HomeMy WebLinkAboutEngineered Plan - 2017FL -100.75 I N ACCESS COVERS MUST._BE WITHIN 9" MINIMUM. 6" OF FINISH GRADE 3' MAXIMUM COVER FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE OR F I L TER FABRIC " oIAM PIPE 3/4 - l 1/2 DIA. 98.9 98.03 2T DOUBLE WASHED STONE 99.15 GAS 98.2 98. 0 BAFFLE 3 OUTLET 2-500 GAL LEACHING CHAMBERS 'Q D -BOX W14' STONE AROUND. 12.8'• x 33'1 x 2'd 1500 GAL H-20 SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE L OCUS MAP 0 /0 20 40 INVERT ELEVATIONS: INVERT AT BUILDING: 99.35 INVERT IN SEPTIC TANK: 99.15 INVERT OUT SEPTIC TANK: 98.9 INVERT IN DIST. BOX: 98.2 INVERT OUT DIST. BOX: 98.03 INVERT IN LEACH CHAMBER: 98.0 BOTTOM OF LEACH CHAMBER: 96.0 ADJUSTED GROUND WATER: NIA OBSERVED GROUND WATER: NIA BOTTOM OF TEST HOLE *I: 91.0 BASEMENT FLOOR PLAN a CB CONCRETE BOUND —W WATER L I NE O HYDRANT G GAS LINE OHW— 'OVER HEAD WIRES LOAMY -LIGHT POST --E— UNDERGROUND ELECTRIC LINE —T— UNDERGROUND TELEPHONE LINE —CTV— UNDERGROUND CABLEVISION LINE + 40.4 SPOT ELEVATION .-.-40 ------- EXI STING CONTOUR 40 PROPOSED CONTOUR DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 G.P.D. X 200% - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REOUIREO: DESIGN PERC RATE ( 5 MI NII NCH SOIL TEXTURAL CLASS - I EFFL UENT L OAD I NG RA TE - 0. 74 GPDISF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W14' STONE AROUND. A-608 S.F. 608 S. F. x 0. 74 - 448 G. P. D. SOIL TEST PIT DA TA INDICATES INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER /0/.0 120. NO WATER 91.0 DATE: JUNE 21. 2017 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE. C 2 MI NII NCH GENERAL NO TES : I. THIS PLAN I S FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VER T I CAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR L OCA T I ON OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. CONNECTION AT THE DWELLING TO BE MADE TO THE EXISTING CAST IRON OUTLET PIPE. CONTRACTOR TO VERIFY THE ELEVATION OF THE END OF THE CAST IRON PIPE PRIOR TO INSTALLATION OF THE SEPTIC TANK. *�jHOFMAST -mow TE R ANI y t" A'NER No. 33721 Lv,w vv 1 S E7P T / C SYS TEM DES/0N SO "E -ME -ON DR / VE . MAP Oa PARCEL a0 WEST YARMOUTH. MA. PREPARED FOR .JOHN HENDE-R S ON SCALE : / " - 20 ' JULY / 7 . 2017 STEPHEN A. HAAS ENGINEERING, INC P . 0 Box 16 South Dennis, MA 02660 (50B) 362-8132 JOB NO: 17-020 TP l 0. HORIZON TEXTURE COLOR A LOAMY IOYR SAND 3/3 5" -------------------- B LOAMY IOYR SAND 416 24' -------------------- C / MEDIUM IOYR SAND 6/6 /0/.0 120. NO WATER 91.0 DATE: JUNE 21. 2017 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE. C 2 MI NII NCH GENERAL NO TES : I. THIS PLAN I S FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VER T I CAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "DIG -SAFE 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR L OCA T I ON OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. CONNECTION AT THE DWELLING TO BE MADE TO THE EXISTING CAST IRON OUTLET PIPE. CONTRACTOR TO VERIFY THE ELEVATION OF THE END OF THE CAST IRON PIPE PRIOR TO INSTALLATION OF THE SEPTIC TANK. *�jHOFMAST -mow TE R ANI y t" A'NER No. 33721 Lv,w vv 1 S E7P T / C SYS TEM DES/0N SO "E -ME -ON DR / VE . MAP Oa PARCEL a0 WEST YARMOUTH. MA. PREPARED FOR .JOHN HENDE-R S ON SCALE : / " - 20 ' JULY / 7 . 2017 STEPHEN A. HAAS ENGINEERING, INC P . 0 Box 16 South Dennis, MA 02660 (50B) 362-8132 JOB NO: 17-020