Loading...
HomeMy WebLinkAboutEngineered Plan - 2017U I` L0 t\ O N Ml U AVVF> / RO 50.1 — Hydrant Vv ..... Spindle — Catch / — ® Ba§in 53.3 48 �/ I Water cs: 00• 54.1 48.6 — Gate 0. ::•:I 53.9 52.6 52 )2 \ 521 :.; ;•:>>: ; :y"':::.::.:::: , V.53.6 0- 53.0 .....531• Vit,, A \ � Paved \ I' \ Drive \ Z \ \ m \ 53.7 53.7 / 538 5,313 E / BENCHMARK: EI. 53.1 (Assumed Datum) SURVEY NAIL SET \ Stone \ Drive \ 53�5 539 o �— SCALE.• 7 "= 20' 0' 20' 40' 60' 538 54.0 \� 53.9 Wo\k ;k• 54.0 / �W e1\8 9 SOF P 0t\o Co �ce ck B\o/ / S �1�a'21 N OF U480 Se�pck V'°� RICHARD A!') , % ' r ��� � � J.JU S G T -4NITARIN raP �— PUMP 8 REMOVE EX/ST/NG LEACH P1 �L�e B CONTAMINATED SOILS I w1 rHIN 5' OF PROP. SAS ,A0G 5 LOCUS • 52 Pond PROPOSED LEACH/NG AREA 30.3' X 9.6' x 2.0' (H-10) LOCATION MAP Assessors Map 134 54.1 RE7CEIVE—D Parcel 77 PUMP & RETA/N EX/ST/NG FFg..017 Deed: Bk.21285, Pg.248 1000 -GALLON SEPTIC TANK I HEALTH DEPT. Bath Bedrm Storage Living Bath Rm 54.2 `� cl cl NW Lndry o_ 1t Bedrm Dining Kitchen Yarmouth Health Department Rm Bedrm M - PZ�VED 1 ST FLOOR ame Date Closet & Mechanicals Partially gN Finished Mechanicals Finished Slab Rm LOT 21 Partially below grade PLAN BOOK 207 Finished PAbE 57 Workshop BASEMENT EXISTING FLOOR LAYOUT MgRANENGINEERING ASS OC.,MC 508-432-2878 IB), H, SEPTIC SYSTEM DESIGN PLAN IN YARMOUTH Prepared For: Dublin Construction 777 ROUTE 6A YARMOUTH PORT MA Sht: 10 f2 PROJECT: 76-242 1 SCALE: 7 "= 20' DATE: 77175176 10'f -- T.O.F. Exist. ELEV. 50.9 �- --� filter fabric 10' 11' max or ACCESS MANHOLES TO WITHIN 1/8" to 1/2" 3"-(z" OF FINISHED GRADE doubstoneshed .� ELEV.- 53.00 MAX. �— SEPTIC TANK Replace Tees If corroded SYSTEM PROFILE SET NEW EXIT LINE Not to Scale SAS CONSTRUCTION DETAIL 500 GAL. LEACHING CHAMBER STONE T:Y�� (— ------ 24' 9.6 0 0 0 Provide (2) covers within 3" of finish grace 4 ' 2.4 8.5' 8.5' 8.5' 2.4 1-6 30.3' 5.05' 30.3' x 9.6' x 2.0'deep � ELEV. 42.15 500 Gal. Chamber 8c Stone Btm. T.H. H-10 LEACHING FACILITY SEPTIC SYSTEM NOTES - CONTACT OFFICE (508)-432-2878 A MINIMUM OF 48 HOURS PRIOR TO START OF PROJECT. - EXISTING SEWER ELEVATION IS TO BE VERIFIED PRIOR TO THE INSTALLATION OF NEW SYSTEM COMPONENTS. - EXISTING 1000 GALLON SEPTIC TANK IS TO BE PUMPED AND RETAINED. INLET & OUTLET TEES ARE TO BE REPLACED IF CORRODED. INSTALL RISERS TO WITHIN 6" OF FINISH GRADE. PUMP & REMOVE EXISTING LEACH PIT AND CONTAMINATED SOILS WITHIN 5' OF PROPOSED SAS. - UNSUITABLE SOILS ARE TO BE REMOVED, IF ENCOUNTERED BELOW EL. 49.2, FOR 5' AROUND THE LEACHING AREA AND REPLACED WITH TITLE -5 FILL SOIL. - ALL COMPONENTS ARE TO MEET TITLE 5 MATERIAL & CONSTRUCTION REQUIREMENTS. - SYSTEM COMPONENTS ARE TO BE SET ON A STABLE, COMPACTED BASE. - DISTRIBUTION BOX EXIT LINES ARE TO BE SET LEVEL FOR THE FIRST 2'. - DESIGN ENGINEER IS TO VERIFY SOILS OF ALL SAS EXCAVATIONS BEFORE SYSTEM INSTALLATION. - DESIGN ENGINEER IS TO VERIFY SYSTEM INSTALLATION (LOCATIONS & ELEVATIONS) PRIOR TO BACKFILLING. - COMPONENTS ARE TO BE WITHIN 3' OF FINISH GRADE & ARE