHING AREA= 550 GPD/0.74 GPD/SF= 743 SF BOTTOM OF CHAMBER,',, 15.70 16.16 LEACHING AREA: GROUNDWATER SEPERATION 5.2' . 5.66' USING INFILTRATOR QUIK4'S ADJUSTED GROUNDWATER 10.50 10.50 743 SF/4.72 SF/LF= 157.5 FT 157.5 FT/4FT/UNIT = 39.4 UNITS USE 5 -ROWS OF 8 = 40 UNITS TOTAL LEACHING AREA= 40 UNITS x 4 FT x 4.72 SF/FT=755 S.F. LEACHING RATE= 755 S.F. x 0.74 GPD/SF=558 GPD BASEMENT FLOOR PLANS I JUN' 2 8'2017 HEALTH DEPS f i 2. ALL CONSTRUCTION SHALL CONFORM TO 310 CMR 15.00, TITLE V AND THE REGULATIONS OF THE YARMOUTH BOARD OF HEALTH. 3. THIS PLAN DOES NOT WARRANT OR IMPLY ANY SUBSURFACE SOIL CONDITIONS OTHER THAN THOSE OBSERVED AT THE IMMEDIATE TEST PIT LOCATIONS. IF UNSUITABLE MATERIAL IS ENCOUNTERED, ALL CONSTRUCTION SHALL CEASE, AND THE DESIGN ENGINEER SHALL BE CONTACTED IMMEDIATELY. 4. ALL TANKS, D -BOXES, AND CHAMBERS SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED STABLE BASE OF CRUSHED STONE. 5. IF THE D -BOX IS DOSED OR THE INLET SLOPE EXCEEDS 87a, AN INLET TEE SHALL BE REQUIRED. 6. AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED TO MINIMIZE EROSION. THE AREA OVER THE SYSTEM SHALL BE GRADED TO A MINIMUM OF 2% SLOPE TO PROVIDE POSITIVE SURFACE DRAINAGE. 7. THIS PLAN SHALL, NOT BE USED FOR THE REPRODUCTION OF PROPERTY LINES, NOR SHALL IT BE USED' AS A MORTGAGE PLOT PLAN OR TITLE SURVEY. CONFORMANCE TO LOCAL BYLAWS SHALL BE DETERMINED BY THE OWNER PRIOR TO CONSTRUCTION. 8. THE OWNER IS RESPONSIBLE FOR THE DETERMINATION OF THE LOCATIONS OF ALL BURIED UTILITIES. 9. FOR PROPER PERFORMANCE, THE SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND PUMPED WHEN THE TOTAL DEPTH OF SOLIDS EXCEEDS 1/4 THE LIQUID DEPTH OF THE TANK. 10. ANY ALTERATIONS MUST BE REPORTED TO THE DESIGN ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 11. THE SYSTEM MUST BE INSPECTED BY THE BOARD OF HEALTH OR ITS AGENT AND BE CERTIFIED BY THE DESIGN ENGINEER. 12. NO STRUCTURE MAY BE CONSTRUCTED OVER THE RESERVE AREA. 13. CONSERVATION COMMISSION APPROVAL MAY BE REQUIRED. 14. THE SYSTEM SHALL BE VENTED AS SHOWN. 15. SEE 310 CMR 15.255 FOR FILL SPECIFICATIONS. SEE 310 CMR 15.247 FOR AGGREGATE SPECIFICATIONS. BOARD OF HEALTH CONDITIONS 1. THE PROPOSED SEWAGE DISPOSAL SYSTEM SHALL MEET THE APPLICABLE TITLE 5 WETLANDS SETBACKS AS SET FORTH BY THE HEALTH DEPARTMENT. 2. A "WORK LIMIT" LINE SHALL BE ESTABLISHED WITH EROSION CONTROLS (LE STRAW BALES, STAKED FILTER FABRIC, BARK MULCH, "SILT SACKS," PRODUCTS MADE WITH RICE STRAW, AND OTHER WEED -FREE PRODUCTS OR APPROVED BY THE COMMISSION.) HAY BALES ARE NOT ALLOWED. IT IS THE APPLICANT'S RESPONSIBILITY TO IMPLEMENT AND MAINTAIN APPROPRIATE AND ADEQUATE EROSION CONTROLS MEASURES THROUGHOUT THE CONSTRUCTION PROCESS. 3. NO WORK OF ANY KIND SHALL OCCUR ON THE RESOURCE AREA SIDE OF THE WORK LIMIT LINE. THIS LINE SHALL BE ESTABLISHED PRIOR TO ANY CONSTRUCTION OR WORK. 4. ALL IMPORTED FILL SHALL BE CLEAN AND NOT CONTAIN ANY FOREIGN DEBRIS SUCH AS CEMENT, BITUMINOUS CONCRETE, RUBBER, METAL, TRASH, -BOULDERS,---- ETC. BOULDERS,- --ETC. 5. DEBRIS, INCLUDING LITTER, SHALL BE PICKED UP IMMEDIATELY. ANY EXCESS MATERIAL THAT IS EXCAVATED FROM THE JOB SITE SHALL BE DISPOSED OF AT A LOCATION APPROVED BY THE CONSERVATION ADMINISTRATOR OR IN A COVERED DUMPSTER. NO DEBRIS SHALL BE ALLOWED IN A WETLAND OR WATERWAY. 6. WASHING OF EQUIPMENT/TOOLS SHALL BE DONE OFF-SITE OR HANDLED IN A MANNER APPROPRIATE BY THE CONSERVATION ADMINISTRATOR. 7. NO EQUIPMENT SHALL BE REFUELED, NOR SHALL FUEL BE STORED WITHIN 100 FEET OF A RESOURCE AREA. 8. THE CESSPOOL IS TO BE PUMPED DRY, THE CONNECTION BROKEN, AND FILLED WITH CLEAN SAND. 9. ANY AREA THAT IS DISTURBED DURING CONSTRUCTION SHALL BE REVEGETATED IMMEDIATELY OR AS SOON AFTER AS THE GROWING SEASON COMMENCES. PERMANENT STABILIZATION SHALL BE CARRIED OUT IN ORDER TO MINIMIZE EROSION. THIS DOCUMENT HAS BEEN PROVIDED TO THE CLIENT WITH CERTAIN CAVEATS AND VERBAL WARNINGS CONCERNING ITS USE AND RELIABILITY. THIS DOCUMENT WAS INTENDED FOR A SPECIFIC USE DURING A SPECIFIC TIME PERIOD. IF THIS DOCUMENT IS IN THE POSSESSION OF ANY PERSON THAN THE CLIENT OR ITS AUTHORIZED AGENT, THE SEAL, SIGNATURE, AND CERTIFICATION ARE REVOKED. RELIANCE ON THE DOCUMENT BY ANY PERSON AFTER DEC 2018 COULD LEAD TO SERIOUS DAMAGES OR UNEXPECTED CONSEQUENCES.