TO HAVE A MINIMUM OF 1' OF SOIL COVER. ACCESS MANHOLES ARE TO BE WITHIN (3"-6") OF FINISHED GRADE. - ALL POST CONSTRUCTION LANDSCAPING DETAILS ARE TO BE BETWEEN INSTALLER AND PROPERTY OWNER OR AGENT. TEST HOLE l El. 52.90 Elev. I% SET 0 et Iv I first 50 Horizon '`2ELEV. „ 4" to 1 j IdLble I� 51.73 0- 14 " HTM .. ::::::::::. -0 NIA : COVER 50 0 ...... washedELEV ne10" Fin e 7.5YR5/6 14"l� ADD GAS -� 000c o000 Medium Sand singleSe grain 68-129" BAFFLE000e==0000 �000 oo00000 2.5Y612 Loose d7 1 19 ' 4 6 ELEV. 49. oe000e0000c oe00000000 ' Retain Existing "' 0000000000c o0000000vo ... ....... ELEV. 47.20 1000 GAL. D—BOX 2 4, H-10 3-500 Gal Chambers MI 2 4, 25 5'I -e SEPTIC TANK Replace Tees If corroded SYSTEM PROFILE SET NEW EXIT LINE Not to Scale SAS CONSTRUCTION DETAIL 500 GAL. LEACHING CHAMBER STONE T:Y�� (— ------ 24' 9.6 0 0 0 Provide (2) covers within 3" of finish grace 4 ' 2.4 8.5' 8.5' 8.5' 2.4 1-6 30.3' 5.05' 30.3' x 9.6' x 2.0'deep � ELEV. 42.15 500 Gal. Chamber 8c Stone Btm. T.H. H-10 LEACHING FACILITY SEPTIC SYSTEM NOTES - CONTACT OFFICE (508)-432-2878 A MINIMUM OF 48 HOURS PRIOR TO START OF PROJECT. - EXISTING SEWER ELEVATION IS TO BE VERIFIED PRIOR TO THE INSTALLATION OF NEW SYSTEM COMPONENTS. - EXISTING 1000 GALLON SEPTIC TANK IS TO BE PUMPED AND RETAINED. INLET & OUTLET TEES ARE TO BE REPLACED IF CORRODED. INSTALL RISERS TO WITHIN 6" OF FINISH GRADE. PUMP & REMOVE EXISTING LEACH PIT AND CONTAMINATED SOILS WITHIN 5' OF PROPOSED SAS. - UNSUITABLE SOILS ARE TO BE REMOVED, IF ENCOUNTERED BELOW EL. 49.2, FOR 5' AROUND THE LEACHING AREA AND REPLACED WITH TITLE -5 FILL SOIL. - ALL COMPONENTS ARE TO MEET TITLE 5 MATERIAL & CONSTRUCTION REQUIREMENTS. - SYSTEM COMPONENTS ARE TO BE SET ON A STABLE, COMPACTED BASE. - DISTRIBUTION BOX EXIT LINES ARE TO BE SET LEVEL FOR THE FIRST 2'. - DESIGN ENGINEER IS TO VERIFY SOILS OF ALL SAS EXCAVATIONS BEFORE SYSTEM INSTALLATION. - DESIGN ENGINEER IS TO VERIFY SYSTEM INSTALLATION (LOCATIONS & ELEVATIONS) PRIOR TO BACKFILLING. - COMPONENTS ARE TO BE WITHIN 3' OF FINISH GRADE & ARE TO HAVE A MINIMUM OF 1' OF SOIL COVER. ACCESS MANHOLES ARE TO BE WITHIN (3"-6") OF FINISHED GRADE. - ALL POST CONSTRUCTION LANDSCAPING DETAILS ARE TO BE BETWEEN INSTALLER AND PROPERTY OWNER OR AGENT. TEST HOLE l El. 52.90 Elev. I Depth Horizon Texture Color Other 51.73 0- 14 " HTM Fill NIA NIA 14-68" C1 Fin e 7.5YR5/6 se 47.23 Medium Sand singleSe grain 68-129" C2 Fine- 2.5Y612 Loose d7 1 19 VeryFine Sand single groin Btm El. 42.15 No Groundwater Found Date: 11/17/16, Performed By: Rick Judd, SE, Witness: Amy von Hone, R.S., HA Perc. at 60" (24 -gallons in 11:12) Percolation rate <2 min/inch SYSTEM DESIGN Design Flow: 3 bedrooms @ 110 gal/day = 330 gal. Septic Tank: 330 gal. x 200% = 660 gal. Retain Existing 1000 Gal. Tank Leaching Facility: 9.6'x30.3'x2'deep Chamber and Stone SAS Bottom: 9.6'x 30.3' x 0.74 Gal/sf= 215 Gal Sides: (9.6'+30.3')x2'x2xO.74G61/sf=118 Gal TOTAL = 333 Gal Note: Garbage disposal is not permitted with this design.